PAGE 36
OCT-16
20. MIXING THE FLUID IN THE TANK
The fluid is mixed with:
- The return hose
- Hydraulic mixers
The mixing depends on the pump rpm - higher rpm more
effect.
The recommended pressure for the mixer is between 10 and
20 bar. Raise the pressure in the beginning of the work, and
when you stopped working for a while. The mixer can be
closed with the valves on the picture (left).
Mixer can be shut on and off with the ball valve
If the nozzles in the mixers stop, then the nozzle
needs to be cleaned or replaced. To do that, pull the
fitting fork out, and then pull the mixer out from
stirrer's body. Watch the seals when you put it
together again.
21. SUCKING FILTER
The sucking filter protects the pump from hard
particles. It is placed under the tank.
Cleaning of the filter:
Before you dismantle the filter, put a bucket under
it- to catch the fluid.
-
Make sure that no fluid is in the tank, or
close the valve near the filter (on the
picture).
-
Unwind the filter lid.
-
Clean the net with clean water and a soft
brush.
-
Clean the seals seats.
-
Place the net and the seal, and screw the lid on.
-
Open the valve.
-
Remove the bucket with fluid.
When to clean the filter?
- After the test spraying.
- After the work.
- When the pressure falls for no reason.
Empty the filter before the winter.