PAGE 50
OCT-16
1) Set status through key 1.
2) Press OK to save, or ESC to quit without saving.
28.1.4 ALARMS
PRESSURE ALARM
Set minimum and maximum pressure thresholds for alarm message.
1) Open Alarm menu (Setup menu > Alarms). Minimum and maximum pressure alarms
are set in the same way. The display will show the current setting below the selected item.
Press OK to edit the selected menu item.
2) To activate the alarm, press keys above at the same time until message OFF goes off
and pressure alarm value is displayed instead. Carry out the same procedure to disable
alarm again.
3) Set alarm value:
A) Press to move through digits
B) Press a few times to edit the highlighted digit
C) Press to save changes, or
D) Press to quit the page without confirming changes.