background image

LIMITED WARRANTY

All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the 

date of purchase. Decorative finishes warranted for one year. We will replace at no costs goods that prove defective provided we are 

notified in writing of such defect and the goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly 

maintained and used in accordance with instructions. We shall not be responsible for any labor charges or any loss, injury or damages 

whatsoever, including incidental or consequential damages. The sole and exclusive remedy shall be limited to the replacement of the 

defective goods. Before installation and use, the purchaser shall determine the suitability of the product for his intended use and the 

purchaser assumes all risk and liability whatever in connection therewith. Where permitted by law, the implied warranty of merchantabil

-

ity is expressly excluded. If the products sold hereunder are “consumer products,” the implied warranty of merchantability is limited to a 

period of three years and shall be limited solely to the replacement of the defective goods. All weights stated in our catalogs and lists are 

approximate and are not guaranteed.

AquaSense

®

Z6920-XL and Z6922-XL Series

Sensor-Operated Lavatory Faucets for Battery, 

Plug-In, or Hardwire Installations, Connected 

Installation, Operation, Maintenance,

and Parts Manual

Patented and Patents Pending

WARNING

: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

ADVERTENCIA: 

Cáncer y daño reproductivo - www.P65Warnings.ca.gov

AVERTISSEMENT: 

Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov

Z6920-XL

Z6922-XL

NOTICE: READ ENTIRE MANUAL PRIOR TO INSTALLING PRODUCT.

Summary of Contents for AquaSense Z6920-XL Series

Page 1: ... the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantabil ity is expressly excluded If the products sold hereunder are consumer products the implied warranty of merchantability is limited to a period of three years and shall be limited solely to the replacement of the defective goo...

Page 2: ...This Page Intentionally Left Blank ...

Page 3: ... W1 As Shown Z6920 XL W1 As Shown Endpoint W1 Only Y Cable W1 Only CWB DC Adapter Aerator and Key Electronics Box with Ceramic Valve Filter O Ring for Base Spout Assembly Spout Assembly Aerator and Key Electronics Box with Ceramic Valve Shank Mounting Kit Base Gasket Filter ...

Page 4: ...h Solenoid Shank Mounting Kit Base Gasket Aerator and Key Electronics Box with Solenoid Filter Spout Assembly Batteries Batteries Filter O Ring for Base Hydrogenerator Hydrogenerator Sensor Inline Connector Sensor Inline Connector Required Tools Adjustable Wrench Phillips Head Screwdriver Spout Assembly 3 32 M3 Hex Key Wrenches Supplied ...

Page 5: ...ll not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this devic...

Page 6: ...ter supply line or pre tempered water supply line Installer Servicer should not use pipe dope or teflon thread sealant anywhere on this product most notably threads and connection points Care shall be taken when installing this product to prevent marring of any exposed or decorative surfaces Be sure the sink lavatory basin is clear from any objects upon making the sensor to electronics connection ...

Page 7: ...nfigurations NOTE Before installation turn off water supplies to existing faucet and remove faucet if replacing an existing device Clean the faucet basin and clear away debris Flush all supply lines before connecting the faucet Failure to do so may result in debris clogging the inlets and or internal control and mixing valve of the faucet 1 Carefully screw aerator into spout using included tool Ta...

Page 8: ...and AC adapter 3b Optional HW6 Hardwired 6V version Connect supplied inline connector and hardwire adapter When securing the CWB wires to the screw terminals on HW6 unit the BLACK WITH DASHED MARKINGS should be connected to the Positive terminal and the SOLID BLACK wire should be connected to the Negative terminal 4 Turn on water supply ies ACA CWB HW6 Endpoint Electronic Module Installation Instr...

Page 9: ...nd or power converter 2 Use 18 AWG for interconnections B BL LA AC CK K W WH HIT ITE E S ST TR RI IP PE E F FA AU UC CE ET T F FA AU UC CE ET T F FA AU UC CE ET T B B L L U U E E G G R R E E E E N N Y Y E E L L L L O O W W F F R R A A M M E E S S A A F F E E T T Y Y GROUN GROUND D P6000 P6000 H H W W 6 6 W W I I R R I I N N G G I IN N V V A A C C L L I I NE NE B B L L A A C C K K N N E E U U T T R...

Page 10: ...XXX Form No FV5 59 Electronics Module Installation Instructions HYD 5 Ensure sink is clear of tools debris and is in normal operating condition Remove protective film from sensor lens if needed 6 Turn on water supply ies 4 Tighten electronics module assembly with hydrogenerator to shank and connect water line s 1 Connect hydrogenerator A downstream of electronics module B and filter C to bottom of...

Page 11: ...in AC adapter to wall outlet 5 b Optional HW6 version Connect supplied inline connector and hardwire adapter When securing the CWB wires to the screw terminals on HW6 unit the BLACK WITH DASHED MARKINGS should be connected to the Positive terminal and the SOLID BLACK wire should be connected to the Negative terminal ACA BLUE GREEN YELLOW FRAME SAFETY GROUND P6000 HW6 WIRING IN VAC LINE BLACK NEUTR...

Page 12: ...ailure of the sensor and or power converter 2 Use 18 AWG for interconnections B BL LA AC CK K W WH HIT ITE E S ST TR RI IP PE E F FA AU UC CE ET T F FA AU UC CE ET T F FA AU UC CE ET T B B L L U U E E G G R R E E E E N N Y Y E E L L L L O O W W F F R R A A M M E E S S A A F F E E T T Y Y GROUN GROUND D P6000 P6000 H H W W 6 6 W W I I R R I I N N G G I IN N V V A A C C L L I I NE NE B B L L A A C C...

Page 13: ...battery module During initial installation use the supplied alkaline batteries During subsequent battery changes ONLY use alkaline batteries Do not mix alkaline and lithium batteries together During initial installation use the supplied lithium batteries During subsequent battery changes use either alkaline or lithium batteries however do not mix alkaline and lithium batteries together During serv...

Page 14: ...se any abrasive or chemical cleaners to clean the faucets Do not use any cleaners with an acid base If abrasives or chemicals are used it can lead to dulling of luster attacking of chrome plating or decorative finishes ONLY use mildly warm soapy water and then wipe the device dry with a clean soft towel or cloth Upon cleaning other areas of the restroom be sure the sensor lenses are protected from...

Page 15: ...gh as possible such as near the top of a wall Avoid obstructions Thick walls and reflective surfaces such as metal weaken the signal between the gateway and other devices The LoRa antenna is an omni directional antenna but for best results mount the device so the LoRa antenna is in a vertical position near the top of a wall We recommend conducting a site survey to test the signal strength in diffe...

Page 16: ...ection performance related to the sink material shape finish The faucet sensor sensitivity is configured during pack out but the mode can be changed upon installation to optimize the performance within the sink Sensor sensitivity and sensor detection Modes A B may be tried for various lighting conditions sink materials and shape Switch 7 controls the sensitivity On default is normal sensitivity fo...

Page 17: ... broken If yes then the electronic box needs replaced Micro processor has locked up Disconnect power Wait 10 sec onds Reconnect power Ghost Activation Sensor lens could be obstructed or environmental factors such as highly reflective surfaces and or bright sunlight conditions could be present Check clean sensor lens of any debris or buildup Remove reflective surfaces or adjust lighting conditions ...

Page 18: ... Check if protective film was removed from lens Check if protective film was removed from lens If it was not then remove it Water does not stop Electronic box connector cable has bent or broken pins Check to see if pins are missing bent or broken If yes then the electronic box needs to be replaced Ghost Activation Sensor lens could be obstructed or environmental factors such as highly reflective s...

Page 19: ...nitor s cables are connected to IR sensor and Faucet actuator electronics Restore proper electrical connection as needed Step 2 Test activate the faucet If problem persists see Faucet Troubleshooting section in this guide for other steps Status Good posted in plumbSMART and faucet actuates but usage event data not appearing in plumbSMART Charts Step 1 Verify gateway is powered and LoRa Status LED ...

Page 20: ...lity IT administrator to modify port rules to allow Zurn gateway to access the internet via local router If gateway model is ETH LTE visually verify SIM card is installed in designated slot on the side of gateway If unit has a SIM card then disconnect ethernet cable and power cycle the gateway and wait for unit to initialize and connect LORA LED should turn ON solid after initialization Step 4 If ...

Page 21: ...ons Filter and Mixing Valve Installation All Configurations Attach adapter or Braided Hose SSH here with MV and TMV 1 options Need to hold at pointed area by suitable wrench or by hand while applying torque to the supply hose nut Do not over torque the nut P6900 12BC Filter To Control Box SSH Option Supplied Adapter 3 8 Copper Tube By Others Mixing Valve MV ...

Page 22: ...service solenoid use Phillips head screw driver to remove the screws on both sides of the electronics box With screws removed the electronics box can slide off and allow access to the solenoid for service Accessing the Solenoid W2 HYD ...

Page 23: ...ing Kit P6900 43 Item 3B Z6922 Mounting Kit P6922 43 Item 4 Plug In Power Converter P6900 ACA Item 5 CWB Pigtail P6900 CWB Item 6 Filter Kit P6900 120BC Description Product No Item 7 Filter Screen P6900 MV 7 Item 8 Mixing Valve with Filter P6900 MV XL Item 9 Composite Mixing Valve Adapter P6900 MV ADAP Item 10 Ceramic Valve P6950 XL CV B L Item 11 4 Cast Cover Plate w Gasket P6900 CP4 Item 12 8 Ca...

Page 24: ... 42 WEDGE Item 13 Sensor Inline Connector P6950 XL DC Item 14 4 Cast Cover Plate w Gasket P6900 CP4 Item 15 8 Cast Cover Plate w Gasket P6900 CP8 Description Product No Item 1 5 3 8 Gooseneck Spout with Nut P6900 GB Item 2A Z6920 No Lead Spout Base with Sensor Assembly P6920 XL 2 Item 2B Z6922 No Lead Spout Base with Sensor Assembly P6922 XL 2 Item 3A Z6920 Mounting Kit P6900 43 Item 3B Z6922 Moun...

Page 25: ...unting Kit P6900 43 Item 3B Z6922 Mounting Kit P6922 43 Items 4 7 Smart Connected Faucet Retrofit Kit P6900 RK W1 Item 8 Filter Kit P6900 120BC Description Product No Item 9 Filter Screen P6900 MV 7 Item 10 Mixing Valve with Filter P6900 MV XL Item 11 Composite Mixing Valve Adapter P6900 MV ADAP Item 12 Ceramic Valve P6950 XL CV B L Item 13 4 Cast Cover Plate w Gasket P6900 CP4 Item 14 8 Cast Cove...

Page 26: ...20 Base Plate Gasket P6920 42 WEDGE Item 14 Sensor Inline Connector P6950 XL DC Item 15 4 Cast Cover Plate w Gasket P6900 CP4 Item 16 8 Cast Cover Plate w Gasket P6900 CP8 Description Product No Item 1 5 3 8 Gooseneck Spout with Nut P6900 GB Item 2A Z6920 No Lead Spout Base with Sensor Assembly P6920 XL 2 Item 2B Z6922 No Lead Spout Base with Sensor Assembly P6922 XL 2 Item 3A Z6920 Mounting Kit P...

Page 27: ...This Page Intentionally Left Blank ...

Page 28: ...TRIES LLC 511 W Freshwater Way Milwaukee WI U S A 53204 Ph 1 855 ONE ZURN Fax 919 775 3541 In Canada ZURN INDUSTRIES LIMITED 7900 Goreway Drive Unit 10 Brampton Ontario L6T 5W6 Ph 905 405 8272 Fax 905 405 1292 Rev A Date 09 07 21 C N No 143900 Prod Dwg No FV808 ...

Reviews: