FV637 Rev. A   3/26/2019
Page 4

   

 

2.2a. 

Optional ACA version: Connect supplied AC adapter to 

power port on electronics box.

2.2b. 

Optional HW6 (Hardwired 6V) version: Connect supplied 

inline connector and hardwire adapter.  When securing the CWB 
wires to the screw terminals on HW6 unit, the BLACK WITH 
DASHED MARKINGS should be connected to the Positive (+) 
terminal, and the SOLID BLACK wire should be connected to the 
Negative (-) terminal.

MJ unit (sold separately)
Note: Do not connect more than 8 solenoids to a single transformer

2.3. Tighten electronics module assembly to shank and connect 
water line(s).

2.4. Ensure that sink is clear of tools/debris and is in normal 
operating condition.
2.5. Turn on water supply(ies).  Water supply must be turned on in 
order for sensor to perform wet calibration step.

Do not engage the sensor for 30 seconds after the connection 
is made. The sensor will perform automatic calibration. 

-CWB

-HW6

-MJ

-HW6

18 AWG (MIN) 

MAX LENGTH 40’

ACA

Summary of Contents for Cumberland Series

Page 1: ...warranted for one year We will replace at no costs goods that prove defective provided we are notified in writing of such defect and the goods are returned to us prepaid at Sanford NC with evidence that they have been properly maintained and used in accordance with instructions We shall not be responsible for any labor charges or any loss injury or damages whatsoever including incidental or conseq...

Page 2: ...dequate water supply for each fixture Flush all water lines prior to making connections Required Tools Cumberland Series Faucet Package Contents Z6956 XL Prior to Installation Before installing your Zurn Cumberland Series Faucet the items listed below should already be installed on site Lavatory sink Drain Line Hot and cold water supply line or pre tempered water supply line Installer Servicer sho...

Page 3: ... washer and mounting nut and cover plate for versions that are included 1 3 Ensure that slot in plastic washer is facing forward 2 1 Assemble the electronics module NOTE Before installation turn off water supplies to existing faucet and remove faucet if replacing an existing device Clean the faucet basin and clear away debris Flush all supply lines before connecting the faucet Failure to do so may...

Page 4: ...K wire should be connected to the Negative terminal MJ unit sold separately Note Do not connect more than 8 solenoids to a single transformer 2 3 Tighten electronics module assembly to shank and connect water line s 2 4 Ensure that sink is clear of tools debris and is in normal operating condition 2 5 Turn on water supply ies Water supply must be turned on in order for sensor to perform wet calibr...

Page 5: ...t ac vate a er ini al installa on Sensor may not have had enough me to calibrate prior to a user or target trying to ini ate ac va on Disconnect the sensor and electronic box cables and wait for 30 seconds Reconnect the cables but allow for another 30 seconds before placing hands or a target within the sensor range You should hear a click of the solenoid once calibra on is complete Check if protec...

Page 6: ...6 XL B L 4 4 Cast Cover Plate w Gasket P6900 CP4 5 8 Cast Cover Plate w Gasket P6900 CP8 6 Mounting Kit P6900 43 7 Filter Kit P6900 120 8 Filter Screen P6900 MV 7 9 Mixing Valve w Filter P6900 XL MV 10 Mixing Tee w Filters and Back Checks P6900 XL MT Description Product No 11 Thermostatic Mixing Valve P6900 TMV 12 Single Stainless Supply Hose XL P6900 SSH 13 Stainless Supply Hoses XL P6900 SSH 2 1...

Reviews: