23
PROCEPTOR®
TECHNICAL MANUAL
6 Specification Sheets
GREASE WASTE INTERCEPTORS
PART 1 - GENERAL
1.1
RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01
Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section Includes:
1. Grease interceptors.
1.3 DEFINITIONS
A. FRP: Fiberglass-reinforced plastic.
1.4
ACTION SUBMITTALS
A. Product Data: Include materials of fabrication, dimensions, rated capacities, retention capacities, operating
characteristics, size and location of each pipe connection, furnished specialties, and accessories.
B. Shop Drawings: For each type and size of interceptor indicated .
1. Include materials of construction, dimensions, rated capacities, retention capacities, location and size of
each pipe connection, furnished specialties, and accessories.
1.5
INFORMATIONAL SUBMITTALS
A. Coordination Drawings: Interceptors, drawn to scale, on which the following items are shown and coordinated with
each other, based on input from Installers of the items involved:
1.
Interceptors.
2. Piping connections. Include size, location, and elevation of each.
3. Interface with underground structures and utility services.
1.6
PROJECT CONDITIONS
A. lnterruption of Existing Sewer Services: Do not interrupt services to facilities occupied by Owner or others unless
permitted under the following conditions and then only after arranging to provide temporary sewer services
according to requirements indicated:
1. Notify [Architect] [Construction Manager] [Owner] no fewer than [seven] <Insert number> days in advance
of proposed interruption of service.
2. Do not proceed with interruption of sewer services without [Architect's) [Construction Manager's)
(Owner's] written permission.