RDU, the four LED’s will blink and buzzer will sound on SEU & RDU., after that
the communication is ready, the content of display is same on SEU & RDU.
Mount the plug lock
9. Customizing Settings
When power has been connected, the SEU and RDU will begin to monitor the
CO2 concentration and the temperature. In order to the get the timely alarm safety
information and meet the personal requirements, It is advisable to set up the
customizing parameter when necessary.
Temperature ºC/ºF:
Using the DIAG function:
1. Press Mode until the “DIAG” icon flashes
2. Press Enter, the four LED’s will blink on the SEU and the buzzer will
sound
3. The four LED’s will blink and buzzer will sound simultaneously on
the RDU
Setting the First Alarm parameter:
1. Press Mode until the “AL1” icon flashes
2.Press Enter, the “AL1” icon shows on LCD
3. Press Mode to go through “
0.5%,1%,1.5%,2%
” alarm level
4. Press Enter again to save the setting after selection
Setting the Second Alarm parameter:
1. Press Mode until the “ AL2” icon flashes
2. Press Enter, the “AL2” icon shows on LCD
3. Press Mode to go through “
1.5%,2%,2.5%,3%,3.5%,4%
” alarm level
4. Press Enter again to save the setting after selection
Notes: The second alarm level should be higher than the first alarm level
when setting with the alarm level parameter.
Using the CALI function:
1. Press Mode until the “CALI” icon flashes
2. Press Enter, the “CALI” icon shows on the LCD
3. Press and hold Mode for at least 10 seconds. The “CALIBRATING”
icon will flash. The calibration will be done automatically. After 10
minutes the LCD will display “Pass” or “Fail”. If “Fail”, please try
again.
Notes: When do the calibration, it is suggested to take SEU outside, using
the ambient gas for calibration, waiting around 10 minutes until the CO2
reading of SEU doesn’t change, then use the 380-420 ppm as the
standard CO2 reading. Calibrating the unit according to “CALI” mode
instruction, user should not breathe toward to SEU during the calibration
process, as the CO2 from the user will affect the CO2 reading of SEU.
Using the ReFactSet function:
1. Press Mode until the “ReFactSet” icon flashes
2. Press Enter, and then press Mode to choose either “Yes” or “No”
3. Press Enter again to save the setting after selecting
Note: If the user sets the data or calibrates the sensor incorrectly, use the
ReFactSet (recover the factory Setting) to come back the default factory
setting.
10 .Specification
■
CO2 & Temperature specification:
CO2 Specification
Measurement Range
0 - 50,000 ppm (5%) display
Display Resolution
10 ppm
Accuracy
±100 ppm or ±5% of reading, whichever is
greater
Repeatability
±20 ppm @400 ppm
Annual Drift
<20 ppm/Year@400ppm
Temperature
Dependence
±0.2% of reading per °C or ±2 ppm per °C,
whichever is greater, referenced to 25°C
Pressure Dependence
0.13% of reading per mm Hg
Response Time
<60 seconds for 90% response to step
change
AL1
(First Alarm Level)
0.5 / 1 / 1.5 / 2 % , Default AL1= 1.5%
AL2
(Second Alarm Level)
1.5 / 2 / 2.5/ 3 / 3.5 / 4 % , Default AL2= 3%
Sound Alarm
80db@10cm
Warm-Up Time
<60 seconds at 22°C
Temperature Specification:
Temperature Range
0°C to 50°C (32°F to 122°F)
Display Resolution
0.1°C (0.1°F)
Display Options
°C/°F
Accuracy
±1°C(±2°F) when CO2 concentration is
below first alarm level
Response Time
20-30 minutes (case must equalize with
environment)
Operating Conditions:
Operating Temperature
0°C to 40°C ( 32°F to 104°F)
Humidity Range
0 ~ 95% RH non-condensing
Storage Conditions:
Storage Temperature
-20°C to 60 °C (-4°F to 140°F)
■
Power Supply & Relay Output:
Power Supply
AC adapter 110/220 VAC
Voltage
100 ~ 240 VAC
Frequency
50 / 60 Hz
AC
Input
Power
Requirement
1 W maximum @ 115 VAC 60 Hz
2 W maximum @ 230 VAC 50 Hz
Voltage 6VDC
AC/DC
Output Power 1.8
W
Peak Input Current
0.3 A from 6 VDC
Relay Output
30 VDC or 250 VAC, max 2A, SPST,
Normally Open
11. Weight & Dimension
Weight: SEU (Sensor Unit): 459 g
RDU (
Remote Display Unit
): 130 g
Dimension:
12. Fault Codes &Troubleshooting Guide
This section includes a list of Frequently Asked Questions for problems you may
encounter with the ZG10U CO2 Monitor.
No
LCD
Fault
Icon
Description
(of the fault)
SEU
Indication
RDU
Indication
Suggested Actions
1 Er3
The ambient
temperature has
exceeded the
temperature
range 0°C to
50°C ( 32°F to
122°F)
“Er3” flash
Fault LED
blink,
Buzzer
beep
“Er3” flash
Fault LED
blink,
Buzzer
beep
This error will disappear
when the temperature
returns to the range
between 0°C and 50°C
( 32°F to 122°F)
2 Er4
some wrong
measurement or
the sensor has
exceeded its
expected life
“Er4” flash
Fault LED
blink,
Buzzer
beep
“Er7” flash
Fault LED
blink,
Buzzer
beep
Please unplug the AC
adapter and reconnect it. If
the “Er4” always appears,
please contact with the
local dealer.
3
Er5
Er6
EEPROM
System Problem
“Er5” &
“Er6”
flash,
Fault LED
blink,
Buzzer
beep
“Er7” flash
Fault LED
blink,
Buzzer
beep
Please unplug the AC
adapter and reconnect it. If
the “Er5,Er6” always
appear, please contact with
the local dealer.
4
Er7
Internal Data
Transmission
Error
“Er7”
flash,
Fault LED
blink,
Buzzer
beep
“Er7”
flash,
Fault LED
Blink,
Buzzer
beep
①
Please unplug the AC
adapter and reconnected
it.
②
Check the RJ45 plug is
connected into the INPUT
port of RDU,if the “Er7”
displays on the RDU only.
5
Er8
The accuracy of
CO2 sensor may
deviate from the
actual CO2
concentration.
“Er8” flash
Fault LED
blink,
Buzzer
beep
“Er8” flash
Fault LED
blink,
Buzzer
beep
①
Please unplug the AC
adapter and reconnect it
If the “Er8” still appears,
please contact with the
local dealer.
②
Please calibrate the unit,
after the calibration, If the
“Er8” still appears, please
contact with the local
dealer.
1. Press “Enter” to switch between ºC and ºF temperature