background image

 

 
LCT-1631A Manual V1.0 

16 

Modulator Configuration via Front Panel LCD

 

 

Once  the  encoder  is  powered  up  it  will  go through  its  initial  booting  process.  Once  the  unit  has  completed  its 
initial  “Booting”  up  process  the  LCD  will  display  IN-1...,  Bit  Rate  information,  CHANNEL-1....,  and  other 
information in the LCD Display Window. When visible the unit is ready for programming or operation. 

 

 

Main Menu

– 

To access the Main Menu first enter the password by pressing the OK button. Use the Scroll 

Up/Down buttons to enter the password. The password is - 0000.Once the password is entered press the OK 
button again and the LCD Screen will display the Main Menu. 

 

 

RF Setup Menu 

 

 

Channel 

–  Use  the  Scroll  Up/Down  button  to  change  the  output  channel.  Use  the  Scroll 

Up/Down  buttons  to  select  the  desired  Output  Channel.  Once  the  desired  output  channel  is 
selected press the OK button to set the channel.

 

   The  LCD  Display  will  show  both  the  channel  number  and  the  frequency  number  of  the  output 

channel example: 39(606.5000MHz)

 

 

ONID

 

– 

Use the Scroll Up/Down button to select ONID. Press the OK button to enter the ONID 

menu. Use the Scroll Up/Down button to select the desired ONID ranging from 1 to 65535 then 
press the OK button to set. Factory default is 08228.

 

 

NID

 

– 

Use the Scroll Up/Down button to select NID. Press the OK button to enter the NID menu. 

Use the Scroll Up/Down button to select the desired NID ranging from 1 to 65535 then press the 
OK button to set. Factory default is 12801.

 

 

TSID

 

– 

Use the Scroll Up/Down button to select TSID. Press the OK button to enter the TSID 

menu. Use the Scroll Up/Down button to select the desired TSID ranging from 1 to 65535 then 
press the OK button to set. Factory default is 00001. Note: If installing multiple units in the same 
system – ensure each device must have a unique TSID.

 

 

Network Name

 

– Use the Scroll Up/Down button to select Network Name. Press the OK button 

to enter the Network Name menu. Use the Scroll Up/Down button to select the first character for 
the desired Network Name then press the OK button to set. Repeat the process for each character 
in the desired Network Name. A Network Name can consist up to 16 characters.

 

 

RF

 

– Use the Scroll Up/Down button to select RF. Press the OK button to enter the RF menu. Use 

the Scroll Up/Down button to select the desired RF, Normal or Inverted, then press OK button to 
set. Factory default is Normal.

 

 

Constellation

 

– The Constellation is default 64 QAM.

 

 

FEC

 

– The FEC is default 7/8.

 

 

GI

 

– The GI, Guard Interval, is default 1/32.

 

 

OFDM Mode

 

– Use the Scroll Up/Down button to select the OFDM menu. Press the OK button 

to enter the OFDM menu. Use the Scroll Up/Down to select the OFDM 2k or 8k. Press OK to set. 

Factory default is 8k. 

 

CELL ID

 

– The CELL ID is default 00000.

 

 

EXIT 

– Select EXIT to escape the RF Setup Menu.

 

 

Summary of Contents for LCT-1631A

Page 1: ...igital Modulator User Guide and Installation Manual ZyCast Technology Inc No 33 Lane 181 Chung Hwa Road Section 4 Hsin Chu Taiwan 30060 Tel 886 3 5400 949 Fax 886 3 5400 413 Australia NZ contact 61448100429 www zycast com tw ...

Page 2: ...8 1 9 7 Encoder Programming and Setup via GUI Interface 8 Step 1 Enter Device s IP address in web browser 8 Step 2 Enter User Name Password 8 Step 3 Encoder Setup 9 Step 4 RF Output Setup 11 Step 5 Network Configuration 12 Step 6 Administration 13 Front Panel Control 15 LCD Password 15 LCD Setup Menu Map 15 Modulator Configuration via Front Panel LCD 16 RF Setup Menu 16 Encoder Setup Menu 17 Netwo...

Page 3: ...e the manufacturer s warranty DO NOT connect the power cord to the device if the power cord is damaged DO NOT cut the power cord DO NOT plug the power cord into an AC outlet until all cables and connections to the device have been properly connected The device should be installed in an environment consistent with its operating temperature specifications Placement next to heating devices and ducts ...

Page 4: ... Modulator is perfect for multi video distribution solutions in the commercial and institutional market hotels motels sports bars restaurants hospitals casinos business and university campuses digital signage etc as well as home entertainment systems Features HDMI Component Composite Inputs RF Output Gain Control 20dB Manual Attenuation RJ 45 port for Web Management Video resolution Up to 1080i 10...

Page 5: ...DVB T HD 12 0 to 24 0Mbps SD 4 0 to 9 0Mbps Resolution Output Same as Input Accepting Resolution as Follows 1080p30 1080p25 1080i60 1080i50 720p60 720p50 576p 480p 576i 480i Audio Audio Codecs MPEG1 Layer II MPEG4 AAC AC 3 Encode Optional Output Standard DVB T Connector 1x F Female Output Level 95 dBµV Typical With 20dB Range Manually Adjustable Flatness Across Full Band 2 dB Typical MER 38 dB Typ...

Page 6: ...66 Mbps FEC 7 8 LCN Mode AU NZ OFDM Mode 2k 8k Guard Interval 1 32 General Local Monitoring LCD Web GUI Supported Firefox Chrome Password Protected GUI User Settable Power Supply 12VDC 1 5A Consumption 5W Operation Temperature 0 C to 55 C Storage Temperature 20 C to 70 C Dimension Housing 236 L x 145 W x 34 H mm Weight TBD Language English Specifications subject to change without notification Dolb...

Page 7: ...e video inputs The modulator is intelligently designed to detect the video input from the video source HDMI Connection Connect the HDMI cable from the video source into the HDMI input If using a Component Video Cable connect the Y Green Pb Blue and Pr Red video source cable to the unit s Component input port If using a Composite Video source use RCA connectors to connect the video source e g CATV ...

Page 8: ...Device s IP address in web browser Overview page shown the encoder s status and information as above Step 2 Enter Username Password Select Encoder Setup After selecting the Encoder Setup Tab the user will be prompted to enter the username and password for device GUI Login Password Default Username admin Default Password Admin123 Note To change the Password for the GUI go to the Administration Tab ...

Page 9: ...omponent or Composite Factory default Auto Detect HD Bitrate HD Bitrate range 12 0 24 0 Mbps Factory default 24 0 Mbps SD Bitrate SD Bitrate range 4 0 9 0 Mbps Factory default 4 0 Mbps Program Number Program Number range 1 to 65534 Factory default is 1 HDCP Test Mode Select to Enable Disable NOTE It is the installers property owner integrator s responsibility to contract with the service provider ...

Page 10: ...anges made will be show in the applet window see below example Select Submit Note To reset all changes made or saved go to the Administration Page and select Reset to Default Leaving the encoder page without saving changes will cause the previous settings to be used If the unit is outputting video to the system there will be a brief delay in the video while the parameters are saved ...

Page 11: ...fault ZyCast RF Output RF output option Normal or Inverted Factory default is Normal Channel Frequency Factory default is 39 606 5000MHz Constellation The Constellation is default 64 QAM FEC The FEC is default 7 8 Guard Interval The Guard Interval is default 1 32 OFDM Mode OFDM Mode option 2k or 8k Factory default is 8k CELL ID The CELL ID is default 0 Save and Confirm all changes settings on RF O...

Page 12: ... IP address GUI address of the device Subnet Mask Gateway Enable Disable DHCP and set Host Name Factory Default GUI IP is 192 168 1 9 Save and Confirm Once all parameters are set remember to Save and Confirm all changes Note It is highly recommended that the GUI Remote Setup IP address is recorded locally for access to the GUI in the field ...

Page 13: ...e highly recommend you save your configuration files Simply Click the Backup button and the config files will be saved to your computer Backup 1 Select Administration tab 2 Select backup from the menu 3 Locate and name file for future use Restore Upload saved file configurations 1 Select Administration tab 2 Select Browse menu 3 Locate the required file to be imported 4 Select UPLOAD to import the...

Page 14: ...e Upgrade Select BROWSE to select a new firmware image file and UPLOAD to update the Firmware if needed Change Password Use the Change Password section to change or modify the device s password as desired Save and Confirm new password ...

Page 15: ...sword Use the Scroll Up Down button to search and select individual numbers for the password Press the OK button for each number to enter the password Password Default password is 0000 LCD Setup Menu Map Main Menu RF Setup Encoder Setup Network Setup Change Password Reset to Default Exit Channel LCN Host Name ONID Channel Name IP Setup NID Provider Name Exit TSID Video Input Network Name HD Bitrat...

Page 16: ...ess the OK button to enter the NID menu Use the Scroll Up Down button to select the desired NID ranging from 1 to 65535 then press the OK button to set Factory default is 12801 TSID Use the Scroll Up Down button to select TSID Press the OK button to enter the TSID menu Use the Scroll Up Down button to select the desired TSID ranging from 1 to 65535 then press the OK button to set Factory default i...

Page 17: ...K button to set Factory default 24 0 Mbps SD Bitrate Use the Scroll Up Down button to select SD Bitrate Press the OK button to enter the SD Bitrate Input menu Use the Scroll Up Down button to select the desire SD Bitrate ranging from 1 0 9 0 Mbps Press the OK button to set Factory default 4 0 Mbps Program Number Use the Scroll Up Down button to select Program Number Press the OK button to enter th...

Page 18: ... then press the OK button to set Repeat the process until the IP Address is completed Press the OK button to set Subnet Mask Use the Scroll Up Down button to enter the Subnet Mask Use the Scroll Up Down menu to select the first number of the desired Subnet Mask then press the OK button to set Repeat the process until the Subnet Mask is completed Press the OK button to set Default Gateway Press the...

Page 19: ...LCT 1631A Manual V1 0 19 Distributed by ...