ZYPRESSEN UPS User Manual

SAVE THESE INSTRUCTIONS

• This UPS utilizes voltage that may be hazardous. Do not attempt to disassemble the unit.The unit con-

tains no user replaceable parts.  Only factory service personnel may perform repairs.

• This pluggable type A equipment with battery already installed by the supplier is operator installable and 

may be operated by laymen.

• The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily 

accessible.

• During the installation of this equipment it should be assured that the sum of the leakage currents of the 

UPS and the connected loads does not exceed 3.5mA.

• Connection to any other type of receptacle other than a two-pole, three-wire grounded receptacle may 

result in shock hazard as well as violate local electrical codes.

• In the event of an emergency, press the “OFF” button and disconnect the power cord from the AC power 

supply to properly disable the UPS.

• Do not allow any liquids or any foreign object to enter the UPS.  Do not place beverages or any other 

liquid-containing vessels on or near the unit.

• This unit intended for installation in a controlled environment (temperature controlled, indoor area free 

of conductive contaminants). Avoid installing the UPS in locations where there is standing or running 

water, or excessive humidity.

• Do not plug the UPS input into its own output.
• Do not attach a power strip or surge suppressor to the UPS.
• Do not attach non-computer-related items, such as medical equipment, life-support equipment, micro-

wave ovens, or vacuum cleaners to UPS.

• Do not dispose of batteries in a fire as they may explode.

• A battery can present a risk of electrical shock and high short circuit current.  The following precautions 

should be observed when working on batteries: 

1) Remove watches, rings, or other metal objects from the hands.

 

2) Use tools with insulated handles. 

3) Wear rubber gloves and boots. 

4) Do not lay tools or metal parts on top of batteries. 

5) Disconnect charging source prior to connecting or dis-connecting batteries terminal.

• Internal battery voltage is 12VDC.Sealed, lead-acid, 6-cell battery.
• Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and 

the required precautions.  Keep unauthorized personnel away from batteries.

• When replacing batteries, replace with the same number and type of sealed lead-acid battery.
• Do not open or mutilate the battery or batteries.  Release electrolyte is harmful to the skin and eyes.  

It may be toxic.

• Attention, hazardous through electric shock. Also with dis- connection of this unit from the mains, 

hazardous voltage still may be accessible through supply from battery. The battery supply should be 

therefore disconnected in the plus and minus pole at the connectors of the battery when maintenance or 

service work inside the UPS is necessary.

• To reduce the risk of overheating the UPS, do not cover the UPS’ cooling vents and avoid exposing 

the unit to direct sunlight or installing the unit near heat emitting appliances such as space heater or 

furnaces.

• Unplug the UPS prior to cleaning and do not use liquid or spray detergent.

This manual contains important instructions that should be followed during installation and 

maintenance of the UPS and batteries.

Summary of Contents for Z3 1000VA USB

Page 1: ...1 UPS User Manual Z3 650VA Z3 850VA Z3 1000VA USB Z5 1500VA...

Page 2: ......

Page 3: ...er Manual Introduction Operation and Functions Rear Panel Alarm Placement and Storage Specifications Troubleshooting SAVE THESE INSTRUCTIONS 5 6 7 8 9 9 10 12 13 25 26 27 28 29 29 30 32 33 15 16 17 18...

Page 4: ......

Page 5: ...he Manual provides you with step by step guidance to install use UPS It contains important safety instructions for operation correct installation of the UPS In case you have any problem with the UPS p...

Page 6: ...fe and fully charge the battery 4 Overload short circuit protection both in line and battery mode ZYPRESSEN UPS products are designed keeping in mind any possible severe conditions It has below unique...

Page 7: ...switch lightly Then the LED will light up To turn off the UPS unit press the power switch again Then the LED will go off When the UPS is off and there is no power utility it s still possible to cold s...

Page 8: ...communication port only for Z3 1000VA UPS To monitor the UPS status such as unattended UPS shutdown and start up by using download software please connect the UPS and PC with USB cable included Indica...

Page 9: ...a UPS fault occurs the UPS will continuously beep Install the UPS in a protected area that is free of excessive dust and has adequate air flow Place the UPS away from other units at least 20 cm to av...

Page 10: ...Inbuilt Power cord 1 2m with Schuko plug 195V to 260V Follows I P 230V 10 50 Hz Quasi sinewave 0 6 Universal x 3 Nos YES 5 min Fuse UPS shutdown UPS shutdown YES Fuse 12 VDC 1A YES SMF 12V 7 5AH YES...

Page 11: ...verload battery low 5 5 kg 279x101x142 mm USB port Monitoring software included 230V 50Hz 170 V to 280V Yes Inbuilt Power cord 1 2m with Schuko plug 200V to 255V Follows I P 230V 10 50 Hz Quasi sinewa...

Page 12: ...n to turn on the UPS Charge the battery at least 6 hours Replace the battery Re plug the input power cord Remove some unnecessary loads Before reconnecting equipment please verify that the load matche...

Page 13: ...wave ovens or vacuum cleaners to UPS Do not dispose of batteries in a fire as they may explode A battery can present a risk of electrical shock and high short circuit current The following precautions...

Page 14: ......

Page 15: ...15 Z3 650VA Z3 850VA Z3 1000VA USB Z5 1500VA...

Page 16: ...16 ZYPRESSEN 1 140 300 2 3 4 3 1 2 3 4 ZYPRESSEN 6 1 2 3...

Page 17: ...17 ZYPRESSEN Z3 1000VA USB ViewPower CD ViewPower 1 2 3 4...

Page 18: ...18 ZYPRESSEN Z3 650VA Z3 850VA Z3 1000VA Z5 1500VA USB Z3 1000VA USB...

Page 19: ...19 ZYPRESSEN 10 0 5 20 0 C 40 C 20 C 50 C...

Page 20: ...650VA 650 390 Z3 850VA 850 500 230 50 140 300 1 2 CEE 7 4 195 260 230 10 50 0 6 x 3 5 12 1A SMF 12V 7 5AH 1 4 2 279x101x142 230 50 140 300 1 2 CEE 7 4 195 260 230 10 50 0 6 x 3 5 12 1A SMF 12V 9AH 3...

Page 21: ...00 600 Z5 1500VA 1500 900 230 50 140 300 1 2 CEE 7 4 195 260 230 10 50 0 6 x 3 5 12 1A SMF Yuasa 12V 9AH 3 5 5 279x101x142 USB 230 50 170 280 1 2 CEE 7 4 200 255 230 10 50 0 6 x 4 24 1A SMF 2 x 12V 9A...

Page 22: ...22 ZYPRESSEN 6 6...

Page 23: ...23 ZYPRESSEN A 3 5 1 2 3 4 5 12 6...

Page 24: ...24...

Page 25: ...25 Z3 650VA Z3 850VA Z3 1000VA USB Z5 1500VA...

Page 26: ...26 ZYPRESSEN 1 140 300 2 3 4 3 1 2 3 4 ZYPRESSEN 6 1 2 3...

Page 27: ...27 ZYPRESSEN Z3 1000VA USB ViewPower CD ViewPower 1 2 3 4...

Page 28: ...28 ZYPRESSEN Z3 650VA Z3 850VA Z3 1000VA Z5 1500VA USB Z3 1000VA USB...

Page 29: ...29 ZYPRESSEN 10 10 0 5 20 0 C 40 C 20 C 50 C...

Page 30: ...650VA 650 390 230 50 140 300 1 2 CEE 7 4 195 260 230 10 50 0 6 x 3 5 12 1A SMF 12V 7 5AH 1 4 2 279x101x142 Z3 850VA 850 500 230 50 140 300 1 2 CEE 7 4 195 260 230 10 50 0 6 x 3 5 12 1A SMF 12V 9AH 3...

Page 31: ...900 Z3 1000VA USB 1000 600 230 50 140 300 1 2 CEE 7 4 195 260 230 10 50 0 6 x 3 5 12 1A SMF Yuasa 12V 9AH 3 5 5 279x101x142 USB 230 50 170 280 1 2 CEE 7 4 200 255 230 10 50 0 6 x 4 24 1A SMF 2 x 12V...

Page 32: ...32 ZYPRESSEN 6 6...

Page 33: ...33 ZYPRESSEN 3 5 1 2 3 4 5 12 6...

Page 34: ......

Page 35: ......

Page 36: ...www zypressenpower com...

Reviews: