13
ZYPRESSEN UPS User Manual
SAVE THESE INSTRUCTIONS
• This UPS utilizes voltage that may be hazardous. Do not attempt to disassemble the unit.The unit con-
tains no user replaceable parts. Only factory service personnel may perform repairs.
• This pluggable type A equipment with battery already installed by the supplier is operator installable and
may be operated by laymen.
• The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily
accessible.
• During the installation of this equipment it should be assured that the sum of the leakage currents of the
UPS and the connected loads does not exceed 3.5mA.
• Connection to any other type of receptacle other than a two-pole, three-wire grounded receptacle may
result in shock hazard as well as violate local electrical codes.
• In the event of an emergency, press the “OFF” button and disconnect the power cord from the AC power
supply to properly disable the UPS.
• Do not allow any liquids or any foreign object to enter the UPS. Do not place beverages or any other
liquid-containing vessels on or near the unit.
• This unit intended for installation in a controlled environment (temperature controlled, indoor area free
of conductive contaminants). Avoid installing the UPS in locations where there is standing or running
water, or excessive humidity.
• Do not plug the UPS input into its own output.
• Do not attach a power strip or surge suppressor to the UPS.
• Do not attach non-computer-related items, such as medical equipment, life-support equipment, micro-
wave ovens, or vacuum cleaners to UPS.
• Do not dispose of batteries in a fire as they may explode.
• A battery can present a risk of electrical shock and high short circuit current. The following precautions
should be observed when working on batteries:
1) Remove watches, rings, or other metal objects from the hands.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries.
5) Disconnect charging source prior to connecting or dis-connecting batteries terminal.
• Internal battery voltage is 12VDC.Sealed, lead-acid, 6-cell battery.
• Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and
the required precautions. Keep unauthorized personnel away from batteries.
• When replacing batteries, replace with the same number and type of sealed lead-acid battery.
• Do not open or mutilate the battery or batteries. Release electrolyte is harmful to the skin and eyes.
It may be toxic.
• Attention, hazardous through electric shock. Also with dis- connection of this unit from the mains,
hazardous voltage still may be accessible through supply from battery. The battery supply should be
therefore disconnected in the plus and minus pole at the connectors of the battery when maintenance or
service work inside the UPS is necessary.
• To reduce the risk of overheating the UPS, do not cover the UPS’ cooling vents and avoid exposing
the unit to direct sunlight or installing the unit near heat emitting appliances such as space heater or
furnaces.
• Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
This manual contains important instructions that should be followed during installation and
maintenance of the UPS and batteries.
Summary of Contents for Z3 1000VA USB
Page 1: ...1 UPS User Manual Z3 650VA Z3 850VA Z3 1000VA USB Z5 1500VA...
Page 2: ......
Page 4: ......
Page 14: ......
Page 15: ...15 Z3 650VA Z3 850VA Z3 1000VA USB Z5 1500VA...
Page 16: ...16 ZYPRESSEN 1 140 300 2 3 4 3 1 2 3 4 ZYPRESSEN 6 1 2 3...
Page 17: ...17 ZYPRESSEN Z3 1000VA USB ViewPower CD ViewPower 1 2 3 4...
Page 18: ...18 ZYPRESSEN Z3 650VA Z3 850VA Z3 1000VA Z5 1500VA USB Z3 1000VA USB...
Page 19: ...19 ZYPRESSEN 10 0 5 20 0 C 40 C 20 C 50 C...
Page 22: ...22 ZYPRESSEN 6 6...
Page 23: ...23 ZYPRESSEN A 3 5 1 2 3 4 5 12 6...
Page 24: ...24...
Page 25: ...25 Z3 650VA Z3 850VA Z3 1000VA USB Z5 1500VA...
Page 26: ...26 ZYPRESSEN 1 140 300 2 3 4 3 1 2 3 4 ZYPRESSEN 6 1 2 3...
Page 27: ...27 ZYPRESSEN Z3 1000VA USB ViewPower CD ViewPower 1 2 3 4...
Page 28: ...28 ZYPRESSEN Z3 650VA Z3 850VA Z3 1000VA Z5 1500VA USB Z3 1000VA USB...
Page 29: ...29 ZYPRESSEN 10 10 0 5 20 0 C 40 C 20 C 50 C...
Page 32: ...32 ZYPRESSEN 6 6...
Page 33: ...33 ZYPRESSEN 3 5 1 2 3 4 5 12 6...
Page 34: ......
Page 35: ......
Page 36: ...www zypressenpower com...