Chapter 2 Hardware Installation and Connection
GS1915 Series User’s Guide
28
3
Attach the rubber feet to each corner on the bottom of the Switch. These rubber feet help protect the
Switch from shock or vibration and ensure space between devices when stacking.
Figure 7
Attaching Rubber Feet
4
Set the Switch on a smooth, level surface strong enough to support the weight of the Switch and the
connected cables. Make sure there is a power outlet nearby.
Cautions:
• Avoid stacking fanless Switches to prevent overheating.
• Ensure enough clearance around the Switch to allow air circulation for cooling.
• Do NOT remove the rubber feet as it provides space for air circulation.
2.4 Wall Mounting
The Switch can be mounted on a wall. You may need screw anchors if mounting on a concrete or brick
wall.
2.4.1 Installation Requirements
• Use screws with 6 mm – 8 mm (0.24" – 0.31") wide heads.
• The distance between the screws: 176 mm.
The following figure shows the screw specifications used for wall mounting.
• D = 7.00 mm
• H = 2.00 mm
• L= 15.50 mm
• d = 3.50 mm