background image

 

 
 

 
 

 
212 

5.4.38  IPMC – IGMP Snooping Status 

 

This page provides 

IGMP

 Snooping status.

 

 

 

 

Object 

Description 

VLAN ID 

The 

VLAN

 ID of the entry. 

Querier Version 

Working Querier Version currently. 

Host Version 

Working Host Version currently. 

Querier Status 

Shows the Querier status is "ACTIVE" or "IDLE".   
"DISABLE" denotes the specific interface is administratively disabled. 

Querier Transmitted 

The number of Transmitted Queries. 

Queries Received 

The number of Received Queries. 

V1 Report Received 

The number of Received V1 Reports. 

V2 Report Received 

The number of Received V2 Reports. 

V3 Report Received 

The number of Received V3 Reports. 

V2 Leaves Received 

The number of Received V2 Leaves. 

Router Port 

Display which ports act as router ports. A router port is a port on the Ethernet switch 
that leads towards the Layer 3 multicast device or 

IGMP querier

.   

Static denotes the specific port is configured to be a router port.   
Dynamic denotes the specific port is learnt to be a router port.   
Both denote the specific port is configured or learnt to be a router port. 

Port 

Switch port number. 

Status 

Indicate whether specific port is a router port or not. 

 

Buttons 

 

Check this box to refresh the page automatically. Automatic refresh occurs every 3 
seconds. 

 

Click to refresh the page immediately.

 

 

Clears all Statistics counters. 

 
 
 
 

 

Summary of Contents for RGS Series

Page 1: ...s Rugged Switch Series Version 1 Edition 3 07 2019 Hardware and Web User s Guide Default Login Details LAN IP Address http 192 168 1 1 User Name admin Password 1234 Copyright 2019 Zyxel Communications Corporation ...

Page 2: ...system Every effort has been made to ensure that the information in this manual is accurate Related Documentation CLI Reference Guide The CLI Reference Guide explains how to use the Command Line Interface CLI to configure the Switch Note It is recommended you use the Web Configurator to configure the Switch Web Configurator Online Help Click the help icon in any screen for help in configuring that...

Page 3: ...ion Optional 23 3 10 CLI Initialization and Configuration Optional 25 3 11 Monitoring the Ethernet Interface 26 3 12 Upgrade Software 26 3 13 Reset to Default and Save Configure 27 3 14 DIP Switch Setting for RGS100 5P 30 3 15 LED Status Indications 30 4 Introduction 32 4 1 System Description 32 4 2 Using the Web Interface 32 4 2 1 Web Browser Support 32 4 2 2 Navigation 33 4 2 3 Title Bar Icons 3...

Page 4: ... 79 5 3 31 ACL Rate Limiters 80 5 3 32 Access Control List 82 5 3 33 IP Source Guard Configuration 89 5 3 34 IP Source Guard Static Table 91 5 3 35 ARP Inspection Port Configuration 92 5 3 36 VLAN Configuration 94 5 3 37 Static Table 95 5 3 38 Dynamic Table 96 5 3 39 AAA RADIUS 97 5 3 40 TACACS 99 5 3 41 Aggregation Static Aggregation 101 5 3 42 LACP Aggregation 103 5 3 43 Loop Protection 105 5 3 ...

Page 5: ...irror 166 5 3 79 GVRP Global Config 168 5 3 80 Port Config 169 5 3 81 RingV2 170 5 3 82 DDMI 172 5 4 Monitor 173 5 4 1 System System Information 173 5 4 2 CPU Load 174 5 4 3 IP Status 175 5 4 4 System Log 176 5 4 5 System Detailed Log 177 5 4 6 System Alarm 177 5 4 7 EEE Port Power Saving 178 5 4 8 Ports Port State 179 5 4 9 Traffic Overview 180 5 4 10 QoS Statistics 181 5 4 11 QCL Status 182 5 4 ...

Page 6: ...ng Status 215 5 4 42 Groups Information 216 5 4 43 IPv6 SFM Information 217 5 4 44 LLDP Neighbors 218 5 4 45 LLDP MED Neighbors 219 5 4 46 PoE Status 223 5 4 47 EEE 225 5 4 48 Port Statistics 227 5 4 49 MAC Table 228 5 4 50 VLANs VLANs Membership 230 5 4 51 VLANs Ports 231 5 4 52 RingV2 233 5 4 53 DDMI Overview 233 5 4 54 DDMI Detailed 234 5 5 Diagnostics 235 5 5 1 Ping 235 5 5 2 Ping6 237 5 5 3 V...

Page 7: ...7 Preface Scope Audience Safety Instructions Documentation Conventions ...

Page 8: ...rimary hazards of exposure to laser radiation from an optical fiber communication system are Damage to the eye by accidental exposure to a beam emitted by a laser source Damage to the eye from viewing a connector attached to a broken fiber or an energized fiber 1 4 Documentation Conventions The following conventions are used in this manual to emphasize information that will be of interest to the r...

Page 9: ...9 Overview Overview Faceplate Panel Introduction ...

Page 10: ...net solutions deliver high quality wide operation temperature range extended power input range and advanced VLAN QoS features It s ideal for harsh environments and mission critical applications 2 1 Faceplate 5 Port Series 2 Overview ...

Page 11: ...em Status LED P1 P2 and Alarm Gigabit Ethernet Copper Ports RJ45 Gigabit Ethernet SFP ports SFP Slots POE LED POE port status RR RS LED Device info status Models L2 Managed Switch RGS200 12P Total Gigabit Ethernet Ports 12 10 100 1000 BaseT X 8 100 1000 Base SFP 4 ...

Page 12: ...12 2 3 Top Panel Introduction Top Panel Power Input Dual 6P Terminal Block Console RS232 RJ45 Reset Push Button ...

Page 13: ...13 Quick Installation Equipment Mounting Cable Connecting Equipment Configuration ...

Page 14: ...Rail bracket on with the bracket and screws in the accessory kit 2 Hook the unit over the DIN rail 3 Push the bottom of the unit towards the DIN Rail until it snaps into place Figure 1 RGS100 5P DIN Rail Mounting Figure 2 RGS200 12P DIN Rail Mounting 3 Quick Installation ...

Page 15: ...ll 2 3 1 Installation Requirements Distance above the floor At least 1 8 m 5 9 feet Distance between holes 151 mm 5 945 inches for RGS100 5P 172 mm 6 772 inches for RGS200 12P Two M4 screws and a 2 Philips screwdriver Two screw anchors optional Mounting step 1 Screw on the wall mounting plate on with the plate and screws in the accessory kit ...

Page 16: ...16 Figure 3 RGS100 5P Series Wall Mounting Figure 4 RGS200 12P Series Wall Mounting 3 3 Ground Connections RGS Series must be properly grounded for optimum system performance ...

Page 17: ...ng s protective earthing terminal is a valid terminal 1 Remove the M4 ground screw from the Switch s panel 2 Secure a green yellow ground cable 16 AWG or smaller to the Switch s panel using the M4 ground screw 3 Attach the other end of the cable to the ground either to the same ground electrode as the rack you installed the device on or to the main grounding electrode of the building Follow your c...

Page 18: ...18 Figure 6 RGS200 12P Series Ground Connections ...

Page 19: ...e switch to an Ethernet device use UTP Unshielded Twisted Pair or STP Shielded Twisted Pair Ethernet cables The pin assignment of RJ 45 connector is shown in the following figure and table The pin assignment of RJ 45 connector is shown in the following figure and table RGS Series RGS200 12P series Pin Assignment PoE Assignment 1 2 T Rx T Rx Positive VPort 3 6 T Rx T Rx Negative VPort 4 5 T Rx T Rx...

Page 20: ...ally have an LC style connector They are available with multimode single mode long haul for connections up to 80 km or special application transceivers For each fiber port there is a transmit TX and receive RX signal Please make sure that the transmit TX port of the switch connects to the receiver RX port of the other device and the receive RX port of the switch connects to the transmit TX port of...

Page 21: ...r is a 6 pin terminal block there is alarm contact on the middle terminal block Refer to Table 1 for the normal operational LED status Figure 7 RGS100 5P Series Power Connections Figure 8 RGS200 12P Series Ground Connections Note 1 The DC power should be connected to a well fused power supply Power Connector 6P Terminal Block Input DC 12 58V PWR1 Power Input 1 PWR2 Power Input 2 ALM Alarm relay ou...

Page 22: ... 8 data bits 1 stop bit None parity None flow control Figure 10 RGS200 12P Series Ground Connections To connect the host PC to the console port a RJ45 male connector to RS232 DB9 female connector cable is required The RJ45 connector of the cable is connected to the CID port of RGS200 12P the DB9 connector of the cable is connected to the PC COM port The pin assignment of the console cable is shown...

Page 23: ... need to push the Reset button 3 9 Web Interface Initialization Optional Web Browser Support IE 7 or newer version with the following default settings is recommended Language script Latin based Web page font Times New Roman Plain text font Courier New Encoding Unicode UTF 8 Text size Medium Firefox with the following default settings is recommended Web page font Times New Roman Encoding Unicode UT...

Page 24: ...d Web page font Times New Roman Encoding Unicode UTF 8 Text size Medium Connect and Login to RGS200 12P 1 Connecting to RGS200 12P Ethernet port RJ45 Ethernet port 2 Factory default IP 192 168 1 1 3 Login with default account and password Username admin Password 1234 ...

Page 25: ...ort RJ45 Ethernet port 2 Key in the command under Telnet telnet 192 168 1 1 3 Login with default account and password Username admin Password 1234 4 Change the IP with commands listed below CLI Command enable configure terminal interface vlan 1 ip address xxx xxx xxx xxx xxx xxx xxx xxx exit ...

Page 26: ...status By SFP Refer to Figure 11 LED Indicators for monitoring 4 Gigabit Ethernet with SFP connector Also refer to Table 1 for the normal operational LED status 3 12 Upgrade Software 1 In Web UI go to Maintenance Software Upload page 2 Select software file and click Upload button 3 After starting to upload software to device please don t cold warm start device and wait it auto reboot then upgrade ...

Page 27: ...e this command reload defaults keep ip 2 Check interface VLAN and IP address confirm only management IP setting kept 3 Execute this command copy running config startup config If manager want to reset the all configuration to default completely 1 Please execute this command reload defaults 2 Check interface VLAN and IP address confirm they all change to default setting 3 Execute this command copy r...

Page 28: ...ts pagination to Click Yes button 2 Go to Maintenance Configuration Save startup config pagination then click Save Configuration button then reset successfully If manager want to reset the all configuration to default completely 1 Go to Maintenance Configuration Activate pagination to select default config then click Activate Configuration button ...

Page 29: ...29 2 Change WEB s IP be 192 0 2 1 default IP to login DUT s Web UI 3 Go to Maintenance Configuration Save startup config pagination then click Save Configuration button then reset successfully ...

Page 30: ...fails alarm or power failure alarm occurs Off No Ethernet link fails and no power failure alarm Copper port Link Act On Green Ethernet link up but no traffic is detected Flashing Green Ethernet link up and there is traffic detected Off Ethernet link down Copper port Speed On Yellow A 1000Mbps connection is detected Off No link a 10Mbps or 100 Mbps connection is detected SFP port Link A ct On Green...

Page 31: ...31 PWR LED Indicator Figure 11 LED Indicators ALM LED Indicator Copper Speed LED Copper Link Act LED SFP Speed LED Indicator SFP Link LED Indicator ...

Page 32: ...g protection and QoS customers can ensure their network is qualified to deliver any real time and high quality applications 4 2 Using the Web Interface The object of this document RGS Web Configuration Tool Guide is to address the web feature design layout and descript how to use the web interface 4 2 1 Web Browser Support IE 7 or newer version with the following default settings is recommended La...

Page 33: ... Maintenance 4 2 3 Title Bar Icons Help Button For more information about any screen click on the Help button on the screen Help information is displayed in the same window Apply Button Click Apply to apply the configuration changes to the device 4 2 4 Ending a Session To end a session close your web browser This prevents an unauthorized user from accessing the system using your user name and pass...

Page 34: ...Help Each screen has a Help button that invokes a page of information relevant to the particular screen The Help is displayed in a new window Each web page of Configuration Status System functions has a corresponding help page ...

Page 35: ... It offers user quickly to get the page for expected data or configuration Operation 1 Fill Username and Password 2 Click Sign in Field Description Username Login user name The maximum length is 32 Default admin Password Login user password The maximum length is 32 Default none ...

Page 36: ...36 5 2 1 Configuration Menu ...

Page 37: ...37 5 2 2 Monitor Menu ...

Page 38: ...38 5 2 3 Diagnostics Menu 5 2 4 Maintenance Menu ...

Page 39: ...s managed node By convention this is the node s fully qualified domain name A domain name is a text string drawn from the alphabet A Za z digits 0 9 minus sign No space characters are permitted as part of a name The first character must be an alpha character And the first or last character must not be a minus sign The allowed string length is 0 to 255 System Location The physical location of this ...

Page 40: ...erver offered from a DHCP lease to a DHCP enabled interface will be used No DNS server No DNS server will be used Configured Explicitly provide the IP address of the DNS Server in dotted decimal notation From this DHCP interface Specify from which DHCP enabled interface a provided DNS server should be preferred DNS Proxy When DNS proxy is enabled system will relay DNS requests to the currently con...

Page 41: ...mal digits with a colon separating each field For example fe80 215 c5ff fe03 4dc7 The symbol is a special syntax that can be used as a shorthand way of representing multiple 16 bit groups of contiguous zeros but it can appear only once It can also represent a legally valid IPv4 address For example 192 1 2 34 The field may be left blank if IPv6 operation on the interface is not desired IPv6 Mask Th...

Page 42: ...128 bit records represented as eight fields of up to four hexadecimal digits with a colon separating each field For example fe80 215 c5ff fe03 4dc7 The symbol is a special syntax that can be used as a shorthand way of representing multiple 16 bit groups of contiguous zeros but it can appear only once It can also represent a legally valid IPv4 address For example 192 1 2 34 Buttons Click to apply c...

Page 43: ...me Zone Lists various Time Zones worldwide Select appropriate Time Zone from the drop down and click Save to set Acronym User can set the acronym of the time zone This is a User configurable acronym to identify the time zone Range Up to 16 characters ...

Page 44: ...ours Select the ending hour Minutes Select the ending minute Offset settings Offset Enter the number of minutes to add during Daylight Saving Time Range 1 to 1440 Non Recurring Configurations Start time settings Month Select the starting month Date Select the starting date Year Select the starting year Hours Select the starting hour Minutes Select the starting minute End time settings Month Select...

Page 45: ...l always send out even if the syslog server does not exist Possible modes are Enabled Enable server mode operation Disabled Disable server mode operation Server Address Indicates the IPv4 host address of syslog server If the switch provide DNS feature it also can be a host name Syslog Level Indicates what kind of message will send to syslog server Possible modes are Info Send information warnings ...

Page 46: ...MP trap will be sent if any SNMP trap entry exists and enabled Disabled If alarm entry is Disabled then alarm will not be captured shown in alarm history current when alarm occurs then it will not trigger the Alarm LED change Alarm Relay and SNMP trap either Note When any alarm exists the Alarm LED will be on lighted Alarm Output Relay will also be enabled Buttons Click to apply changes Click to u...

Page 47: ...ving or least traffic latency Port Configuration Port The switch port number of the logical port ActiPHY Link down power savings enabled ActiPHY works by lowering the power for a port when there is no link The port is power up for short moment in order to determine if cable is inserted PerfectReach Cable length power savings enabled PerfectReach works by determining the cable length and lowering t...

Page 48: ...s by mapping the frames to a specific queue done with QOS and then mark the queue as an urgent queue When an urgent queue gets data to be transmitted the circuits will be powered up at once and the latency will be reduced to the wakeup time EEE Urgent Queues Queues set will activate transmission of frames as soon as data is available Otherwise the queue will postpone transmission until a burst of ...

Page 49: ...bps HDX Forces the cu port in 100Mbps half duplex mode 100Mbps FDX Forces the cu port in 100Mbps full duplex mode 1Gbps FDX Forces the port in 1Gbps full duplex Flow Control When Auto Speed is selected on a port this section indicates the flow control capability that is advertised to the link partner When a fixed speed setting is selected that is what is used The Current Rx column indicates whethe...

Page 50: ...ooping Configure DHCP Snooping on this page Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values Click to refresh the page Any changes made locally will be undone ...

Page 51: ...GIADDR field to determine the assigned subnet For such condition please make sure the switch configuration of VLAN interface IP address and PVID Port VLAN ID correctly Object Description Relay Mode Indicates the DHCP relay mode operation Possible modes are Enabled Enable DHCP relay mode operation When DHCP relay mode operation is enabled the agent forwards and transfers DHCP messages between the c...

Page 52: ...CP relay information mode operation Relay Information Policy Indicates the DHCP relay information option policy When DHCP relay information mode operation is enabled if the agent receives a DHCP message that already contains relay agent information it will enforce the policy The Replace policy is invalid when relay information mode is disabled Possible policies are Keep Keep the original relay inf...

Page 53: ...e fully control of the device But others value need to refer to each group privilege level User s privilege should be same or greater than the group privilege level to have the access of that group By default setting most group privilege level 5 has the read only access and privilege level 10 has the read write access And the system maintenance software upload factory defaults and etc need user pr...

Page 54: ...54 5 3 12 Privilege Level This page provides an overview of the privilege levels ...

Page 55: ...t Everything except VeriPHY Diagnostics ping and VeriPHY Maintenance CLI System Reboot System Restore Default System Password Configuration Save Configuration Load and Firmware Load Web Users Privilege Levels and everything in Maintenance Debug Only present in CLI Privilege Levels Every group has an authorization Privilege level for the following sub groups configuration read only configuration ex...

Page 56: ...rver s for authentication tacacs Use remote TACACS server s for authentication Methods that involve remote servers are timed out if the remote servers are offline In this case the next method is tried Each method is tried from left to right and continues until a method either approves or rejects a user If a remote server is used for primary authentication it is recommended to configure secondary a...

Page 57: ...t Description Mode Indicates the SSH mode operation Possible modes are Enabled Enable SSH mode operation Disabled Disable SSH mode operation Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...

Page 58: ...tion Disabled Disable HTTPS mode operation Automatic Redirect Indicates the HTTPS redirect mode operation It only significant if HTTPS mode Enabled is selected Automatically redirects web browser to an HTTPS connection when both HTTPS mode and Automatic Redirect are enabled Possible modes are Enabled Enable HTTPS redirect mode operation Disabled Disable HTTPS redirect mode operation Buttons Click ...

Page 59: ...ddress Indicates the start IP address for the access management entry End IP address Indicates the end IP address for the access management entry HTTP HTTPS Indicates that the host can access the switch from HTTP HTTPS interface if the host IP address matches the IP address range provided in the entry SNMP Indicates that the host can access the switch from SNMP interface if the host IP address mat...

Page 60: ...onfigure security name than a SNMPv1 or SNMPv2c community string In addition to community string a particular range of source addresses can be used to restrict source subnet Write Community Indicates the community writes access string to permit access to SNMP agent The allowed string length is 0 to 255 and the allowed content is the ASCII characters from 33 to 126 The field is applicable only when...

Page 61: ...61 Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...

Page 62: ...ndicates the SNMP trap destination address It allows a valid IP address in dotted decimal notation x y z w And it also allows a valid hostname A valid hostname is a string drawn from the alphabet A Za z digits 0 9 dot dash Spaces are not allowed the first character must be an alpha character and the first and last characters must not be a dot or a dash Indicates the SNMP trap destination IPv6 addr...

Page 63: ...ending SNMP trap packet The allowed string length is 0 to 255 and the allowed content is ASCII characters from 33 to 126 Trap Destination Address Indicates the SNMP trap destination address It allows a valid IP address in dotted decimal notation x y z w And it also allows a valid hostname A valid hostname is a string drawn from the alphabet A Za z digits 0 9 dot dash Spaces are not allowed the fir...

Page 64: ...meout The allowed range is 0 to 2147 Trap Inform Retry Times Indicates the SNMP trap informs retry times The allowed range is 0 to 255 Trap Probe Security Engine ID Indicates the SNMP trap probe security engine ID mode of operation Possible values are Enabled Enable SNMP trap probe security engine ID mode of operation Disabled Disable SNMP trap probe security engine ID mode of operation Trap Secur...

Page 65: ...and the allowed content is ASCII characters from 33 to 126 The community string will be treated as security name and map a SNMPv1 or SNMPv2c community string Source IP Indicates the SNMP access source address A particular range of source addresses can be used to restrict source subnet when combined with source mask Source Mask Indicates the SNMP access source address mask Buttons Click to add a ne...

Page 66: ...iv No authentication and no privacy Auth NoPriv Authentication and no privacy Auth Priv Authentication and privacy The value of security level cannot be modified if entry already exists That means it must first be ensured that the value is set correctly Authentication Protocol Indicates the authentication protocol that this entry should belong to Possible authentication protocols are None No authe...

Page 67: ...67 Buttons Click to add a new user entry Click to apply changes Click to undo any changes made locally and revert to previously saved values ...

Page 68: ...eserved for SNMPv2c usm User based Security Model USM Security Name A string identifying the security name that this entry should belong to The allowed string length is 1 to 32 and the allowed content is ASCII characters from 33 to 126 Group Name A string identifying the group name that this entry should belong to The allowed string length is 1 to 32 and the allowed content is ASCII characters fro...

Page 69: ... types are included An optional flag to indicate that this view subtree should be included excluded An optional flag to indicate that this view subtree should be excluded In general if a view entry s view type is excluded there should be another view entry existing with view type as included and its OID subtree should overstep the excluded view entry OID Subtree The OID defining the root of the su...

Page 70: ...curity Model USM Security Level Indicates the security model that this entry should belong to Possible security models are NoAuth NoPriv No authentication and no privacy Auth NoPriv Authentication and no privacy Auth Priv Authentication and privacy Read View Name The name of the MIB view defining the MIB objects for which this request may request the current values The allowed string length is 1 t...

Page 71: ... ID Indicates the index of the entry The range is from 1 to 65535 Data Source Indicates the port ID which wants to be monitored If in stacking switch the value must add 1000 switch ID 1 for example if the port is switch 3 port 5 the value is 2005 Buttons Click to add a new community entry Click to apply changes Click to undo any changes made locally and revert to previously saved values ...

Page 72: ...tch ID 1 for example if the port is switch 3 port 5 the value is 2005 Interval Indicates the interval in seconds for sampling the history statistics data The range is from 1 to 3600 default value is 1800 seconds Buckets Indicates the maximum data entries associated this History control entry stored in RMON The range is from 1 to 3600 default value is 50 Buckets Granted The number of data shall be ...

Page 73: ...haracters OutUcastPkts The number of uni cast packets that request to transmit OutNUcastPkts The number of broad cast and multi cast packets that request to transmit OutDiscards The number of outbound packets that are discarded event the packets are normal OutErrors The number of outbound packets that could not be transmitted because of errors OutQLen The length of the output packet queue in packe...

Page 74: ...74 Buttons Click to add a new community entry Click to apply changes Click to undo any changes made locally and revert to previously saved values ...

Page 75: ...ypes are none No SNMP log is created no SNMP trap is sent log Create SNMP log entry when the event is triggered snmptrap Send SNMP trap when the event is triggered logandtrap Create SNMP log entry and sent SNMP trap when the event is triggered Community Specify the community when trap is sent the string length is from 0 to 127 default is public Event Last Time Indicates the value of sysUpTime at t...

Page 76: ...rt wide Object Description System Configuration Mode Indicates if Limit Control is globally enabled or disabled on the switch If globally disabled other modules may still use the underlying functionality but limit checks and corresponding actions are disabled Aging Enabled If checked secured MAC addresses are subject to aging as discussed under Aging Period Aging Period If Aging Enabled is checked...

Page 77: ...e switch can take one of the following actions None Do not allow more than Limit MAC addresses on the port but take no further action Trap If Limit 1 MAC addresses are seen on the port send an SNMP trap If Aging is disabled only one SNMP trap will be sent but with Aging enabled new SNMP traps will be sent every time the limit gets exceeded Shutdown If Limit 1 MAC addresses is seen on the port shut...

Page 78: ...78 Buttons Click to refresh the page Note that non committed changes will be lost Click to apply changes Click to undo any changes made locally and revert to previously saved values ...

Page 79: ...bled or a specific port number and it can t be set when action is permitted The default value is Disabled Mirror Specify the mirror operation of this port The allowed values are Enabled Frames received on the port are mirrored Disabled Frames received on the port are not mirrored The default value is Disabled Logging Specify the logging operation of this port Notice that the logging message doesn ...

Page 80: ...figuration of the ACL user module Disabled To close ports by changing the volatile port configuration of the ACL user module The default value is Enabled Counter Counts the number of frames that match this ACE Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values Click to refresh the page any changes made locally will be undone Click to clear t...

Page 81: ... same row Rate The rate range is located 0 3276700 in pps Or 0 100 200 300 1000000 in kbps Unit Specify the rate unit The allowed values are pps packets per second kbps Kbits per second Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...

Page 82: ...he ACE will match IPv4 frames which are not ICMP UDP TCP IPv6 The ACE will match all IPv6 standard frames Action Indicates the forwarding action of the ACE Permit Frames matching the ACE may be forwarded and learned Deny Frames matching the ACE are dropped Filter Frames matching the ACE are filtered Rate Limiter Indicates the rate limiter number of the ACE The allowed range is 1 to 16 When Disable...

Page 83: ...ring a policy value and bitmask appears Policy Value When Specific is selected for the policy filter you can enter a specific policy value The allowed range is 0 to 255 Policy Bitmask When Specific is selected for the policy filter you can enter a specific policy bitmask The allowed range is 0x0 to 0xff Notice the usage of bitmask if the binary bit value is 0 it means this bit is don t care The re...

Page 84: ...logged Note The logging feature only works when the packet length is less than 1518 without VLAN tags and the System Log memory size and logging rate is limited Shutdown Specify the port shut down operation of the ACE The allowed values are Enabled If a frame matches the ACE the ingress port will be disabled Disabled Port shut down is disabled for the ACE Note The shutdown feature only works when ...

Page 85: ...y the sender IP address and sender IP mask in the SIP Address and SIP Mask fields that appear Sender IP Address When Host or Network is selected for the sender IP filter you can enter a specific sender IP address in dotted decimal notation Sender IP Mask When Network is selected for the sender IP filter you can enter a specific sender IP mask in dotted decimal notation Target IP Filter Specify the...

Page 86: ... this IP protocol value IP TTL Specify the Time to Live settings for this ACE zero IPv4 frames with a Time to Live field greater than zero must not be able to match this entry non zero IPv4 frames with a Time to Live field greater than zero must be able to match this entry Any Any value is allowed don t care IP Fragment Specify the fragment offset settings for this ACE This involves the settings f...

Page 87: ...r the source IPv6 filter you can enter a specific SIPv6 address The field only supported last 32 bits for IPv6 address SIP BitMask When Specific is selected for the source IPv6 filter you can enter a specific SIPv6 mask The field only supported last 32 bits for IPv6 address Notice the usage of bitmask if the binary bit value is 0 it means this bit is don t care The real matched pattern is sipv6_ad...

Page 88: ...N Specify the TCP No more data from sender FIN value for this ACE 0 TCP frames where the FIN field is set must not be able to match this entry 1 TCP frames where the FIN field is set must be able to match this entry Any Any value is allowed don t care TCP SYN Specify the TCP Synchronize sequence numbers SYN value for this ACE 0 TCP frames where the SYN field is set must not be able to match this e...

Page 89: ...matches this EtherType value Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values Return to the previous page 5 3 33 IP Source Guard Configuration This page provides IP Source Guard related configuration ...

Page 90: ...led IP Source Guard is enabled on this given port Max Dynamic Clients Specify the maximum number of dynamic clients that can be learned on given port This value can be 0 1 2 or unlimited If the port mode is enabled and the value of max dynamic client is equal to 0 it means only allow the IP packets forwarding that are matched in static entries on the specific port Buttons Click to apply changes Cl...

Page 91: ... save Port The logical port for the settings VLAN ID The vlan id for the settings IP Address Allowed Source IP address MAC address Allowed Source MAC address Buttons Click to add a new entry to the Static IP Source Guard table Click to apply changes Click to undo any changes made locally and revert to previously saved values ...

Page 92: ...led ARP Inspection is enabled on this given port Possible modes are Enabled Enable ARP Inspection operation Disabled Disable ARP Inspection operation If you want to inspect the VLAN configuration you have to enable the setting of Check VLAN The default setting of Check VLAN is disabled When the setting of Check VLAN is disabled the log type of ARP Inspection will refer to the port setting And the ...

Page 93: ...type of ARP Inspection will refer to the port setting There are four log types and possible types are None Log nothing Deny Log denied entries Permit Log permitted entries ALL Log all entries Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values Click to translate all dynamic entries to static entries ...

Page 94: ...as a basis for the next lookup When the end is reached the warning message is shown in the displayed table Use the button to start over Specify ARP Inspection is enabled on which VLANs First you have to enable the port setting on Port mode configuration web page Only when both Global Mode and Port Mode on a given port are enabled ARP Inspection is enabled on this given port Second you can specify ...

Page 95: ...r the settings VLAN ID The vlan id for the settings MAC Address Allowed Source MAC address in ARP request packets IP Address Allowed Source IP address in ARP request packets Buttons Click to add a new entry to the Static ARP Inspection table Click to apply changes Click to undo any changes made locally and revert to previously saved values ...

Page 96: ...s The will use the last entry of the currently displayed table as a basis for the next lookup When the end is reached the text No more entries is shown in the displayed table Use the button to start over Object Description Port Switch Port Number for which the entries are displayed VLAN ID VLAN ID in which the ARP traffic is permitted MAC Address User MAC address of the entry IP Address User IP ad...

Page 97: ...tch from continually trying to contact a server that it has already determined as dead Setting the Deadtime to a value greater than 0 zero will enable this feature but only if more than one server has been configured Key The secret key up to 63 characters long shared between the RADIUS server and the switch NAS IP Address Attribute 4 The IPv4 address to be used as attribute 4 in RADIUS Access Requ...

Page 98: ...rrides the global timeout value Leaving it blank will use the global timeout value Retransmit This optional setting overrides the global retransmit value Leaving it blank will use the global retransmit value Key This optional setting overrides the global key Leaving it blank will use the global key Buttons Click to add a new RADIUS server up to 5 servers are supported The button can be used to und...

Page 99: ...ver that it has already determined as dead Setting the Deadtime to a value greater than 0 zero will enable this feature but only if more than one server has been configured Key The secret key up to 63 characters long shared between the TACACS server and the switch Server Configuration Delete To delete a TACACS server entry check this box The entry will be deleted during the next Save Hostname The ...

Page 100: ... to add a new TACACS server up to 5 servers are supported The button can be used to undo the addition of the new server Click to apply changes Click to undo any changes made locally and revert to previously saved values ...

Page 101: ...eck to disable By default Destination MAC Address is disabled IP Address The IP address can be used to calculate the destination port for the frame Check to enable the use of the IP Address or uncheck to disable By default IP Address is enabled TCP UDP Port Number The TCP UDP port number can be used to calculate the destination port for the frame Check to enable the use of the TCP UDP Port Number ...

Page 102: ...he aggregation By default no ports belong to any aggregation group Only full duplex ports can join an aggregation and ports must be in the same speed in each group Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...

Page 103: ...e entered Ports with the same Key value can participate in the same aggregation group while ports with different keys cannot Role The Role shows the LACP activity status The Active will transmit LACP packets each second while Passive will wait for a LACP packet from a partner speak if spoken to Timeout The Timeout controls the period between BPDU transmissions Fast will transmit LACP packets each ...

Page 104: ...104 Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...

Page 105: ... loop protections is enabled as a whole Transmission Time The interval between each loop protection PDU sent on each port valid values are 1 to 10 seconds Shutdown Time The period in seconds for which a port will be kept disabled in the event of a loop is detected and the port action shuts down the port Valid values are 0 to 604800 seconds 7 days A value of zero will keep a port disabled until nex...

Page 106: ...ction performed when a loop is detected on a port Valid values are Shutdown Port Shutdown Port and Log or Log Only Tx Mode Controls whether the port is actively generating loop protection PDU s or whether it is just passively looking for looped PDU s Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...

Page 107: ...Bridge Identifier For MSTP operation this is the priority of the CIST Otherwise this is the priority of the STP RSTP bridge Forward Delay The delay used by STP Bridges to transit Root and Designated Ports to Forwarding used in STP compatible mode Valid values are in the range 4 to 30 seconds Max Age The maximum age of the information transmitted by the Bridge when it is the Root Bridge Valid value...

Page 108: ...on of a BPDU The port will enter the error disabled state and will be removed from the active topology Port Error Recovery Control whether a port in the error disabled state automatically will be enabled after a certain time If recovery is not enabled ports have to be disabled and re enabled for normal STP operation The condition is also cleared by a system reboot Port Error Recovery Timeout The t...

Page 109: ...egion The name is at most 32 characters Configuration Revision The revision of the MSTI configuration named above This must be an integer between 0 and 65535 MSTI Mapping MSTI The bridge instance The CIST is not available for explicit mapping as it will receive the VLANs not explicitly mapped VLANs Mapped The list of VLANs mapped to the MSTI The VLANs can be given as a single xx xx being between 1...

Page 110: ...110 Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...

Page 111: ...idge instance The CIST is the default instance which is always active Priorities Controls the bridge priority Lower numeric values have better priority The bridge priority plus the MSTI instance number concatenated with the 6 byte MAC address of the switch forms a Bridge Identifier Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...

Page 112: ...wer path cost ports are chosen as forwarding ports in favor of higher path cost ports Valid values are in the range 1 to 200000000 Priority Controls the port priority This can be used to control priority of ports having identical port cost See above operEdge state flag Operational flag describing whether the port is connecting directly to edge devices No Bridges attached Transition to the forwardi...

Page 113: ...in a spanning tree s active topology as a result of persistently incorrect learned station location information It is set by a network administrator to prevent bridges external to a core region of the network causing address flushing in that region possibly because those bridges are not under the full control of the administrator or the physical link state of the attached LANs transits frequently ...

Page 114: ...ch is instantiated separately for each active CIST physical port for each MSTI instance configured on and applicable to the port The MSTI instance must be selected before displaying actual MSTI port configuration options This page contains MSTI port settings for physical and aggregated ports Click to retrieve settings for a specific MSTI the page displayed as follow ...

Page 115: ...eed using the 802 1D recommended values Using the Specific setting a user defined value can be entered The path cost is used when establishing the active topology of the network Lower path cost ports are chosen as forwarding ports in favor of higher path cost ports Valid values are in the range 1 to 200000000 Priority Controls the port priority This can be used to control priority of ports having ...

Page 116: ...116 Buttons Click to retrieve settings for a specific MSTI Click to apply changes Click to undo any changes made locally and revert to previously saved values ...

Page 117: ...ric characters At least one alphabet must be present Profile Description Additional description which is composed of at maximum 64 alphabetic and numeric characters about the profile No blank or space characters are permitted as part of description Use _ or to separate the description sentence Rule When the profile is created click the edit button to enter the rule setting page of the designated p...

Page 118: ...alphabetic and numeric characters At least one alphabet must be present Start Address The starting IPv4 IPv6 Multicast Group Address that will be used as an address range End Address The ending IPv4 IPv6 Multicast Group Address that will be used as an address range Buttons Click to add new address range Specify the name and configure the addresses Click Save Click to apply changes Click to undo an...

Page 119: ...at send and receive multicast data to and from the multicast VLAN are called MVR source ports It is allowed to create at maximum 4 MVR VLANs with corresponding channel profile for each Multicast VLAN The channel profile is defined by the IPMC Profile which provides the filtering conditions Object Description MVR Mode Enable Disable the Global MVR The Unregistered Flooding control depends on the cu...

Page 120: ...f tenths of a second The range is from 0 to 31744 The default LLQI is 5 tenths or one half second Interface Channel Profile When the MVR VLAN is created select the IPMC Profile as the channel filtering condition for the specific MVR VLAN Summary about the Interface Channel Profiling of the MVR VLAN will be shown by clicking the view button Profile selected for designated interface channel is not a...

Page 121: ...4 Flooding Enabled Enable unregistered IPMCv4 traffic flooding The flooding control takes effect only when IGMP Snooping is enabled When IGMP Snooping is disabled unregistered IPMCv4 traffic flooding is always active in spite of this setting IGMP SSM Range SSM Source Specific Multicast Range allows the SSM aware hosts and routers run the SSM service model for the groups in the address range ...

Page 122: ...hich ports act as router ports A router port is a port on the Ethernet switch that leads towards the Layer 3 multicast device or IGMP querier If an aggregation member port is selected as a router port the whole aggregation will act as a router port Fast Leave Enable the fast leave on the port Throttling Enable to limit the number of multicast groups to which a switch port can belong Buttons Click ...

Page 123: ... value By default this value will be 192 0 2 1 Compatibility Compatibility is maintained by hosts and routers taking appropriate actions depending on the versions of IGMP operating on hosts and routers within a network The allowed selection is IGMP Auto Forced IGMPv1 Forced IGMPv2 Forced IGMPv3 default compatibility value is IGMP Auto PRI Priority of Interface It indicates the IGMP control frame p...

Page 124: ...ault unsolicited report interval is 1 second Buttons Refreshes the displayed table starting from the VLAN input fields Updates the table starting from the first entry in the VLAN Table i e the entry with the lowest VLAN ID Updates the table starting with the entry after the last entry currently displayed Click to add new IGMP VLAN Specify the VID and configure the new entry Click Save The specific...

Page 125: ...the specific port Summary about the designated profile will be shown by clicking the view button Profile Management Button You can inspect the rules of the designated profile by using the following button List the rules associated with the designated profile Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...

Page 126: ...SM service model for the groups in the address range Leave Proxy Enable Enable MLD Leave Proxy This feature can be used to avoid forwarding unnecessary leave messages to the router side Proxy Enable Enable MLD Proxy This feature can be used to avoid forwarding unnecessary join and leave messages to the router side Router Port Specify which ports act as router ports A router port is a port on the E...

Page 127: ...127 Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...

Page 128: ...different classes of traffic The allowed range is 0 best effort to 7 highest default interface priority value is 0 RV Robustness Variable The Robustness Variable allows tuning for the expected packet loss on a link The allowed range is 1 to 255 default robustness variable value is 2 QI Query Interval The Query Interval is the interval between General Queries sent by the Querier The allowed range i...

Page 129: ...from the first entry in the VLAN Table i e the entry with the lowest VLAN ID Updates the table starting with the entry after the last entry currently displayed Click to add new MLD VLAN Specify the VID and configure the new entry Click Save The specific MLD VLAN starts working after the corresponding static VLAN is also created Click to apply changes Click to undo any changes made locally and reve...

Page 130: ...the specific port Summary about the designated profile will be shown by clicking the view button Profile Management Button You can inspect the rules of the designated profile by using the following button List the rules associated with the designated profile Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...

Page 131: ...o 2 10 times Tx Delay If some configuration is changed e g the IP address a new LLDP frame is transmitted but the time between the LLDP frames will always be at least the value of Tx Delay seconds Tx Delay cannot be larger than 1 4 of the Tx Interval value Valid values are restricted to 1 8192 seconds Tx Reinit When a port is disabled LLDP is disabled or the switch is rebooted an LLDP shutdown fra...

Page 132: ... mapped to the LLDP Port ID field CDP TLV Version and Platform is mapped to the LLDP System Description field Both the CDP and LLDP support system capabilities but the CDP capabilities cover capabilities that are not part of the LLDP These capabilities are shown as others in the LLDP neighbors table If all ports have CDP awareness disabled the switch forwards CDP frames received from neighbor devi...

Page 133: ...DP MED Fast Start interaction between the protocol and the application layers on top of the protocol in order to achieve these related properties Initially a Network Connectivity Device will only transmit LLDP TLVs in an LLDPDU Only after an LLDP MED Endpoint Device is detected will an LLDP MED capable Network Connectivity Device start to advertise LLDP MED TLVs in outgoing LLDPDUs on the associat...

Page 134: ...ing and represents ground level at the given latitude and longitude Inside a building 0 0 represents the floor level associated with ground level at the main entrance Map Datum The Map Datum is used for the coordinates given in these options WGS84 Geographical 3D World Geodesic System 1984 CRS Code 4327 Prime Meridian Name Greenwich NAD83 NAVD88 North American Datum 1983 CRS Code 4269 Prime Meridi...

Page 135: ...ng conditional for use in network topologies that require a different policy for the voice signaling than for the voice media This application type should not be advertised if all the same network policies apply as those advertised in the Voice application policy 3 Guest Voice support a separate limited feature set voice service for guest users and visitors with their own IP Telephony handsets and...

Page 136: ...efined by IEEE 802 1Q 2003 VLAN ID VLAN identifier VID for the port as defined in IEEE 802 1Q 2003 L2 Priority L2 Priority is the Layer 2 priority to be used for the specified application type L2 Priority may specify one of eight priority levels 0 through 7 as defined by IEEE 802 1D 2004 A value of 0 represents use of the default priority as defined in IEEE 802 1D 2004 DSCP DSCP value to be used t...

Page 137: ...e is similar to the Class mode expect that each port determine the amount power it reserves by exchanging PoE information using the LLDP protocol and reserves power accordingly If no LLDP information is available for a port the port will reserve power using the class mode In this mode the Maximum Power fields have no effect Power Management Mode Actual Consumption In this mode the ports are shut d...

Page 138: ...f standard Make sure the connected PD supports auto voltage polarity and the operating voltage range is 54V to 40V The Operation mode will be set to 802 3at automatically if Force On mode is selected The operation mode setting will remain at 802 3at even after PoE force on mode is cancelled Operation Mode 802 3af Sets PoE protocol to IEEE 802 3af 802 3at Sets PoE protocol to IEEE 802 3at Priority ...

Page 139: ...our and minute End Select the end hour and minute Action Power On Select the radio button to apply power on during the interval Power Off Select the radio button to apply power off during the interval Power Scheduling During Time Interval There are 48 time interval one day Each interval has 30 minutes Day The current scheduling state is displayed graphically during the week Green indicates the pow...

Page 140: ... on PoE port It is allowed to create at maximum 5 entries for each PoE port Object Description Delete Check to delete the entry The designated entry will be deleted during the next save Day Checkmarks indicate which day are members of the entry Check or uncheck as needed to modify the entry Time hh mm hh Select the hour mm Select the minute Buttons Click to add new reset entry Click to apply chang...

Page 141: ...le Learning Auto Learning is done automatically as soon as a frame with unknown SMAC is received Disable No learning is done Secure Only static MAC entries are learned all other frames are dropped Note Make sure that the link used for managing the switch is added to the Static Mac Table before changing to secure learning mode otherwise the management link is lost and can only be restored by using ...

Page 142: ...ion Global VLAN Configuration Allowed Access VLANs This field shows the allowed Access VLANs i e it only affects ports configured as Access ports Ports in other modes are members of all VLANs specified in the Allowed VLANs field By default only VLAN 1 is enabled More VLANs may be created by using a list syntax where the individual elements are separated by commas Ranges are specified with a dash s...

Page 143: ...mes but frames classified to the Port VLAN a k a Native VLAN get tagged on egress Frames classified to the Port VLAN do not get C tagged on egress Egress tagging can be changed to tag all frames in which case only tagged frames are accepted on ingress Hybrid Hybrid ports resemble trunk ports in many ways but add additional port configuration features In addition to the characteristics described fo...

Page 144: ... a member of Ingress Acceptance Hybrid ports allow for changing the type of frames that are accepted on ingress Tagged and Untagged Both tagged and untagged frames are accepted Tagged Only Only tagged frames are accepted on ingress Untagged frames are discarded Untagged Only Only untagged frames are accepted on ingress Tagged frames are discarded Egress Tagging Ports in Trunk and Hybrid mode may c...

Page 145: ...ice VLAN feature enables voice traffic forwarding on the Voice VLAN then the switch can classify and schedule network traffic It is recommended that there be two VLANs on a port one for voice one for data Before connecting the IP device to the switch the IP phone should configure the voice VLAN ID correctly It should be configured through its own GUI ...

Page 146: ... is a conflict in configuration if the value equals management VID MVR VID PVID etc The allowed range is 1 to 4095 Aging Time Indicates the Voice VLAN secure learning aging time The allowed range is 10 to 10000000 seconds It is used when security mode or auto detect mode is enabled In other cases it will be based on hardware aging time The actual aging time will be situated between the age_time 2 ...

Page 147: ...eration Port Discovery Protocol Indicates the Voice VLAN port discovery protocol It will only work when auto detect mode is enabled We should enable LLDP feature before configuring discovery protocol to LLDP or Both Changing the discovery protocol to OUI or LLDP will restart auto detect process Possible discovery protocols are OUI Detect telephony device by OUI address LLDP Detect telephony device...

Page 148: ...xx x is a hexadecimal digit Description The description of OUI address Normally it describes which vendor telephony device it belongs to The allowed string length is 0 to 32 Buttons Click to add a new access management entry Click to apply changes Click to undo any changes made locally and revert to previously saved values 5 3 67 QoS Port Classification This page allows you to configure the basic ...

Page 149: ...ag Otherwise the frame is classified to the default DPL The classified DPL can be overruled by a QCL entry PCP Controls the default PCP value All frames are classified to a PCP value If the port is VLAN aware and the frame is tagged then the frame is classified to the PCP value in the tag Otherwise the frame is classified to the default PCP value DEI Controls the default DEI value All frames are c...

Page 150: ...150 Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...

Page 151: ...efault value is 500 This value is restricted to 100 1000000 when the Unit is kbps or fps and it is restricted to 1 3300 when the Unit is Mbps or kfps Unit Controls the unit of measure for the policer rate as kbps Mbps fps or kfps The default value is kbps Flow Control If flow control is enabled and the port is in flow control mode then pause frames are sent instead of discarding frames Buttons Cli...

Page 152: ... Port Schedulers for all switch ports Object Description Port The logical port for the settings contained in the same row Click on the port number in order to configure the schedulers Mode Shows the scheduling mode for this port Qn Shows the weight for this queue and port ...

Page 153: ... for all switch ports Object Description Port The logical port for the settings contained in the same row Click on the port number in order to configure the shapers Qn Shows disabled or actual queue shaper rate e g 800 Mbps Port Shows disabled or actual port shaper rate e g 800 Mbps ...

Page 154: ...ject Description Port The logical port for the settings contained in the same row Click on the port number in order to configure tag remarking Mode Shows the tag remarking mode for this port Classified Use classified PCP DEI values Default Use default PCP DEI values Mapped Use mapped versions of QoS class and DP level ...

Page 155: ...ess translation and classification settings for individual ports There are two configuration parameters available in Ingress Translate Classify Translate To Enable the Ingress Translation click the checkbox Classify Classification for a port has 4 different values Disable No Ingress DSCP Classification DSCP 0 Classify if incoming or translated if enabled DSCP is 0 Selected Classify only selected D...

Page 156: ...P value is always taken from the DSCP Translation Egress Remap DP0 table Remap DP Aware DSCP from analyzer is remapped and frame is remarked with remapped DSCP value Depending on the DP level of the frame the remapped DSCP value is either taken from the DSCP Translation Egress Remap DP0 table or from the DSCP Translation Egress Remap DP1 table Buttons Click to apply changes Click to undo any chang...

Page 157: ...157 5 3 73 DSCP Based QoS This page allows you to configure the basic QoS DSCP based QoS Ingress Classification settings for all switches ...

Page 158: ...rames with trusted DSCP values are mapped to a specific QoS class and Drop Precedence Level Frames with untrusted DSCP values are treated as a non IP frame QoS Class QoS class value can be any of 0 7 DPL Drop Precedence Level 0 1 Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...

Page 159: ...ct Description DSCP Maximum number of supported DSCP values are 64 and valid DSCP value ranges from 0 to 63 Ingress Ingress side DSCP can be first translated to new DSCP before using the DSCP for QoS class and DPL map There are two configuration parameters for DSCP Translation Translate Classify Translation DSCP at Ingress side can be translated to any of 0 63 DSCP values ...

Page 160: ...vel 0 Remap DP1 Controls the remapping for frames with DP level 1 Remap DP0 Select the DSCP value from select menu to which you want to remap DSCP value ranges from 0 to 63 Remap DP1 Select the DSCP value from select menu to which you want to remap DSCP value ranges from 0 to 63 Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...

Page 161: ... QoS class and Drop Precedence Level to DSCP value Object Description QoS Class Actual QoS class DPL Actual Drop Precedence Level DSCP Select the classified DSCP value 0 63 Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...

Page 162: ...tagged frames Tagged Match tagged frames The default value is Any VID Indicates VLAN ID either a specific VID or range of VIDs VID can be in the range 1 4095 or Any PCP Priority Code Point Valid values of PCP are specific 0 1 2 3 4 5 6 7 or range 0 1 2 3 4 5 6 7 0 3 4 7 or Any DEI Drop Eligible Indicator Valid value of DEI is 0 1 or Any Frame Type Indicates the type of frame Possible values are An...

Page 163: ...ld can be Untagged Tagged or Any VID Valid value of VLAN ID can be any value in the range 1 4095 or Any user can enter either a specific value or a range of VIDs PCP Valid value PCP are specific 0 1 2 3 4 5 6 7 or range 0 1 2 3 4 5 6 7 0 3 4 7 or Any DEI Valid value of DEI can be 0 1 or Any Frame Type Frame Type can have any of the following values Any Allow all types of frames EtherType Ether Typ...

Page 164: ... IP protocol UDP TCP IPv6 Protocol IP protocol number 0 255 TCP or UDP or Any Source IP 32 LS bits of IPv6 source address in value mask format or Any If a port is configured to match on DMAC DIP this field is the Destination IP address DSCP Diffserv Code Point value DSCP It can be a specific value range of values or Any DSCP values are in the range 0 63 including BE CS1 CS7 EF or AF11 AF43 Sport S...

Page 165: ...ted packet rate for unicast multicast or broadcast traffic across the switch Object Description Frame Type The settings in a particular row apply to the frame type listed here Unicast Multicast or Broadcast Enable Enable or disable the storm control status for the given frame type Rate The rate unit is packets per second pps Valid values are 1 2 4 8 16 32 64 128 256 512 1K 2K 4K 8K 16K 32K 64K 128...

Page 166: ...irrored on a mirror port where a frame analyzer can be attached to analyze the frame flow The traffic to be copied on the mirror port is selected as follows All frames received on a given port also known as ingress or source mirroring All frames transmitted on a given port also known as egress or destination mirroring ...

Page 167: ...ansmitted are not mirrored Tx only Frames transmitted on this port are mirrored on the mirror port Frames received are not mirrored Disabled Neither frames transmitted nor frames received are mirrored Enabled Frames received and frames transmitted are mirrored on the mirror port Note For a given port a frame is only transmitted once It is therefore not possible to mirror mirror port Tx frames Beca...

Page 168: ... 20 Leave time is a value in the range 60 300 in the units of centi seconds i e in units of one hundredth of a second The default is 60 LeaveAll time is a value in the range 1000 5000 in the units of centi seconds i e in units of one hundredth of a second The default is 1000 Max number of VLANs When GVRP is enabled a maximum number of VLANs supported by GVRP is specified By default this number is ...

Page 169: ...169 5 3 80 Port Config This page allows you to enable a port for GVRP Buttons Click to apply changes ...

Page 170: ...will be reset to default Group 3 all configuration options will be locked To configure Group 3 both Group1 and 2 should be disabled first When Group 3 is enabled all configuration of Group1 and 2 will be reset to default Group 1 and 2 all configuration options will be locked Role Configure the Ring group on this switch as specific role Group 1 support option of ring master and ring slave Ring it c...

Page 171: ...n role is dual homing one ring port is primary port and another is backup port This backup port is redundant port it is blocking port in normal state When role is chain head one ring port is member port and another is head port Both ring ports are forwarding port in normal state When role is chain tail one ring port is member port and another is tail port The tail port is redundant port it is bloc...

Page 172: ...re DDMI on this page Object Description Mode Enabled Enable DDMI mode operation Disabled Disable DDMI mode operation Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...

Page 173: ...tem Information System Location MAC Address The MAC Address of this switch Chip ID The Chip ID of this switch System Date The current GMT system time and date The system time is obtained through the Timing server running on the switch if any System Uptime The period of time the device has been operational Software Version The software version of this switch Software Date The date when the switch s...

Page 174: ...load is measured as averaged over the last 100ms 1sec and 10 seconds intervals The last 1 256 samples maximum 256 are graphed and the last numbers are displayed as text as well Buttons Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds ...

Page 175: ...rent address of the interface of the given type Status The status flags of the interface and or address IP Routes Network The destination IP network or host address of this route Gateway The gateway address of this route Status The status flags of the route Neighbor cache IP Address The IP address of the entry Link Address The Link MAC address for which a binding to the IP address given exist Butt...

Page 176: ...r continuous refresh with the same start input field The will use the last entry of the currently displayed table as a basis for the next lookup When the end is reached the text No more entries is shown in the displayed table Use the button to start over Object Description ID The identification of the system log entry Level The level of the system log entry Info The system log entry is belonged in...

Page 177: ...The ID 1 of the system log entry Message The detailed message of the system log entry Buttons Updates the system log entry to the current entry ID Updates the system log entry to the first available entry ID Updates the system log entry to the previous available entry ID Updates the system log entry to the next available entry ID Updates the system log entry to the last available entry ID 5 4 6 Sy...

Page 178: ...wn EEE Shows if EEE is enabled for the port reflects the settings at the Port Power Savings configuration page LP EEE cap Shows if the link partner is EEE capable EEE Savings Shows if the system is currently saving power due to EEE When EEE is enabled the system will powered down if no frame has been received or transmitted in 5 uSec Actiphy Saving Shows if the system is currently saving power due...

Page 179: ...erview of the current switch port states The port states are illustrated as follows RJ45 ports SFP ports State Disabled Down Link Buttons Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to refresh the page ...

Page 180: ...e number of received and transmitted bytes per port Errors The number of frames received in error and the number of incomplete transmissions per port Drops The number of frames discarded due to ingress or egress congestion Filtered The number of received frames filtered by the forwarding process Buttons Click to refresh the page immediately Clears the counters for all ports Check this box to refre...

Page 181: ... for the settings contained in the same row Qn There are 8 QoS queues per port Q0 is the lowest priority queue Rx Tx The number of received and transmitted packets per queue Buttons Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to refresh the page immediately Clears the counters for all ports ...

Page 182: ...n ingress frame if parameters configured are matched with the frame s content Possible actions are CoS Classify Class of Service DPL Classify Drop Precedence Level DSCP Classify DSCP value Conflict Displays Conflict status of QCL entries As H W resources are shared by multiple applications It may happen that resources required to add a QCE may not be available in that case it shows conflict status...

Page 183: ...kets Rx and Tx Broadcast The number of received and transmitted good and bad broadcast packets Rx and Tx Pause A count of the MAC Control frames received or transmitted on this port that have an opcode indicating a PAUSE operation Receive and Transmit Size Counters The number of received and transmitted good and bad packets split into categories based on their respective frame sizes Receive and Tr...

Page 184: ...he number of received frames filtered by the forwarding process 1 Short frames are frames that are smaller than 64 bytes 2 Long frames are frames that are longer than the configured maximum frame length for this port Transmit Error Counters Tx Drops The number of frames dropped due to output buffer congestion Tx Late Exc Coll The number of frames dropped due to excessive or late collisions ...

Page 185: ...ddress The will use the last entry of the currently displayed table as a basis for the next lookup When the end is reached the text No more entries is shown in the displayed table Use the button to start over Object Description MAC Address User MAC address of the entry VLAN ID VLAN ID in which the DHCP traffic is permitted Source Port Switch Port Number for which the entries are displayed IP Addre...

Page 186: ... not match known circuit ID Receive Bad Remote ID The number of packets whose Remote ID option did not match known Remote ID Client Statistics Transmit to Client The number of relayed packets from server to client Transmit Error The number of packets that resulted in error while being sent to servers Receive from Client The number of received packets from server Receive Agent Option The number of ...

Page 187: ... number of NAK option 53 with value 6 packets received and transmitted Rx and Tx Release The number of release option 53 with value 7 packets received and transmitted Rx and Tx Inform The number of inform option 53 with value 8 packets received and transmitted Rx and Tx Lease Query The number of lease query option 53 with value 10 packets received and transmitted Rx and Tx Lease Unassigned The num...

Page 188: ...eived packets from the interface when access management mode is enabled Allowed Packets Number of allowed packets from the interface when access management mode is enabled Discarded Packets Number of discarded packets from the interface when access management mode is enabled Buttons Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to refresh the page ...

Page 189: ... a module that may request Port Security services Abbr A one letter abbreviation of the user module This is used in the Users column in the port status table Port Status Port The port number for which the status applies Click the port number to see the status for this particular port Users Each of the user modules has a column that shows whether that module has enabled Port Security or not A means...

Page 190: ...f currently learned MAC addresses forwarding as well as blocked and the maximum number of MAC addresses that can be learned on the port respectively If no user modules are enabled on the port the Current column will show a dash If the Limit Control user module is not enabled on the port the Limit column will show a dash Buttons Check this box to refresh the page automatically Automatic refresh occ...

Page 191: ...a single row stating No MAC addresses attached is displayed State Indicates whether the corresponding MAC address is blocked or forwarding In the blocked state it will not be allowed to transmit or receive traffic Time of Addition Shows the date and time when this MAC address was first seen on the port Age Hold If at least one user module has decided to block this MAC address it will stay in the b...

Page 192: ... frames Action Indicates the forwarding action of the ACE Permit Frames matching the ACE may be forwarded and learned Deny Frames matching the ACE are dropped Filter Frames matching the ACE are filtered Rate limiter Indicates the rate limiter number of the ACE The allowed range is 1 to 16 When Disabled is displayed the rate limiter operation is disabled Port Redirect Indicates the port redirect op...

Page 193: ...t displayed entry allowing for continuous refresh with the same start address The will use the last entry of the currently displayed table as a basis for the next lookup When the end is reached the text No more entries is shown in the displayed table Use the button to start over Object Description Port Switch Port Number for which the entries are displayed VLAN ID VLAN ID in which the ARP traffic ...

Page 194: ... first displayed entry allowing for continuous refresh with the same start address The will use the last entry of the currently displayed table as a basis for the next lookup When the end is reached the text No more entries is shown in the displayed table Use the button to start over Object Description Port Switch Port Number for which the entries are displayed VLAN ID VLAN ID in which the IP traf...

Page 195: ...ll get re enabled when the dead time expires The number of seconds left before this occurs is displayed in parentheses This state is only reachable when more than one server is enabled RADIUS Accounting Servers The RADIUS server number Click to navigate to detailed statistics for this server IP Address The IP address and UDP port number in IP Address UDP Port notation of this server Status The cur...

Page 196: ...s Other Info This section contains information about the state of the server and the latest round trip time RADIUS Accounting Statistics Packet Counters RADIUS accounting server packet counter There are five receive and four transmit counters Other Info This section contains information about the state of the server and the latest round trip time Buttons Check this box to refresh the page automati...

Page 197: ...g bits but including FCS octets of between 64 and 1518 octets inclusive but had either a bad Frame Check Sequence FCS with an integral number of octets FCS Error or a bad FCS with a non integral number of octets Alignment Error Under Size The total number of packets received that were less than 64 octets Over size The total number of packets received that were longer than 1518 octets Frag The numb...

Page 198: ...tomatic refresh occurs every 3 seconds Click to refresh the page immediately Updates the table starting from the first entry in the Statistics table i e the entry with the lowest ID Updates the table starting with the entry after the last entry currently displayed ...

Page 199: ...mber of good packets received that were directed to a multicast address CRCErrors The total number of packets received that had a length excluding framing bits but including FCS octets of between 64 and 1518 octets inclusive but had either a bad Frame Check Sequence FCS with an integral number of octets FCS Error or a bad FCS with a non integral number of octets Alignment Error Undersize The total...

Page 200: ...particular variable to be sampled Sample Type The method of sampling the selected variable and calculating the value to be compared against the thresholds Value The value of the statistic during the last sampling period Startup Alarm The alarm that may be sent when this entry is first set to valid Rising Threshold Rising threshold value Rising Index Rising event index Falling Threshold Falling thr...

Page 201: ... Index found in the Event table Object Description Event Index Indicates the index of the event entry Log Index Indicates the index of the log entry Log Time Indicates Event log time LogDescription Indicates the Event description Buttons Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to refresh the page immediately Updates the table starting from th...

Page 202: ... GLAGs as aggr id Partner System ID The system ID MAC address of the aggregation partner Partner Key The Key that the partner has assigned to this aggregation ID Last Changed The time since this aggregation changed Local Ports Shows which ports are a part of this aggregation for this switch Buttons Click to refresh the page immediately Check this box to refresh the page automatically Automatic ref...

Page 203: ... group but will join if other port leaves Meanwhile its LACP status is disabled Key The key assigned to this port Only ports with the same key can aggregate together Aggr ID The Aggregation ID assigned to this aggregation group Partner System ID The partner s System ID MAC address Partner Port The partner s port number connected to this port Partner Prio The partner s port priority Buttons Click t...

Page 204: ...P frames have been received at each port LACP Transmitted Shows how many LACP frames have been sent from each port Discarded Shows how many unknown or illegal LACP frames have been discarded at each port Buttons Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to refresh the page immediately Clears the counters for all ports ...

Page 205: ...ort action Transmit The currently configured port transmit mode Loops The number of loops detected on this port Status The current loop protection status of the port Loop Whether a loop is currently detected on the port Time of Last Loop The time of the last loop event detected Buttons Click to refresh the page immediately Check this box to enable an automatic refresh of the page at regular interv...

Page 206: ...e Root Port The switch port currently assigned the root port role Root Cost Root Path Cost For the Root Bridge it is zero For all other Bridges it is the sum of the Port Path Costs on the least cost path to the Root Bridge Topology Flag The current state of the Topology Change Flag of this Bridge instance Topology Change Last The time since last Topology Change occurred Buttons Click to refresh th...

Page 207: ...rt role can be one of the following values AlternatePort BackupPort RootPort DesignatedPort Disabled CIST State The current STP port state of the CIST port The port state can be one of the following values Discarding Learning Forwarding Uptime The time since the bridge port was last initialized Buttons Click to refresh the page immediately Check this box to refresh the page automatically Automatic...

Page 208: ...ber of legacy STP Configuration BPDU s received transmitted on the port TCN The number of legacy Topology Change Notification BPDU s received transmitted on the port Discarded Unknown The number of unknown Spanning Tree BPDU s received and discarded on the port Discarded Illegal The number of illegal Spanning Tree BPDU s received and discarded on the port Buttons Click to refresh the page immediat...

Page 209: ...oins Received The number of Received IGMPv1 Join s IGMPv2 MLDv1 Report s Received The number of Received IGMPv2 Join s and MLDv1 Report s respectively IGMPv3 MLDv2 Report s Received The number of Received IGMPv1 Join s and MLDv2 Report s respectively IGMPv2 MLDv1 Leave s Received The number of Received IGMPv2 Leave s and MLDv1 Done s respectively Buttons Check this box to refresh the page automati...

Page 210: ... will upon a button click assume the value of the first displayed entry allowing for continuous refresh with the same start address The will use the last entry of the currently displayed table as a basis for the next lookup When the end is reached the text No more entries is shown in the displayed table Use the button to start over Object Description VLAN ID VLAN ID of the group Groups Group ID of...

Page 211: ... the displayed table Use the button to start over Object Description VLAN ID VLAN ID of the group Group Group address of the group displayed Port Switch port number Mode Indicates the filtering mode maintained per VLAN ID port number Group Address basis It can be either Include or Exclude Source Address IP Address of the source Currently system limits the total number of IP source addresses for fi...

Page 212: ...eived V2 Reports V3 Report Received The number of Received V3 Reports V2 Leaves Received The number of Received V2 Leaves Router Port Display which ports act as router ports A router port is a port on the Ethernet switch that leads towards the Layer 3 multicast device or IGMP querier Static denotes the specific port is configured to be a router port Dynamic denotes the specific port is learnt to b...

Page 213: ...ssume the value of the first displayed entry allowing for continuous refresh with the same start address The will use the last entry of the currently displayed table as a basis for the next lookup When the end is reached the text No more entries is shown in the displayed table Use the button to start over Object Description VLAN ID VLAN ID of the group Groups Group address of the group displayed P...

Page 214: ...d is reached the text No more entries is shown in the displayed table Use the button to start over Object Description VLAN ID VLAN ID of the group Group Group address of the group displayed Port Switch port number Mode Indicates the filtering mode maintained per VLAN ID port number Group Address basis It can be either Include or Exclude Source Address IP Address of the source Currently system limi...

Page 215: ...eived The number of Received V2 Reports V1 Leaves Received The number of Received V1 Leaves Router Port Display which ports act as router ports A router port is a port on the Ethernet switch that leads towards the Layer 3 multicast device or MLD querier Static denotes the specific port is configured to be a router port Dynamic denotes the specific port is learnt to be a router port Both denote the...

Page 216: ...ume the value of the first displayed entry allowing for continuous refresh with the same start address The will use the last entry of the currently displayed table as a basis for the next lookup When the end is reached the text No more entries is shown in the displayed table Use the button to start over Object Description VLAN ID VLAN ID of the group Groups Group address of the group displayed Por...

Page 217: ... is reached the text No more entries is shown in the displayed table Use the button to start over Object Description VLAN ID VLAN ID of the group Group Group address of the group displayed Port Switch port number Mode Indicates the filtering mode maintained per VLAN ID port number Group Address basis It can be either Include or Exclude Source Address IP Address of the source Currently system limit...

Page 218: ...e advertised by the neighbor unit System Capabilities System Capabilities describes the neighbor unit s capabilities The possible capabilities are 1 Other 2 Repeater 3 Bridge 4 WLAN Access Point 5 Router 6 Telephone 7 DOCSIS cable device 8 Station only 9 Reserved When a capability is enabled the capability is followed by If the capability is disabled the capability is followed by Management Addres...

Page 219: ...l reasons 4 IEEE 802 11 Wireless Access Point 5 Any device that supports the IEEE 802 1AB and MED extensions defined by TIA 1057 and can relay IEEE 802 frames via any method LLDP MED Endpoint Device Definition LLDP MED Endpoint Devices as defined in TIA 1057 are located at the IEEE 802 LAN network edge and participate in IP communication service using the LLDP MED framework Within the LLDP MED End...

Page 220: ... limited to Voice Media Gateways Conference Bridges Media Servers and similar Discovery services defined in this class include media type specific network layer policy discovery LLDP MED Communication Endpoint Class III The LLDP MED Communication Endpoint Class III definition is applicable to all endpoint products that act as end user communication appliances supporting IP media Capabilities inclu...

Page 221: ... Video applications relying on TCP with buffering would not be an intended use of this application type 8 Video Signaling for use in network topologies that require a separate policy for the video signaling than for the video media Policy Policy indicates that an Endpoint Device wants to explicitly advertise that the policy is required by the device Can be either Defined or Unknown Unknown The net...

Page 222: ...negotiation status is disabled the 802 3 PMD operating mode will be determined the operational MAU type field value rather than by auto negotiation Auto negotiation Capabilities Auto negotiation Capabilities shows the link partners MAC PHY capabilities Buttons Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to refresh the page ...

Page 223: ...et to Force On on the port s Power Requested The Power Requested shows the requested amount of power the PD wants to be reserved Power Allocated The Power Allocated shows the amount of power the switch has allocated for the PD Power Used The Power Used shows how much power the PD currently is using Current Used The Power Used shows how much current the PD currently is using Priority The Priority s...

Page 224: ...224 Buttons Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to refresh the page ...

Page 225: ... allocation Systems that do not implement this option default the value to be the same as that of the Receive Tw_sys_tx Echo Tx Tw The link partner s Echo Tx Tw value The respective echo values shall be defined as the local link partner s reflection echo of the remote link partners respective values When a local link partner receives its echoed values from the remote link partner it can determine ...

Page 226: ...226 Buttons Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to refresh the page ...

Page 227: ...ws the number of entries deleted due to Time To Live expiring Local Counters Local Port The port on which LLDP frames are received or transmitted Tx Frames The number of LLDP frames transmitted on the port Rx Frames The number of LLDP frames received on the port Rx Errors The number of received LLDP frames containing some kind of error Frames Discarded If a LLDP frame is received on a port and the...

Page 228: ...999 entries from the MAC table default being 20 selected through the entries per page input field When first visited the web page will show the first 20 entries from the beginning of the MAC Table The first displayed will be the one with the lowest VLAN ID and the lowest MAC address found in the MAC Table The Start from MAC address and VLAN input fields allow the user to select the starting point ...

Page 229: ... are members of the entry Buttons Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Refreshes the displayed table starting from the Start from MAC address and VLAN input fields Flushes all dynamic entries Updates the table starting from the first entry in the MAC Table i e the entry with the lowest VLAN ID and MAC address Updates the table starting with the ...

Page 230: ...onfigure VLAN memberships on the fly The drop down list on the right allows for selecting between showing VLAN memberships as configured by an administrator Admin or as configured by one of these internal software modules The Combined entry will show a combination of the administrator and internal software modules configuration and basically reflects what is actually configured in hardware VLAN ID...

Page 231: ...ty if not overridden by the selected user Ingress Filtering Shows whether a given user wants ingress filtering enabled or not The field is empty if not overridden by the selected user Frame Type Shows the acceptable frame types All Taged Untagged that a given user wants to configure on the port The field is empty if not overridden by the selected user Port VALN ID Shows the Port VLAN ID PVID that ...

Page 232: ...heir position in the drop down list The higher in the list the higher priority If conflicts exist it will be displayed as Yes for the Combined user and the offending software module The Combined user reflects what is actually configured in hardware Buttons Select VLAN Users from this drop down list Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to r...

Page 233: ...current status of ring port s Buttons Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to refresh the page 5 4 53 DDMI Overview Display DDMI overview information on this page Object Description Port DDMI port Vendor Indicates Vendor name SFP vendor name Part Number Indicates Vendor PN Part number provided by SFP vendor Serial Number Indicates Vendor S...

Page 234: ...s Transceiver compatibility DDMI Information Current The current value of temperature voltage TX bias TX power and RX power High Alarm Threshold The high alarm threshold value of temperature voltage TX bias TX power and RX power High Warn Threshold The high warn threshold value of temperature voltage TX bias TX power and RX power Low Warn Threshold The low warn threshold value of temperature volta...

Page 235: ...t Values range from 2 bytes to 1452 bytes Ping Count The count of the ICMP packet Values range from 1 time to 60 times Ping Interval The interval of the ICMP packet Values range from 0 second to 30 seconds Egress Interface only for IPv6 The VLAN ID VID of the specific egress IPv6 interface which ICMP packet goes The given VID ranges from 1 to 4094 and will be effective only when the corresponding ...

Page 236: ...inds the best match interface for destination Do not specify egress interface for loopback address Do specify egress interface for link local or multicast address Buttons Click to start transmitting ICMP packets Click to re start diagnostics with PING ...

Page 237: ...e interval of the ICMP packet Values range from 0 second to 30 seconds Egress Interface only for IPv6 The VLAN ID VID of the specific egress IPv6 interface which ICMP packet goes The given VID ranges from 1 to 4094 and will be effective only when the corresponding IPv6 interface is valid When the egress interface is not given PING6 finds the best match interface for destination Do not specify egre...

Page 238: ...238 Click to re start diagnostics with PING ...

Page 239: ...status table Note that VeriPHY is only accurate for cables of length 7 140 meters 10 and 100 Mbps ports will be linked down while running VeriPHY Therefore running VeriPHY on a 10 or 100 Mbps management port will cause the switch to stop responding until VeriPHY is complete After pressing following table show up Object Description Port The port where you are requesting VeriPHY Cable Diagnostics Ca...

Page 240: ... short to pair C Short D Cross pair short to pair D Cross A Abnormal cross pair coupling with pair A Cross B Abnormal cross pair coupling with pair B Cross C Abnormal cross pair coupling with pair C Cross D Abnormal cross pair coupling with pair D Length The length in meters of the cable pair The resolution is 3 meters Buttons Click to run the diagnostics ...

Page 241: ...tenance 5 6 1 Restart Device You can restart the stack switch on this page After restart the stack switch will boot normally Buttons Click to restart device Click to return to the Port State page without restarting ...

Page 242: ...on this page Only the IP configuration is retained The new configuration is available immediately which means that no restart is necessary Buttons Click to reset the configuration to Factory Defaults Click to return to the Port State page without resetting the configuration ...

Page 243: ...the software image is uploaded a page announces that the firmware update is initiated After about a minute the firmware is updated and the switch restarts Warning While the firmware is being updated Web access appears to be defunct The front LED flashes Green Off with a frequency of 10 Hz while the firmware update is in progress Do not restart or power off the device at this time or the switch may...

Page 244: ...ate Image button is also disabled 2 If the alternate image is active due to a corruption of the primary image or by manual intervention uploading a new firmware image to the device will automatically use the primary image slot and activate this 3 The firmware version and date information may be empty for older firmware releases This does not constitute an error Object Description Image The flash i...

Page 245: ...245 Buttons Click to use the alternate image This button may be disabled depending on system state Cancel activating the backup image Navigates away from this page ...

Page 246: ...ring that the currently active configuration will be used at the next reboot 5 6 6 Download It is possible to download any of the files on the switch to the web browser Select the file and click Download running config may take a little while to complete as the file must be prepared for download ...

Page 247: ...g config the file will be applied to the switch configuration This can be done in two ways Replace mode The current configuration is fully replaced with the configuration in the uploaded file Merge mode The uploaded file is merged into running config If the file system is full i e contains the three system files mentioned above plus two other files it is not possible to create new files but an exi...

Page 248: ...t the file to activate and click This will initiate the process of completely replacing the existing configuration with that of the selected file 5 6 9 Delete It is possible to delete any of the writable files stored in flash including startup config If this is done and the switch is rebooted without a prior Save operation this effectively resets the switch to default configuration ...

Page 249: ...t This device complies with Part 15 of FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operations Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equ...

Page 250: ... the right supply voltage for example 110V AC in North America or 230V AC in Europe DO NOT remove the plug and connect it to a power outlet by itself always attach the plug to the power adaptor first before connecting it to a power outlet Use ONLY power wires of the appropriate wire gauge for your device Connect it to a power supply of the correct voltage Do NOT allow anything to rest on the power...

Page 251: ...omento de desechar el producto la recogida por separado éste y o su batería ayudará a salvar los recursos naturales y a proteger la salud humana y medioambiental Le symbole ci dessous signifie que selon les réglementations locales votre produit et ou sa batterie doivent être éliminés séparément des ordures ménagères Lorsque ce produit atteint sa fin de vie amenez le à un centre de recyclage Au mom...

Page 252: ...252 台灣 警告使用者 ...

Page 253: ...or components to proper operating condition Any replacement will consist of a new or re manufactured functionally equivalent product of equal or higher value and will be solely at the discretion of Zyxel This warranty shall not apply if the product has been modified misused tampered with damaged by an act of God or subjected to abnormal working conditions Note Repair or replacement as provided und...

Page 254: ...n you contact an office Required Information Product model and serial number Warranty Information Date that you received your device Brief description of the problem and the steps you took to solve it Corporate Headquarters Worldwide Taiwan Zyxel Communications Corporation http www zyxel com Asia China Zyxel Communications Shanghai Corp Zyxel Communications Beijing Corp Zyxel Communications Tianji...

Page 255: ...xel com ph Singapore Zyxel Singapore Pte Ltd http www zyxel com sg Taiwan Zyxel Communications Corporation http www zyxel com tw zh Thailand Zyxel Thailand Co Ltd http www zyxel co th Vietnam Zyxel Communications Corporation Vietnam Office http www zyxel com vn vi Europe Austria Zyxel Deutschland GmbH http www zyxel de Belarus Zyxel BY http www zyxel by ...

Page 256: ...ications Czech s r o http www zyxel cz Denmark Zyxel Communications A S http www zyxel dk Estonia Zyxel Estonia http www zyxel com ee et Finland Zyxel Communications http www zyxel fi France Zyxel France http www zyxel fr Germany Zyxel Deutschland GmbH http www zyxel de Hungary Zyxel Hungary SEE http www zyxel hu Italy Zyxel Communications Italy http www zyxel it ...

Page 257: ...yxel nl Norway Zyxel Communications http www zyxel no Poland Zyxel Communications Poland http www zyxel pl Romania Zyxel Romania http www zyxel com ro ro Russia Zyxel Russia http www zyxel ru Slovakia Zyxel Communications Czech s r o organizacna zlozka http www zyxel sk Spain Zyxel Communications ES Ltd http www zyxel es Sweden Zyxel Communications http www zyxel se ...

Page 258: ...ua zyxel com Latin America Argentina Zyxel Communication Corporation http www zyxel com ec es Brazil Zyxel Communications Brasil Ltda https www zyxel com br pt Ecuador Zyxel Communication Corporation http www zyxel com ec es Middle East Israel Zyxel Communication Corporation http il zyxel com homepage shtml Middle East Zyxel Communication Corporation http www zyxel com me en ...

Page 259: ...ica USA Zyxel Communications Inc North America Headquarters http www zyxel com us en Oceania Australia Zyxel Communications Corporation http www zyxel com au en Africa South Africa Nology Pty Ltd http www zyxel co za ...

Reviews: