background image

A. Overview

The RGS200-12P Managed Rugged switch is designed for 
supporting environmental hardening application. Managed switches 
are easier to prioritize, partition, and organize user’s network, 
providing a more reliable and better quality services.

B. Dimension Illustration

RGS200-12P

127,3

[5.0]

28,3

[1.1]

19,9 [0.8]

30,5

[1.2]

30,5

[1.2]

15,1

[0.6]

14,7

[0.6]

47,2

[1.9]

9,6 [0.4]

53,0 [1.4]

13,1 [0.5]

61,0 [2.4]

55,9 [2.2]

12,0 [0.5]

35,0 [1.4]

77,0

[3.0] 24,0

[0.9]

11,0

[0.4]7,0

[0.3]

7,0

[0.3]

11,0

[0.4]

25,0

[1.0]

154,0 [6.1]

C. DIN-Rail Mounting

Mounting step:

1. Screw the DIN-Rail bracket on with the bracket and screws in the 
    accessory kit.
2. Hook the unit over the DIN rail.
3. Push the bottom of the unit towards the DIN Rail until it locks in 
    place.

D. Wall Mounting

Screw the wall-mount brackets with screws in the accessory kit.

M4 SCREW

77,0

[3.0]

154,0 [6.1]

172,0 [6.8]

E. Connecting Power Terminal Block

The switch can be powered from two power supplies (input range 
12V – 58V). Insert the positive and negative wires into V+ and V- 
contacts on the terminal block respectively and tighten the 
wire-clamp screws to prevent the wires from being loosened.

    The DC power should be connected to a well-fused 
    power supply.

    Input power should be within the range of 54~58VDC for PoE+ 
    compliant, or 48-58VDC for PoE compliant.

Second Power Supply

First Power Supply

RGS200-12P Rugged Switch

Quick Start Guide

F. Alarm Relay and Ground

The alarm relay output contacts are in the middle of the DC terminal 
block connector as shown in the figure below.

The alarm relay out is “Normal Open”, and it will be closed when 
detected any predefined failure such as power failures or Ethernet 
link failures. 

The relay output with current carrying capacity of 0.5A @ 24 VDC

Extra Power System

Alarm System

Ground Connector

G. Console Connection

•  DB9 connector connect to computer COM port

•  Baud rate: 115200bps

•  8 data bits, 1 stop bit

•  No Parity

•  None flow control

H. Connect & Login to Managed Switch

1. Connecting to the Ethernet port (RJ45 Ethernet port) of Managed 
    Switch.

2. 

Factory default IP: 192.168.1.1

3. Login with default account and password. 
    

Username: admin                               

    Password: 1234

Copyright © 2016 Zyxel Communications Corp. All Rights Reserved

EU Importer

Zyxel Communication A/S Generatorvej 8D, 2860 Søborg, Denmark.

http://www.zyxel.dk

US Importer

Zyxel Communications, Inc 1130 North Miller Street Anaheim, CA 92806-2001

http://www.us.zyxel.com

This equipment is intended to be used in a Restricted Access 

Location, with access limited to SERVICE PERSONAL and USERS 

authorized to be in that location.