XS3900-48F User’s Guide
224
C
H A P T E R
2 6
VLAN Mapping
This chapter shows you how to configure VLAN mapping on the Switch.
26.1 VLAN Mapping Overview
With VLAN mapping enabled, the Switch can map the VLAN ID and priority level of packets received
from a private network to those used in the service provider’s network.
The Switch checks incoming traffic from the switch ports (non-management ports) against the
VLAN mapping table first, the MAC learning table and then the VLAN table before forwarding them
through the Gigabit uplink port. When VLAN mapping is enabled, the Switch discards the tagged
packets that do not match an entry in the VLAN mapping table. If the incoming packets are
untagged, the Switch adds a PVID based on the VLAN setting.
Note: You can not enable VLAN mapping and VLAN stacking at the same time.
26.1.1 VLAN Mapping Example
In the following example figure, packets that carry VLAN ID 12 and are received on port 3 match a
pre-configured VLAN mapping rule. The Switch translates the VLAN ID from 12 into 123 before
forwarding the packets. Any packets carrying a VLAN tag other than 12 (such as 10) and received
on port 3 will be dropped.
Figure 125
VLAN mapping example
Port 3
12
10
123
10
Service Provider
Network
Summary of Contents for XS-3900-48F
Page 15: ...15 PART I User s Guide ...
Page 16: ...16 ...
Page 48: ...Chapter 2 Tutorials XS3900 48F User s Guide 48 ...
Page 62: ...Chapter 4 The Web Configurator XS3900 48F User s Guide 62 ...
Page 63: ...63 PART II Technical Reference ...
Page 64: ...64 ...
Page 227: ...Chapter 26 VLAN Mapping XS3900 48F User s Guide 227 ...
Page 320: ...Appendix A Common Services XS3900 48F User s Guide 320 ...
Page 332: ...Index XS3900 48F User s Guide 332 ...