Chapter 37 Diagnostic
XS1930 Series User’s Guide
315
Pair status
Ok
: The physical connection between the wire-pair is okay.
Open
: There is no physical connection (an open circuit detected) between the wire-pair.
Short
: There is an short circuit detected between the wire-pair.
Unknown
: The Switch failed to run cable diagnostics on the cable connected this port.
Unsupported
: The port is a fiber port or it is not active.
Cable length
This displays the total length of the Ethernet cable that is connected to the port when the
Pair status
is
Ok
and the Switch chipset supports this feature.
This shows
N/A
if the
Pair status
is
Open
or
Short
. Check the
Distance to fault
.
This shows
Unsupported
if the Switch chipset does not support to show the cable length.
Distance to
fault
This displays the distance between the port and the location where the cable is open or
shorted.
This shows
N/A
if the
Pair status
is
Ok
.
This shows
Unsupported
if the Switch chipset does not support to show the distance.
Locator LED
Enter a time interval (in minutes) and click
Blink
to show the actual location of the Switch
between several devices in a rack.
The default time interval is 30 minutes.
Click
Stop
to have the Switch terminate the blinking locater LED.
Table 165 Management > Diagnostic (continued)
LABEL
DESCRIPTION