www.2n.cz
2N SIP Speaker Horn
®
SIP audio
Installation Manual
Version:
2.9
Page 1: ...www 2n cz 2N SIP Speaker Horn SIP audio Installation Manual Version 2 9...
Page 2: ...ademarks and or trademarks or brands protected by law 2N TELEKOMUNIKACE a s administers the FAQ database to help you quickly find information and to answer your questions about 2N products and service...
Page 3: ...nstallation 2 1 Before You Start 2 2 Mechanical Installation 2 3 Electric Installation 2 4 Product Description 3 Function and Use 3 1 Configuration 3 2 Default Reset 3 3 Basic Functions 3 4 Downloads...
Page 4: ...2N TELEKOMUNIKACE a s www 2n cz 4 44 1 Product Overview Here is what you can find in this section 1 1 Components and Associated Products 1 2 Terms and Symbols...
Page 5: ...enhance camera systems at parking lots public spaces and industrial objects They can work as standalone units or be simply interconnected with existing VMS phone systems via IP VoIP PBX Thanks to PoE...
Page 6: ...ation with VMS Noise detector Easy installation with only one cable Audio PoE VoIP PBX support SIP Excellent reliability through automated audio tests Integrated administration web server Streamed aud...
Page 7: ...2N TELEKOMUNIKACE a s www 2n cz 7 44 Basic Features 10 100Base TX LAN interface 24 V DC 2 A or PoE 802 3af supply Integrated 8 25 W amplifier depending on power supply...
Page 8: ...2N TELEKOMUNIKACE a s www 2n cz 8 44 1 1 Components and Associated Products Basic Unit 2N Part No 914422E Axis Part No 01433 001 2N SIP Speaker Horn...
Page 9: ...E injector without cable PoE injector with EU cable PoE injector with US cable For power supply of intercom via ethernet cable when PoE switch is not available Part No 914423E Axis Part No 01696 001 S...
Page 10: ...40 is the successor to the popular GXV3140 model which allows comfortable video calls in the IP network Touchscreen and keyboard control 91378358 2N Part No Axis Part No 01421 001 Grandstream GXV3275...
Page 11: ...tput Standalone IP device which can be controlled by HTTP commands sent by Helios IP intercom which can thus control devices on unlimited distance 2N Part No 9137411E Axis Part No 01398 001 External I...
Page 12: ...oor intercom to connect any IP device You don t have to configure anything and you only need one unit at each end of the cable and a 2N 2Wire power source connected to at least one of these units The...
Page 13: ...l Safety Always abide by this information to prevent persons from injury Warning Always abide by this information to prevent damage to the device Caution Important information for system functionality...
Page 14: ...on and Installation In this section we describe the product and its 2N SIP Speaker Wall Mounted installation Here is what you can find in this section 2 1 Before You Start 2 2 Mechanical Installation...
Page 15: ...2N TELEKOMUNIKACE a s www 2n cz 15 44 Product Completeness Check Before installing this product check whether the product delivery includes 1x 2N SIP Speaker Horn 1x cable bushing Quick User Manual...
Page 16: ...llation Surface Mounting To mount your unit on a wall or another solid surface 2N SIP Speaker Wall Mounted use the speaker holder Fit this holder with screws to keep the device in place Follow the fig...
Page 17: ...e unit and prevent water from getting to the motherboard in order to avoid the motherboard damage Tip You can pull the network cable including the RJ 45 terminal through a big cable bushing as shown b...
Page 18: ...2N TELEKOMUNIKACE a s www 2n cz 18 44 Insert the case first then insert the seal and pull the UTP cable through the seal Having pulled the cable through place the case with the seal as shown...
Page 19: ...2N TELEKOMUNIKACE a s www 2n cz 19 44 Now the unit is protected against water infiltration...
Page 20: ...n avoid equipment damage or electrical injury Connect the aditional microphone Connect the UTP cable Connect a 24 V power supply unless PoE is used Caution Be sure to connect the power supply as the l...
Page 21: ...ker Horn can be connected to a standard local area network using a LAN interface via the RJ 45 connector on the back panel Always use CAT 5d or higher class cables for reliability reasons LAN Connecti...
Page 22: ...Horn Caution We recommend the use of a LAN surge protection We recommend the use of a shielded SSTP Ethernet cable Power Supply Connection SIP 2N Speaker Horn can be fed using active network elements...
Page 23: ...an adapter other than the recommended one do not exceed the nominal supply voltage value of 24 V Also make sure that the supply voltage polarity is correct Exceeding nominal values and or incorrect co...
Page 24: ...uarantees compatibility with all SIP based systems Use an integrated web interface for configuration 2N SIP Speaker Horn Apply the to search all the units 2N Helios IP Network Scanner 2N SIP Speaker H...
Page 25: ...5 44 3 Function and Use This section provides the basic and extended functions of the 2N SIP Speaker Wall product Mounted Here is what you can find in this section 3 1 Configuration 3 2 Default Reset...
Page 26: ...Scanner The purpose of this application is to find the dynamic IP address of 2N SIP Speaker in the local IP network The application can be downloaded from the 2N web Horn sites www 2n cz Run the insta...
Page 27: ...Login subsection 2N SIP Speaker Horn below Login In the web browser enter the IP address of Subsequently a 2N SIP Speaker Horn login screen will be displayed The default login username and password ar...
Page 28: ...he IP address entered or if applicable check the way the IP address was obtained as described at the beginning of subsection 3 1 Configuration Language Selection You can select the language using the...
Page 29: ...otten password and so on Reset Button Located among the main unit connectors the Reset button helps you reset the factory default values restart the device find the device IP address and switch the st...
Page 30: ...til the red and green LEDs go on simultaneously on the device and the acoustic signal can be heard approx 15 35 s Wait until the red LED goes off and the acoustic signal can be heard approx for anothe...
Page 31: ...elease the RESET button Factory Reset Follow the instructions below to reset the factory default values Press and hold the RESET button Wait until the red and green LEDs go on simultaneously and the a...
Page 32: ...are 2 18 or higher it is necessary to reprogram the using the instructions from section 2N Security Relay 2 4 Device Restart Press the RESET button shortly 1 s to restart the system without changing c...
Page 33: ...ble user group ringing in an office Refer to the Scheduler subsection for activation code settings Configuration Manual Calendar deactivated Used for calendar deactivation Use this function for exampl...
Page 34: ...ne combination Disconnected from LAN IP address lost This tone combination signals that the UTP cable has been disconnected from 2N SIP Speaker Horn Invalid telephone number or invalid switch activati...
Page 35: ...et a call time limit in to avoid call 2N SIP Speaker Horn blocking Push a button on your VoIP telephone to prolong the call Connected call when calling from a telephone to 2N SIP Speaker Horn When cal...
Page 36: ...2N TELEKOMUNIKACE a s www 2n cz 36 44 3 4 Downloads Software 2N Helios IP network scanner 3 0 4...
Page 37: ...100BASE TX with Auto MDIX function Supported protocols SIP2 0 SIPS TLS DHCP opt 66 SMTP 802 1x RTSP RTP SRTP TFTP HTTP HTTPS Syslog ONVIF Operating temperature 30 C to 60 C 22 F to 140 F Operating hu...
Page 38: ...2N TELEKOMUNIKACE a s www 2n cz 38 44 Bias voltage 1 5 V Impedance 2 2 kOhm Output Power 8 W PoE 25 W 24 V Audiocodecs G 711 PCMA PCMU G 722 L16 16 kHz 400 Hz 7 5 kHz 10 dB 275 Hz 12 kHz 20 dB...
Page 39: ...N TELEKOMUNIKACE a s www 2n cz 39 44 5 Supplementary Information Here is what you can find in this section 5 1 Troubleshooting 5 2 Directives Laws and Regulations 5 3 General Instructions and Cautions...
Page 40: ...2N TELEKOMUNIKACE a s www 2n cz 40 44 5 1 Troubleshooting For the most frequently asked questions refer to faq 2n cz...
Page 41: ...s and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that int...
Page 42: ...n of the product caused by incompetent replacement of parts or due to the use of reproduction parts or components The manufacturer shall not be liable and responsible for any loss or damage incurred a...
Page 43: ...c Waste and Used Battery Pack Handling Do not place used electric devices and battery packs into municipal waste containers An undue disposal thereof might impair the environment Deliver your expired...
Page 44: ...2N TELEKOMUNIKACE a s www 2n cz 44 44 2N TELEKOMUNIKACE a s Mod ansk 621 143 01 Prague 4 Czech Republic Phone 420 261 301 500 Fax 420 261 301 599 E mail sales 2n cz Web www 2n cz v2 9...