background image

PF300A12DAASS

CI-01-ASP-DAASS

 
 

 
 
 
 
 

CCTV INSTALLTION SYSTEM 

SINGLE CHANNEL

 

for transmission of Power, Video,   

Two-Way Audio, Control Data   

and Two-Way Security/Fire Alarm Signals

   

 
 
 
 
 
 
 
 

 

 

 
 

 

 

   

 

Mixer                                    Signal Processor

 

 

User Manual 

 

 

Summary of Contents for CI-01-ASP-DAASS

Page 1: ... PF300A12DAASS CI 01 ASP DAASS CCTV INSTALLTION SYSTEM SINGLE CHANNEL for transmission of Power Video Two Way Audio Control Data and Two Way Security Fire Alarm Signals Mixer Signal Processor User Manual ...

Page 2: ...ckage of System Content Product contents One unit of CI 01 ASP DAASS Single Channel Signal Processor One unit of PF300A12DAASS Mixer One unit of 48V 1 65A External Power Supply Adaptor for Signal Processor User Manual Note This package is only one part of CCTV installation package must work with the Associated Equipment for complete CCTV System For instructions regarding the connection of the asso...

Page 3: ...t the surveillance site 2 Signal Processor PN CI 01 ASP DAASS The Signal processor should be installed at Control room next to DVR Monitor 3 Power Supply Model NO SMPS48V1 65A camera Power up to 24W Thickness 35mm 1 3 8in 96mm 3 3 4in 70mm 2 3 4in PF300A12DAASS Thickness 35mm 1 3 8in 96mm 3 3 4in 70mm 2 3 4in CI 01 ASP DAASS ...

Page 4: ...ucting wire made by copper plated steel wire is not suitable for use Note To achieve best performance of the 2Y LINK System the main points for standard Cat 5 cable must be noted as follows 1 DC resistance 10 Ohm 100m 330ft 2 For Cat 5 cable wiring connection RJ45 connector should be used according to usual computer network standard TIA EIA 568 B as below ...

Page 5: ...r 12V DC 100 920 mA 1 2 11W 920 1300mA 11W 15 6W 1300 1600mA 15 6 19 2W 1600 2000mA 19 2 24W Distance 500m 1640ft 400m 1312ft 300m 980ft 200m 650ft Surveillance Site Control Room Power Adapter SMPS48V1 65A Signal Processor CI 01 ASP DAASS Mixer PF300A12DAASS ...

Page 6: ...impedance 600 3000 Ohm and DC operating voltage 9 15 Volt Band Width 10 MHz Max Distance 500 m 1640 ft Connecting Ports Video Input to Mixer BNC Plug Video Output from Signal Processor BNC Plug Power Video Audio data RS485 Alarm I O between Mixer and Signal Processor RJ45 Sockets Power Supply to Camera Terminal Audio Data and Power Supply to Microphone Terminal Alarm Input Output Terminal Data RS4...

Page 7: ...al Connecting to terminals of PTZ Camera for controlling the movement of PTZ Camera Microphone Terminals 2Y LINK Mixer Microphone PVA MIC or Microphone with Output impedance 600 3000 Ohm and DC operating voltage 9 15 Volt For connecting to 8 Ohm speaker AUDIO OUT Terminals Detail Overview Mixer PF300A12DAASS ...

Page 8: ...ting DC12V up to 2A To indicate that the AC DC adaptor is in proper working order Alarm output 12V 50mA showing a triggering signal from signal processor For Connecting the security Fire alarm units at triggering state of signal processor the units are in close status For connections to Signal Processor transmission of Power Video and Data Signals using Cat 5 Cable Detail Overview Mixer PF300A12DA...

Page 9: ...s AUDIO OUT Terminals For connecting to Audio input of DVR For connecting to Audio amplifier with input impedance 10K 40K ohm AUDIO OUT Terminals Connecting to Data Control unit with a pair of cab for controlling PTZ Camera For connecting to DVR or CCTV Monitor Detail Overview Signal Process CI01 ASP DAASS ...

Page 10: ...pness Colour of the images on the CCTV monitor if required DC Power Inlet Terminals 11 Microphone Terminals 2Y LINK Microphone PVA MIC or microphone with output impedance 600 3000 Ohm and DC operating voltage 9 15 Volt Alarm Output Terminals Alarm Input Terminals Alarm output 12V 50mA showing a triggering signal from Mixer For Connecting the security Fire alarm units at triggering state of Mixer t...

Page 11: ...rly grounded 4 The LED lights in RJ45 sockets and Power indicator are on but there is no picture shown on the monitor screen The signal processor video output cable or socket is not properly connected to the DVR or Monitor To make sure the signal processor video output cable or socket is not properly connected to the DVR or Monitor 5 There is no movement of the PTZ Camera when the control keypad i...

Page 12: ...oper maintenance or modification ii parts or supplies not provided or supported iii operation outside the product s specifications or iv unauthorized modification or misuse SHALL NOT BE LIABLE FOR THE LOSS OR DESTRUCTION OF VIDEO IMAGE OR DATA RESULTING FROM THE USE OR SERVICE OF THIS PRODUCT WHETHER DUE TO VIRUS ISSUES OR OTHERWISE OR ANY FAILURE TO SECURE ALL VIDEO IMAGE AND DATA TRANSMITTED OR ...