background image

 

®

 

E

 

THER

 

L

 

INK

 

 

 III 

P

 

ARALLEL

 

 T

 

ASKING

 

 

 

 

EISA B

 

US

 

 M

 

ASTER

 

 

N

 

ETWORK

 

 A

 

DAPTERS

 

 

U

 

SER

 

 G

 

UIDE

 

Members of the 3Com EtherLink III family of 

adapters

 

Part No. 09-0666-001 
Published October 1995

Summary of Contents for III

Page 1: ...ETHERLINK III PARALLEL TASKING EISA BUS MASTER NETWORK ADAPTERS USER GUIDE Members of the 3Com EtherLink III family of adapters Part No 09 0666 001 Published October 1995...

Page 2: ...th in subparagraph a through d of the Commercial Computer Software Restricted Rights Clause at 48 C F R 52 227 19 and the limitations set forth in 3Com s standard commercial agreement for the software...

Page 3: ...ery best 3Com service and support take the time to complete the product registration card Any defective 3Com adapter will be repaired or replaced at 3Com s option for as long as the adapter resides in...

Page 4: ...nds France Israel 3Com France Marketing Department Immeuble McKinley BP 965 1 Avenue de l Atlantique 91976 Les Ulis Courtaboeuf Cedex France Germany Austria Switzerland 3Com GmbH Marketing Department...

Page 5: ...work 2 5 Connecting to the On board Transceiver 2 5 Connecting to Thin Ethernet Cable 2 5 Connecting to Twisted pair Cable 2 6 Connecting to an External Transceiver 2 6 Auto Select Media Type 2 8 3 CO...

Page 6: ...15 NDIS Drivers 4 15 Additional Drivers 4 16 Using Transcend PC Link SmartAgent Software 4 16 Desktop Management Interface 4 17 5 PERFORMING TROUBLESHOOTING AND DIAGNOSTIC TESTS Troubleshooting with...

Page 7: ...Access by Modem B 1 World Wide Web Site B 2 ThreeComForum on CompuServe B 2 3ComFacts Automated Fax Service B 2 Support from Your Network Supplier B 3 Returning Products for Repair B 4 GLOSSARY INDEX...

Page 8: ...2 7 2 5 Connecting the AUI Cable 2 7 3 1 Adapter Configuration Overview 3 1 3 2 Auto Installation Screen 3 7 3 3 Main Menu 3 7 3 4 Multiple Adapter Option Configuration 3 9 3 5 Changing Adapter Optio...

Page 9: ...cons 2 1 1 3C592 EISA Adapter Cable and Connector Specifications 1 2 2 1 Connectors for 3C592 EISA Adapters 2 5 3 1 Software Configuration Options 3 4 4 1 Accessing DOS 4 3 5 1 Diagnostic Programs 5 7...

Page 10: ...Use This Guide The following table shows where to find specific information in this guide If you are looking for Turn to Information about the 3Com EISA bus master network adapters Chapter 1 Instructi...

Page 11: ...r example print autolink log Keys When specific keys are referred to in the text they are called out by their labels such as the Return key or the Escape key or they may be shown as Return or Esc If t...

Page 12: ...on the backplates as shown in Figure 1 1 The name 3C592 EISA adapter is used in this guide to refer to both EtherLink III 10 Mbps EISA adapters unless otherwise specified The bus master drivers suppli...

Page 13: ...stalls and configures all Novell NetWare DOS ODI client software into your operating system Automatic adapter recognition for computers running the Windows 95 network operating system RJ 45 connector...

Page 14: ...ace DMI which increases the manageability of PCs by standardizing how information relating to PCs is made available and how it is accessed LED notification of link integrity and polarity reversal The...

Page 15: ...Figure 2 1 Hardware Installation Overview After installing the adapter you can load the network drivers as described in Chapter 4 If necessary you can change the software option default settings as ex...

Page 16: ...ain the following items 3Com EtherLink III Parallel Tasking EISA bus master adapter EtherLink III Parallel Tasking EISA Bus Master Network Adapters User Guide 3C59X EtherDisk diskette 2 Verify that yo...

Page 17: ...ts are longer than PCI slots and deeper than ISA slots Figure 2 2 PCI and EISA Bus Slots in an EISA Computer The adapter backplate should be flush with the computer chassis Be sure that the connector...

Page 18: ...ears arranged by type 5 Click the Network Adapters tab The name of the installed 3Com adapter appears as shown below 3Com EtherLink III Bus Master EISA Ethernet Adapter This confirms the adapter s ins...

Page 19: ...ter is equipped with an on board transceiver to allow easy connection to the network Connecting to Thin Ethernet Cable The 3C592 COMBO adapter is factory set to use the on board transceiver as the def...

Page 20: ...connector on the end of the twisted pair cable with the notch on the adapter s plug and insert it into the adapter socket The next step is to load the drivers as explained in Chapter 3 Connecting to a...

Page 21: ...can confirm the network connection by double clicking the Network Neighborhood icon The presence of the Entire Network icon in the display box confirms the network connection Figure 2 4 Slide Latch F...

Page 22: ...stalled as soon as you connect a network cable to the system the Auto Select Media Type function will detect the type of cable making the connection and automatically select that media type If you cha...

Page 23: ...computer and the EtherDisk diskette supplied with the adapter The configuration process is shown in Figure 3 1 Figure 3 1 Adapter Configuration Overview 1 2 Configure the adapter using the EISA config...

Page 24: ...ram as part of the adapter configuration process If your computer is running Windows 95 skip the next section and follow the instructions in the section Using Windows 95 If you are using a network ope...

Page 25: ...displayed instructions to save and exit the program Then proceed to Chapter 4 Loading Network Drivers Using Windows 95 If you are running Windows 95 after installing the adapter run the EISA configur...

Page 26: ...hlighted for more information about each of the settings When you run the EtherDisk diskette Configuration and Diagnostic Program to change software options make sure that network drivers or memory ma...

Page 27: ...ces under DOS in order to improve network throughput In multitasking environments choosing the Minimized CPU Utilization option saves the resources of the CPU for other tasks If no other applications...

Page 28: ...ot your computer under DOS version 3 1 or later 3 Place the EtherDisk diskette in a floppy drive on your computer and make that drive the active drive For example A Enter 4 Type at the prompt INSTALL...

Page 29: ...for information on AutoLink server support To manually set up your adapter or for information drivers for other NOSs use the options under Standard Installation and Configuration in the main menu Ethe...

Page 30: ...Port Address and Interrupt Level parameters are for information only To change them you must use the EISA configuration utility that came with your computer 12 Use the arrow keys to scroll through the...

Page 31: ...View Select F1 Help Test Configuration and Diagnostic Program C Copyright 1995 3Com Corporation All Rights Reserved ENTER Auto Configure Automatically Configures the Adapter Alt Highlighted Key Execu...

Page 32: ...x you can use 3Com s AutoLink auto installation feature which automatically loads all the NetWare DOS ODI client software including drivers Follow the instructions in the section Loading NetWare ODI D...

Page 33: ...C59X drivers are not backward compatible with the 3C5X9 family of EtherLink III adapters ISA EISA or MCA The latest version of the EtherDisk diskette is available on 3Com s Bulletin Board Service BBS...

Page 34: ...The software also modifies the CONFIG SYS and AUTOEXEC BAT files It automatically logs on to the server and updates the client software if your system administrator has already configured a 3Install a...

Page 35: ...use the AutoLink feature to install the NetWare DOS ODI driver your computer must meet the following requirements Use the Novell NetWare 2 x 3 1x or 4 x network operating system Have only one 3C592 E...

Page 36: ...pter a license screen appears To accept the terms and conditions of the 3Com end user software license agreement type the following Y To view the full text of the license agreement press F1 Once you h...

Page 37: ...menu for information on AutoLink server support To manually set up your adapter or for information drivers for other NOSs use the options under Standard Installation and Configuration in the main men...

Page 38: ...nk feature Multiple Adapters in a Client You can install multiple EISA adapters when you initially set up your EISA computer or you can add a second EISA adapter to a computer in which a single adapte...

Page 39: ...ration b Remove the EISA configuration diskette and exit the program c Restart the computer 6 Insert the EtherDisk diskette and run the AutoLink program Refer to the sections AutoLink Requirements and...

Page 40: ...y be different Each frame type must be different as shown in the previous examples Refer to Novell s DOS ODI client manual for information on the frame types to use 14 Reboot the computer Finding the...

Page 41: ...single adapter in an EISA computer that is functioning as a server follow the instructions in this section to load the NetWare 4 x server driver The 3C59X EtherDisk diskette contains a NetWare 4 x ser...

Page 42: ...e port address multiply the slot number by 1000 hex If the adapter is installed in slot number three for example multiply 3 by 1000 hex 3000 hex When running the 3C59X LAN driver with NetWare 3 11 you...

Page 43: ...e a Boot the computer under DOS b Insert the EtherDisk diskette in a floppy drive and make that drive the active one c At the prompt type INSTALL Enter The main menu appears 2 Select Configuration Dia...

Page 44: ...PORT XXXX NAME X Enter LOAD C 3C59X LAN PORT XXXX NAME Y Enter BIND IPX TO X NET XXXX BIND IPX TO Y NET XXXX where XXXX is the adapter s port address and NAME X and Y are names that you assign to help...

Page 45: ...his option Driver from disk by hardware manufacturer 3 Click OK 4 You are prompted to insert the manufacturer s disk into the drive selected a Insert the EtherDisk diskette and click OK b In the panel...

Page 46: ...about working in other network operating systems Refer also to your network operating system manuals for additional information NDIS Drivers If you have loaded NDIS drivers in a computer with multiple...

Page 47: ...driver agents which provide network management capabilities for adapters and PCs are available with Transcend PC Link SmartAgent software or on 3Com s bulletin board service BBS For information on 3Co...

Page 48: ...MI allows any DMI compatible management application to access 3Com adapter information 3Com s SmartAgent driver agents can take full advantage of the Management Information File MIF that is included w...

Page 49: ...ocedures in this chapter might be used Make sure that the adapter is correctly installed See Chapter 2 for installation instructions Figure 5 1 Troubleshooting Overview 1 Access DOS 2 Start the diagno...

Page 50: ...r memory managers EMM386 EXE and HIMEM SYS installed To avoid loading the drivers or memory managers you can bypass the AUTOEXEC BAT and CONFIG SYS files If you are running under DOS 6 2 pressing F5 w...

Page 51: ...er DOS If you are running Windows 95 reboot the computer and press F4 when you see the message Starting Windows 95 b Insert the EtherDisk diskette in a floppy drive and make that drive the active one...

Page 52: ...ove through the Index listings Select Test Definitions and press Enter To run the Group 1 tests follow these steps 1 Under the Test pull down menu select Run Tests Press Enter The Run Tests dialog box...

Page 53: ...mittent failures Assembling a Loopback Plug If you do not have a loopback plug you may be able to get one from your authorized network supplier or you can make your own To assemble the loopback plug c...

Page 54: ...tive network on which only the computer being tested and the echo server are operating To run the Group 3 test on the network you need a second computer set up as an echo server The echo server receiv...

Page 55: ...set up as an echo server Starting the Group 3 Test To run the Group 3 test on a 3C592 EISA adapter follow these steps 1 Start the Configuration and Diagnostic Program This program must be on the compu...

Page 56: ...diagnostic tests fail the adapter may not be defective The problem may be incorrect option settings option settings that conflict with the settings of other adapters or improper installation Follow th...

Page 57: ...adapter boards installed in the computer If you need help select Configuration Diagnostic Troubleshooting on the 3C59X EtherDisk diskette main menu Then select Configuration and Diagnostic Program Wh...

Page 58: ...Test Setup button in the Run Tests dialog box 2 Press Tab to highlight any of the fields within the Test Setup dialog box 3 To change a setting in any field follow these steps a In the Group Select b...

Page 59: ...pport Link Beat LED The 3C592 EISA adapters have an LED for the link beat see Figure 1 1 The link beat LED confirms that there is an active connection between the adapter and the hub When you first in...

Page 60: ...dustry standard for a 10 Mbps baseband CSMA CD local area network 3C592 COMBO IEEE 802 3i 10BASE T and Ethernet IEEE 802 3 industry standard for a 10 Mbps CSMA CD local area network Physical Dimension...

Page 61: ...e A 1 lists the pin assignments for the AUI attachment unit interface connector 8 7 6 5 4 12345678 3 2 1 RD 6 RD 3 TD 2 TD 1 Table A 1 AUI Connector Pin Assignments Pin Function Pin Function 1 Collisi...

Page 62: ...authority to operate this equipment Examples of supported cable types are shown below For unshielded twisted pair UTP connections 100 ohm Level 3 LAN and high speed data cable for example Anixter CM 0...

Page 63: ...as technical articles This service is available via modem or ISDN seven days a week 24 hours a day Access by Modem To reach the service set your modem to 8 data bits no parity and 1 stop bit Call the...

Page 64: ...atches software drivers and technical articles about all 3Com products as well as an interactive forum for technical questions To use ThreeComForum you need a CompuServe account To use ThreeComForum 1...

Page 65: ...if applicable If you are outside the U S and Canada contact your local 3Com sales office to find your authorized service provider Country Fax Number Country Fax Number Australia 800 123853 Netherland...

Page 66: ...to the sender unopened at the sender s expense To obtain an RMA number call or fax Hong Kong 852 868 9111 United Arab Emirates 971 4 349049 Italy 39 2 273 02041 U K 44 1628 897000 Japan 81 3 33457251...

Page 67: ...so known as the transceiver cable The AUI cable is used to connect an external transceiver to a computing device AutoLink 3Com autoinstallation and autoconfiguration software for NetWare DOS clients I...

Page 68: ...or Coaxial cable An electrical wire consisting of two primary electrical elements an outer braided wire that acts as a ground and an inner one used to carry signals Configuration The software settings...

Page 69: ...od of placing data or packet signaling on a cable Access to the cable is based on CSMA CD carrier sense multiple access with collision detection ISA Industry Standard Architecture A 16 bit extension o...

Page 70: ...data packets simultaneously instead of sequentially For example when transmission is the task the Parallel Tasking architecture begins to write data to the network even before an entire frame has been...

Page 71: ...5 features 1 2 finding port address 4 12 inserting 2 2 installing drivers 4 1 introduction 1 1 multiple 3 8 4 7 4 11 5 3 troubleshooting 5 1 unpacking 2 2 address port 4 7 4 12 attachment unit interfa...

Page 72: ...aster adapter 1 1 configuration diskette 3 2 EL59X 386 driver 4 16 EL59X DOS driver 4 16 EL59X SYS driver 4 16 Encoder Decoder Loopback Test 5 4 end user software license agreement 4 5 EtherDisk diske...

Page 73: ...nts A 2 port address 4 11 4 12 4 13 power requirements A 1 PROTOCOL INI file 4 15 Q QINSTALL SERVER directory 4 4 R readme files 4 11 Register Access Test 5 4 returning products for repair B 4 reverse...

Page 74: ...4 INDEX W Windows 3 X 4 3 Windows 95 1 2 3 3 4 1 confirming adapter installation 2 4 driver loading 4 14 running diagnostic tests 5 3 Windows for Workgroups 4 16 Windows NT 4 16 Z Zoom 5 8...

Page 75: ...tions Customer assumes responsibility for the selection of the appropriate applications program and associated reference materials 3Com makes no warranty that its software products will work in combin...

Page 76: ...S OF ANY KIND OR FOR LOSS OF REVENUE LOSS OF BUSINESS OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE USE PERFORMANCE FAILURE OR INTERRUPTION OF ITS PROD...

Page 77: ...try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment int...

Page 78: ...al and light industry IEC 801 2 Electromagnetic compatibility for industrial process measurement and control equipment Part 2 Electrostatic discharge requirements Severity level 3 IEC 801 3 Electromag...

Reviews: