background image

 

Related Standards

 

The Hub 10 24 Port TP has been designed to conform to the following 

 

standards:

 

Physical

 

Electrical

 

Hub 10 24 Port TP only

 

Hub 10 24 Port TP & Management Module

 

Environmental

T

ECHNICAL

 I

NFORMATION

 

Functional

 

ISO 8802/3, IEEE 802.3

 

Safety

 

UL 1950, EN 60950, CSA 22.2 #950

 

EMC

 

EN 55022 Class B, EN 50082-1, FCC Part 15 Class A, 

 

CSA C108.8 Class A

 

(screened cables must be used to ensure 

 

compliancewith these standards)

 

Environmental

 

EN 60068 (IEC 68)

 

Width

 

440mm (17.3 ins)

 

Depth

 

224mm (8.8 ins)

 

Height

 

44mm (1.7 ins) or 1U

 

Weight

 

2.7kg (5.9lb)

 

Mounting

 

free standing, 

 

or 19" rack or wall mounted using kit supplied

 

Power Inlet

 

IEC 320

 

Fuse Protection

 

2 Amps

 

Power Consumption

 

28 VA

 

Power Dissipation

 

96 BTU/hr

 

Power Inlet

 

IEC 320

 

Fuse Protection

 

2 Amps

 

Power Consumption

 

36 VA

 

Power Dissipation

 

123 BTU/hr

 

Operating Temperature

 

0-50

 

°

 

C (32-122

 

°

 

F)

 

Humidity

 

0-90% (non-condensing)

SuperStack™ II Hub 10
24 Port TP (3C16671A)
User Guide

 

DUA1667-1AAA03

Summary of Contents for SuperStack II 3C16671A

Page 1: ...s must be used to ensure compliancewith these standards Environmental EN 60068 IEC 68 Width 440mm 17 3 ins Depth 224mm 8 8 ins Height 44mm 1 7 ins or 1U Weight 2 7kg 5 9lb Mounting free standing or 19...

Page 2: ...ne peut pas tre mise en marche des sources de courant IT Imp dance la terre Si vos sources de courant sont de type IT cette unit doit tre aliment e par 230V 2P T via un rapport de transformation d iso...

Page 3: ...all TP ports on the unit will be disabled during power up until they are correctly configured and enabled by management software This is only necessary on units which have ports assigned as standby St...

Page 4: ...dule port If this LED does not flash there are no packets being received by the unit 8 Collision LED The Collision LED flashes yellow when a packet collision has been detected on a segment connected t...

Page 5: ...units together Do not use two cables to connect any two units to each other they will not work if you do this Disconnect power from all units that will form part of the new stack Connect the male hub...

Page 6: ...tin Boards The upgrade includes instructions on how to load the agent Managing with an FMS Management Module Managing with a Hub 10 Management Module 3C16630A or a Hub 10 Advanced RMON Module 3C16632...

Page 7: ...river Repeat the last two steps for the other side of the units To wall mount the Hub 10 unit s Ensure that the wall you are going to use is smooth flat dry and sturdy Attach a piece of plywood 12 x 2...

Page 8: ...S MISUSE NEGLECT IMPROPER INSTALLATION OR TESTING UNAUTHORIZED ATTEMPTS TO REPAIR OR MODIFY OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE OR BY ACCIDENT FIRE LIGHTNING OR OTHER HAZARD Limit...

Reviews: