background image

 

Related Standards

 

The Hub 10 24 Port TP has been designed to conform to the following 

 

standards:

 

Physical

 

Electrical

 

Hub 10 24 Port TP only

 

Hub 10 24 Port TP & Management Module

 

Environmental

T

ECHNICAL

 I

NFORMATION

 

Functional

 

ISO 8802/3, IEEE 802.3

 

Safety

 

UL 1950, EN 60950, CSA 22.2 #950

 

EMC

 

EN 55022 Class B, EN 50082-1, FCC Part 15 Class A, 

 

CSA C108.8 Class A

 

(screened cables must be used to ensure 

 

compliancewith these standards)

 

Environmental

 

EN 60068 (IEC 68)

 

Width

 

440mm (17.3 ins)

 

Depth

 

224mm (8.8 ins)

 

Height

 

44mm (1.7 ins) or 1U

 

Weight

 

2.7kg (5.9lb)

 

Mounting

 

free standing, 

 

or 19" rack or wall mounted using kit supplied

 

Power Inlet

 

IEC 320

 

Fuse Protection

 

2 Amps

 

Power Consumption

 

28 VA

 

Power Dissipation

 

96 BTU/hr

 

Power Inlet

 

IEC 320

 

Fuse Protection

 

2 Amps

 

Power Consumption

 

36 VA

 

Power Dissipation

 

123 BTU/hr

 

Operating Temperature

 

0-50

 

°

 

C (32-122

 

°

 

F)

 

Humidity

 

0-90% (non-condensing)

SuperStack™ II Hub 10
24 Port TP (3C16671A)
User Guide

 

DUA1667-1AAA03

Summary of Contents for SUPERSTACK II HUB 10 24-PORT TP

Page 1: ...es must be used to ensure compliancewith these standards Environmental EN 60068 IEC 68 Width 440mm 17 3 ins Depth 224mm 8 8 ins Height 44mm 1 7 ins or 1U Weight 2 7kg 5 9lb Mounting free standing or 19 rack or wall mounted using kit supplied Power Inlet IEC 320 Fuse Protection 2 Amps Power Consumption 28 VA Power Dissipation 96 BTU hr Power Inlet IEC 320 Fuse Protection 2 Amps Power Consumption 36...

Page 2: ...e peut pas être mise en marche des sources de courant IT Impédance à la terre Si vos sources de courant sont de type IT cette unité doit être alimentée par 230V 2P T via un rapport de transformation d isolation de 1 1 avec un point de connexion secondaire étiqueté Neutre branché directement à la Terre à la Masse La Cordon d Alimentation Surmoulé Celui ci doit être approuvé pour le pays auquel il s...

Page 3: ... all TP ports on the unit will be disabled during power up until they are correctly configured and enabled by management software This is only necessary on units which have ports assigned as standby Standby ports in resilient link pairs can only be configured on SuperStack II Hub 10 or LinkBuilder FMS II units Security features are described in the manual which comes with your Hub 10 Management Mo...

Page 4: ... Module port If this LED does not flash there are no packets being received by the unit 8 Collision LED The Collision LED flashes yellow when a packet collision has been detected on a segment connected to one of the 24 twisted pair ports the AUI port or the Transceiver Module port Under normal 802 3 operation collisions occur and cause the Collision LED to flash The probability of collisions incre...

Page 5: ...ect units together Do not use two cables to connect any two units to each other they will not work if you do this Disconnect power from all units that will form part of the new stack Connect the male hub expansion connector of one unit to the female hub expansion connector of the next unit Repeat this process until all the units are connected together Refer to Stacking Units for the number of unit...

Page 6: ...etin Boards The upgrade includes instructions on how to load the agent Managing with an FMS Management Module Managing with a Hub 10 Management Module 3C16630A or a Hub 10 Advanced RMON Module 3C16632 If you have a Hub 10 LinkBuilder FMS or FMS II unit fitted with a Management Module and a LinkBuilder 10BTi in your stack the Hub 10 FMS or FMSII Management Module will manage the stack The LinkBuild...

Page 7: ...driver Repeat the last two steps for the other side of the units To wall mount the Hub 10 unit s Ensure that the wall you are going to use is smooth flat dry and sturdy Attach a piece of plywood 12 x 20 x 0 5 securely to the wall if necessary and mount the Hub 10 unit s as follows Position the unit s against the wall or plywood ensuring that the ventilation holes face sideways Mark on the wall the...

Page 8: ...N S MISUSE NEGLECT IMPROPER INSTALLATION OR TESTING UNAUTHORIZED ATTEMPTS TO REPAIR OR MODIFY OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE OR BY ACCIDENT FIRE LIGHTNING OR OTHER HAZARD Limitation of Liability TO THE FULL EXTENT ALLOWED BY LAW 3COM ALSO EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY WHETHER BASED IN CONTRACT OR TORT INCLUDING NEGLIGENCE FOR INCIDENTAL CONSEQUENTIAL ...

Reviews: