background image

Wearing your elastomeric 
full face, 6 strap respirator

Fully loosen all
six head straps.
Pull hair back
with one hand.
Bring facepiece
up to face with
other hand.

While holding
the facepiece in
place, pull the
straps over 
your head.

Tighten the two
bottom straps.

Tighten the two
middle straps,
then the two 
top straps.

Fitting Instructions for 3M

TM

Elastomeric

Full Face 6 Strap Respirator

10008

page 1 of 2

3

Issue Date 01/01/04

Check the seal of your elastomeric full face, 6 strap
respirator each time you don the respirator.

1.  Positive Pressure User Seal Check

Place the palm of your hand over the exhalation valve cover and

exhale

gently. The facepiece should bulge slightly. If air leaks

between the face and the faceseal of the respirator, reposition it and
adjust the straps for a tighter seal. If you cannot achieve a proper
seal, 

do not

enter the contaminated area. See your supervisor.

2.  Negative Pressure User Seal Check

Using Particulate Filters

Place your thumbs over the
center of the particulate filters
and 

inhale

gently. The facepiece

should collapse slightly. If air
leaks between the face and the
faceseal of the respirator,
reposition it and adjust the
straps for a tighter seal. If you
cannot achieve a proper seal, 

do not

enter the contaminated

area. See your supervisor.

Using Cartridges

Place the palms of your hands
over the cartridges and 

inhale

gently. The facepiece should
collapse slightly. If air leaks
between the face and the
faceseal of the respirator,
reposition it and adjust the
straps for a tighter seal. If you
cannot achieve a proper seal,

do not

enter the contaminated

area. See your supervisor.

1

2

3

4

Reviews: