background image

  

Operations and Instruction Manual 

Model #4075 

Portable Concrete Anchorage Connector 

ANSI Z359.1-07  5,000 lbs / 22kn 

OHSA 1910.66 & 1926.502

 

Effective: 01/2012   Expires: 01/2022   IM-0049 REVA 

1. 

Follow all manufacturer’s instructions. 

2. 

Do not use incompatible connectors. 

3. 

Always inspect your units prior to use. 

4. 

Use the proper method of coupling to anchorage. 

5. 

Remove unit for service if a fall has occurred.  

6. 

Patch all holes with concrete when job is complete. 

7. 

For use by one person only. 

8. 

Pregnant women and minors must not use this product. 

9. 

Designed safe working load is 400 LBS (149.3 kg). Do not  

        exceed this weight. 
10.   Not for use with horizontal lifeline systems.  Refer to item #4077.

 

Model #4075 SafeClaw 3/4” anchor is to be used in concrete substrate only.  

DO NOT use in steel, wood or any other substrate.   

 

This product is designed for use in cured concrete only and may be pulled in all directions up to 90. 

 

SafeClaw Fall Protection Anchor can be placed in: 

 

* Horizontal surfaces 

* Vertical surfaces 

* Overhead / ceiling surfaces 

*** Warning *** 

Do not use incompatible connectors with any SafeClaw Anchor.  

Refer to separate instructions supplied with your anchorage connector. 

Spoon 

End Termination 

Bushing Guide 

Stop Sleeve 

Trigger 

Spring Swage 

Anchor Loop 

Heavy Duty Return Wire 

3/4” SafeClaw Anchorage Connectors 

3/4” SafeClaw

 

 Fall Protection Anchor 

 



Model  -  #4075 



Designed safe working load: 400 lbs. 



Tested  -  ANSI Z359.1-2007 



OSHA  -  1910.66 & 1926.502 



Strength  -  5,000 lbs / 22kn 



Color coded in orange tubing 

IMPORTANT 

All persons using this equipment must read and understand all instructions. Failure to do so may result in serious injury or 
death. If a fall occurs, the SafeClaw anchor must be disposed of according to the manufacturer instruction. Users should be 

familiar with pertinent regulations governing this equipment. All individuals who use this product must be correctly 

instructed on how to use this device.  

Summary of Contents for 4075

Page 1: ...d concrete only and may be pulled in all directions up to 90 SafeClaw Fall Protection Anchor can be placed in Horizontal surfaces Vertical surfaces Overhead ceiling surfaces Warning Do not use incompatible connectors with any SafeClaw Anchor Refer to separate instructions supplied with your anchorage connector Spoon End Termination Bushing Guide Stop Sleeve Trigger Spring Swage Anchor Loop Heavy D...

Page 2: ...must meet the 5 000 lb requirement All personal fall arrest systems must meet all applicable state federal city OSHA and ANSI requirements and any other regulating government body It is the responsibility of the employer to regulate its worker and make sure all laws are being complied with concerning this device This anchorage point attachment must be identified by a qualified or competent person ...

Page 3: ...eration distances from shock absorbers and make sure you obtain a minimum 2 clearance Swing fall can occur when the worker is not directly under the anchorage point Avoid a swing fall by working directly underneath your anchorage point Swing falls can jeopardize the clearance required with retractable shock absorbing lanyards and other sub systems of your fall protection system Avoid swing fall at...

Page 4: ... inspect your units prior to use Use the proper method of coupling to anchorage Remove unit from service if a fall has occurred Patch all holes with concrete when job is complete For use by Single User only Pregnant women and minors must not use this product Designed safe working load is 400 LBS 181 kg Do not exceed this weight Important Warnings This product is to be used by trained fall protecti...

Page 5: ...4 in diameter and drilled at least 3 into the substrate The bored hole walls must be straight and parallel NOTE The bored hole must be of uniform diameter and free of peaks and valleys on the inner wall surfaces Only use quality industrial grade rotary hammers and rotary hammer drill bits NEVER USE A BENT DRILL BIT Drill a straight 3 4 diameter hole at least 3 deep into your substrate utilizing a ...

Page 6: ... your other hand pinch the two spoons between your thumb and index finger Hold the trigger fully retracted while inserting the unit into bottom of the hole Company Logo Hole Diameter Size Manufactured Date Batch Number Model Number ANSI Z359 1 Mark Warning Instructions Compliance ANSI Z359 1 07 5 000 lbs OSHA 1910 66 1926 502 Model 4075 Batch 000 Manufactured 00 00 00 US Patent 6 729 821 US Patent...

Page 7: ...ATE OF MANUFACTURE _________________________________________________ MODEL NUMBER _________________________________________________________ 3M Occupational Health Environmental Safety Division 3M Center Building 235 2W 70 Saint Paul MN 55144 1000 USA Technical Assistance 1 800 243 4630 in U S and 1 800 267 4414 in Canada www 3M com FallProtection www 3M com PPESafety ...

Reviews: