infinias eIDC

32

 | QUICK START GUIDE

eIDC Quick Start Guide.book  Page 1  Monday, May 11, 2009  11:41 AM

Summary of Contents for infinias eIDC32

Page 1: ...infinias eIDC32 QUICK START GUIDE...

Page 2: ......

Page 3: ...been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not opera...

Page 4: ...led near the equipment and shall be easily accessible Supplementary Instructions Only use replacement parts recommended by infinias The product and or manual may bear the following marks This symbol i...

Page 5: ...pages for configuring and using the device This allows an eIDC to be used as a stand alone unit for a single door that is the eIDC web software can be used to manage view and report activity through...

Page 6: ...nd 4 do not add an additional power supply to terminals PWI or PWI refer to Figure 2 on the eIDC UPS Power Option PoE CAT 5 6 Power Option PoE CAT 5 6 non PoE CAT 5 6 Power Option UPS Power Option non...

Page 7: ...Cat 6 from the Midspan PoE Injector to the eIDC Ethernet connector 4 Go to Determine the eIDC IP Address on page 8 and complete the installation NON PoE SWITCH 1 Using non PoE run a standard network c...

Page 8: ...ent on the data network and requires an IP address The eIDC network connection is either for static addressing or Dynamic Host Configuration Protocol DHCP addressing Use of a DHCP permanently leased I...

Page 9: ...rs when power is connected to the eIDC the network IP address type is static 1 All of the LEDs flash continuously more than three times for approximately 10 seconds This means a DHCP IP address cannot...

Page 10: ...he user name and password text boxes admin is the default value for both of these fields NOTE Iftheusernameandpasswordhavebeenareunknown youwill need to reset the eIDC to its factory default settings...

Page 11: ...PCON Power Connector Ethernet Connection Output 1 Output 2 Input 1 Input 2 Common Card Reader IN Power Output 1 24V DC IN Optional External Power Supply 24 vDC 1 Amp Output 3 NC Output 3 NO Common Inp...

Page 12: ...open and NC normally closed and powered externally Relay Output 3 has separate terminals for common C normally open NO and normally closed NC but the software designation must match for proper status...

Page 13: ...IDC is to be used as a stand alone unit for a single door then go to the eIDC Web Server Single Door Application section on page 14 If the eIDC is to be used with infinias Access then refer to the inf...

Page 14: ...tem button to display the System Management screen 6 Click the Database Management button 7 Click the Load Default Configuration button Click OK to close any dialog boxes that appear 8 After the devic...

Page 15: ...t 2017 3xLOGIC Inc All rights reserved QSG 002 01 03 2017 This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002 96 EC of the European...

Page 16: ...3xLOGIC Inc Headquarters 10385 Westmoor Drive Ste 210 Westminster CO 80021 USA Direct Tel 303 430 1969 Toll Free in USA 877 395 6442 www 3xlogic com QSG 002...