background image

4-noks SRL - Via Per Sacile, 158 - Francenigo di Gaiarine (TV) - Italy

Tel. +39 0434 768462 - Fax +39 0438 694617 - info@4-noks.com - www.4-noks.com

Quick

Guide

+05T408021R1.2 – E4U - E4U-S Quick Guide - EN - 05/03/2015

ELIOS4YOU &

ELIOS4YOU

SMART

ID CODE:YYYYY

123456789XXXXX

ID CODE:YYYYY

123456789XXXXX

L

N

The Elios4you family of products are wireless devices designed to monitor and manage 
single-phase photovolatic installations via the Elios4you APP. Maximum monitored power 
10kW. The transmitter measures the energy generated of the PV plant, exchanged with 
the grid, the household consumption and the self-consumption. In the “Smart” version 
it allows to optimize the self-consumption by turning programmed loads with additional 
Plug and Switch accessories.

EN

Elios4you

Current

transformers pair

ID Code label

READ AND KEEP THESE INSTRUCTIONS FOR REFERENCE

All models are compliant to 
directive 2004/108 CE - 2006/95
CE - directive 99/5 CEE

The appliance (or the product) 
must be disposed of separately 
in accordance with the local 
regulations regarding disposal.

Product identification

this document refers to following devices:

Code

E4U 

Elios4you

E4U-S 

Elios4you

Smart

Elios4you 

Smart

L

N

L

N

L

N

K

L

K

L

INSTALLATION SCHEMATIC

Generation CT 

(white label)

Generation CT 

(white label)

Main Meter

PHOTOVOLTAIC PLANT INTO THE MAIN CIRCUIT BREAKER

13 14 15 16 17 18 19 20 21 22 23 24 

N  L  3  4  5  6  7  8  9 10 11 12 

13 14 15 16 17 18 19 20 21 22 23 24 

N  L  3  4  5  6  7  8  9 10 11 12 

SIG + Generation CT - Red color

SIG + Generation CT - Red color

Alarm 2 -NO

Alarm 2 -NO

Alarm 1 -NO

Alarm 1 -NO

X

Shield = optional Main CT

Shield = optional Main CT

Relay 
normally 
open

Relay 
normally 
open

Load

Load

Common relay

Common relay

Hole for CONFIG 

button

Hole for CONFIG 

button

ID Code label

ID Code label

ATTENTION:

 Installation must be completed by 

qualified personnel only. The customer (builder, 
developer or installer ) accepts all liability and 
risk relating to the configuration of the product 
to achieve the expected results in relation to the 
specific installation. Any deficiencies in the ac-
knowledgment of the instructions may lead to 
malfunctions and / or damage to the devices, 
to which 4-NOKS cannot be held responsible. 
The responsibility of 4-NOKS in relation to the 
devices manufactured is regulated by the gen-
eral terms & conditions. Be careful to ensure all 
works being carried out are completed by quali-
fied personnel, during which, no power is being 
supplied to the devices.

Main CT

(yellow label)

Main CT

(yellow label)

IN+10 V

Ctrl

GND

SIG - Main CT - Black color

SIG - Main CT - Black color

SIG + Main CT - Red color

SIG + Main CT - Red color

SIG - Generation CT - Black color

SIG - Generation CT - Black color

Shield = optional Generation CT

Shield = optional Generation CT

L

N

L

N

K

L

1A

Generation

meter

Main Meter

PHOTOVOLTAIC PLANT DIRECTLY WIRED INTO THE MAINS METER

Fig.1

Fig.2

X X

X X X X

X

IN+10 V

Ctrl

GND

X X

X X X X

Generation

meter

Green point and the direction 
of the arrow K 

 L towards 

the main circuit breaker

Green point and the direction 
of the arrow K 

 L towards 

the main circuit breaker

ID CODE:YYYYY

123456789XXXXX

ID CODE:YYYYY

123456789XXXXX

Main 

Circuit Breaker

Main 

Circuit Breaker

1A

K

L

ATTENTION

Reviews: