Page 1: ...EAP706 Enterprise Access Point ...

Page 2: ... not copy reproduce distribute publish display perform or modify any part of this publication in any form or by any means without prior written permission from 4IPNET INC You may not alter or remove any copyright or other notice from copies of the content All other brand and product names are claimed or registered marks of their respective companies or organizations All rights reserved To download...

Page 3: ... the receiver is connected Consult the dealer or an experienced radio TV technician for help Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and ...

Page 4: ... Caution This declaration is only valid for configurations combinations of software firmware and hardware provided and supported by 4ipnet Inc The use of software or firmware not provided and supported by 4ipnet Inc may result in the equipment no longer being compliant with the regulatory requirements European standards dictate maximum radiated transmit power of 100mW EIRP and frequency range 2 40...

Page 5: ...urity 802 1X WPA and WPA2 and multiple ESSIDs with VLAN tags to separate the traffics of different departments A centralized WLAN management allows enterprises and organizations to support a wide array of value added applications such as load balancing bandwidth control and access control The patent pending 4ipWES Press n Connect technology bridges multiple EAP706s at the touch of a button which e...

Page 6: ...hernet cables here to connect to the wired local network 2 Bypass RJ 45 pass through port 3 DC Jack 12V 1 A Attach the power adaptor here 1 Restart Reset Button Press once to restart the system Press and hold for more than 5 seconds to reset to factory default 2 LED Indicators 4 LED lights Representation is listed at the top of the panel 3 WES Button WDS Easy Setup Press the button to build up a W...

Page 7: ...down Block Pass through Copper wire punch down for wiring bypass 3 110 Punchdown Block Uplink PoE Copper wire punch down for Uplink connection This can be used to connect to a controller gateway or directly to the internet PoE is supported 4a SMA Connectors 2 4GHz Connect external antennas for RF Card A here 1 is the primary antenna connector while 2 is the secondary connector 4b SMA Connectors 5G...

Page 8: ...re of EAP706 Step 1 Place the EAP706 at the best location The best location is usually at the center of your intended wireless network The EAP706 can be mounted on any wall outlets or on any flat surface Universal Mounting Panel Secure the mounting plate on the mounting surface by tightening the screws included at the highlighted area below a Standard US Outlet box b Standard EU Outlet box ...

Page 9: ...reen White Brown White Green The EAP706 is now connected to your existing wired LAN network Step 3 There are three ways to supply power to EAP706 a Connect the DC power adaptor to the power jack socket b The Uplink port is capable of receiving PoE Connect an IEEE 802 3af compliant PSE device e g a PoE switch to the Uplink port of EAP706 with the Ethernet cable c Use a standard 110 punchdown tool t...

Page 10: ... the tool provided and turn clockwise Now the Hardware Installation is complete Punch down tools may vary by country Please contact the 4ipnet Support Team for recommendations if needed Please use only the power adapter supplied with the package Using a different power adapter may damage this system To verify the wired connection between the AP and your switch router hub please also check the LED ...

Page 11: ...255 255 255 0 Steps 1 To access the Web Management Interface connect the administrator PC to the LAN port of EAP706 via an Ethernet cable Then set a static IP address on the same subnet mask as EAP706 in TCP IP of your PC such as the following example IP Address 192 168 1 100 Subnet Mask 255 255 255 0 2 Launch the web browser on your PC by entering the IP address of EAP706 http 192 168 1 1 at the ...

Page 12: ... EAP706 a System Overview page of the Web Management Interface will appear as depicted below The Radio Status and AP Status will be shown The Web Management Interface System Overview Page 5 To logout simply click on the Logout button at the upper right corner of the interface to return to the Administrator Login Page Click OK to logout ...

Page 13: ...erved 9 Common Settings Step 1 Change Administrator s Password Change Password Page Click on the Utilities icon on the main menu and select the Change Password tab Enter a new password with a length of up to 32 characters and retype it in the Re enter New Password field Click SAVE to save the changes ...

Page 14: ...and Protocol and Channel for you wireless connection For example select 2 4GHz for the band 802 11g 802 11n for the protocol and 6 for the channel Note Admin should be aware of Dynamic Frequency Selection DFS mandated on some channels of the 5GHz band When an EAP705 detects interference this mechanism will limit the ability to broadcast the SSID on one of the channels listed below 1 Country Code 8...

Page 15: ...shown The EAP705 supports up to 8 virtual APs VAPs per radio Configure VAP profile settings a Select the VAP Config tab to configure the settings of the desired VAP b Enable a selected VAP from the drop down menu of Profile Name and configure related settings below Check VAP status After finishing VAP configuration the status of the enabled Virtual APs shall be reflected on the VAP Overview page ...

Page 16: ...Quick Installation Guide EAP706 Enterprise Access Point ENGLISH Copyright 4IPNET INC All rights reserved 12 Virtual AP Overview Page ...

Page 17: ...e Repeater tab Choose WDS as the Repeater Type Choose the desired RF for WES optional Choose the desired WDS profile a Enable WDS b Enter the Remote AP MAC Address peer AP and then Click SAVE If you are using another EAP705 as the peer AP simply repeat the above mentioned steps to configure another peer AP s Note On each and every configuration page you may click SAVE to save the changes of your c...

Page 18: ...EAP706 s network configuration is completed please remember to change the IP Address of your PC Connection Properties back to its original settings in order to ensure that your PC functions properly in its real network environments It is strongly recommended to back up your configuration settings For further configuration and information please refer to the User s Manual P N V10020160331 ...