background image

Maximum projected area of the floodlight:

12W: 0.024m

2

24W: 0.037m

2

48W: 0,083m

2

72W: 0.083m

2

120W: 0.136m

150W: 0,136m

2

200W: 0.136m

2

Dimension of Tempered Glass:

12W:  165x128x4 (mm)
24W:  213x163x4 (mm)
48W DLS: 320x242x4 (mm)
72W:  320x242x4 (mm)
120W: 390x332x5 (mm)
150W: 390x332x5 (mm)
200W: 390x332x5 (mm)

*aFlood LED Tec Symmetric DLS model
When the light level drops below 25 lux, the floodlight automatically 
turns on, turning off again when the light level rises about 75 lux.

Mounting Instructions 

Floodlight aFlood tec

Dimensions

Unit: mm

Mounting

Step 1: Open the packaging and examine the fixture. If the fixture  
 

is damaged, please contact the distributor.

Step 2: Mount the fixture's bracket to a wall or clamp.

Step 3: Adjust the fixture's position and angle the light in the  
 

desired direction before tightening the screws on the side  

 

of the fixture.

Step 4: Make sure the cables are connected correctly.  
 

Brown - Line Blue - Neutral Yellow/Green - Earth

Safety Message:

•  Electrical installations should only be carried out by a licensed electrician.
•  Switch off the power to the fixture and wait until it has cooled down before disassembling.
•  In the event of faults, the power to the fixture must be switched off immediately.  
  Do not attempt to repair the fixture yourself.  
  Contact your Ahlsell retailer to replace the fixture.
•  The mininum distance from lighted objects  
  to luminaries shall be kept at least 0.3m

Output

H1

H2

L1

L2

T

D1

D2

W1

W2

R

Ø

12W

175

205

135

150

42

31

8

20

8.5

4.25

8.5

24W

220

251

170

200

45

35

9

30

10.5

5.25

10.5

48W

290

330

225

243

55

40

9

35

11

5.5

12.5

48W DLS

330

372

250

265

75

40

9

40

11

5.5

12.5

72W

330

372

250

265

75

40

9

40

11

5.5

12.5

120W

400

450

340

360

90

55

20

55

13

6.5

13

150W

400

450

340

360

90

55

20

55

13

6,5

13

200W

400

450

340

360

90

55

20

55

13

6.5

13

ENGLISH

Summary of Contents for aFlood tec

Page 1: ...ning the screws on the side of the fixture Step 4 Make sure the cables are connected correctly Brown Line Blue NeutralYellow Green Earth Safety Message Electrical installations should only be carried out by a licensed electrician Switch off the power to the fixture and wait until it has cooled down before disassembling In the event of faults the power to the fixture must be switched off immediatel...

Page 2: ...ills den har svalnat innan demontering Vid fel ska spänningen till armaturen brytas omedelbart Försök inte reparera armaturen själv Kontakta din Ahlsellbutik för utbyte av armaturen Det minsta tillåtna avståndet mellan belysta föremål och ljuskällan ska vara minst 0 3m SVENSKA Maximal belyst yta 12W 0 024m2 24W 0 037m2 48W 0 083m2 72W 0 083m2 120W 0 136m2 150W 0 136m2 200W 0 136m2 Mått härdat glas...

Page 3: ... avkjølt før demontering Ved feil må du umiddelbart bryte spenningen til armaturen Du må ikke forsøke å reparere armaturen selv Kontakt din nærmeste Ahlsellbutikk for bytte av armatur Minimumsavstanden fra belyste objekter til armaturen er 0 3 m NORSK Lyskasterens maksimale projiserte areal 12W 0 024m2 24W 0 037m2 48W 0 083m2 72W 0 083m2 120W 0 136m2 150W 0 136m2 200W 0 136m2 Mål på herdet glass 1...

Page 4: ...n jäähtynyt ennen irrottamista Toimintahäiriön sattuessa valaisimenjännite on kytkettävä pois välittömästi Älä yritä korjata valaisinta itse Ota yhteyttä Ahlsellin jälleenmyyjään valaisimen vaihtamiseksi Valaistavien kohteiden on oltava vähintään 0 3 m etäisyydellä valaisimista SUOMI Valonheittimen heijastusalue korkeintaan 12W 0 024m2 24W 0 037m2 48W 0 083m2 72W 0 083m2 120W 0 136m2 150W 0 136m2 ...

Reviews: