User manual
HVC-PU 100-150 kW Overnight
©
Copyright ABB. All rights reserved
Page 1: ...User manual HVC PU 100 150 kW Overnight Copyright ABB All rights reserved...
Page 2: ...Copyright All rights to copyrights registered trademarks and trademarks reside with their respective owners Copyright ABB EV Infrastructure All rights reserved 2 6AGA000007 0604 EN 001...
Page 3: ...ation agreements 9 2 Description 10 2 1 Type plate 10 2 2 Intended use 10 2 3 Overview 11 2 3 1 Overview of the system 11 2 3 2 Power cabinet outside 12 2 3 3 Power supply box outside 13 2 3 4 Control...
Page 4: ...shooting 25 5 1 Troubleshooting procedure 25 6 Technical data 26 6 1 EVSE type 26 6 2 Cleaning specifications 26 6 3 Cleaning specifications contact dome 26 6 4 Compensation of the park tolerances 27...
Page 5: ...lustrations It is not always possible to show the configuration of your EVSE The illustrations in this document show a typical setup They are for instruction and description only 1 6 Units of measurem...
Page 6: ...ion about the condition of the EVSE before you start the procedure Requirements for personnel for a proce dure General safety instructions for a proce dure Information about spare parts that are neces...
Page 7: ...nt name Target group Product data sheet All target groups Installation manual Qualified installation engineer User manual Owner Service manual Qualified service engineer Declaration of conformity CE A...
Page 8: ...g center of the manufacturer Facility of the manufacturer to do a remote check on the correct operation of the EVSE Cabinet Enclosure of the EVSE including the components on the inside CHAdeMO Japanes...
Page 9: ...EVSE to charge the EV Note It is possible that not all terms are present in this document 1 15 Orientation agreements D C B X Z Y A A Front side face forward to the EVSE during normal use B Left side...
Page 10: ...f the EVSE L QR code with the contact information of the manufacturer M Additional EVSE rating data M Production date Note The data in the illustration are only an example Find the type plate on your...
Page 11: ...ction AC input cable To supply the electricity from the power distrubution board to the EVSE Auxiliary AC input cable To supply the electricity from the auxiliary power dis trubution board to the EVSE...
Page 12: ...m part of the EVSE Air inlet and outlet To let the cooling air in and out The airflow prevents overheating of the parts on the inside of the EVSE Type plate To show the identification data of the powe...
Page 13: ...rt Function Enclosure To reduce the accessibility of unqualified persons to the inside of the EVSE Door To prevent unauthorized access to the inside of the box Cable glands Openings for the cables Typ...
Page 14: ...ure To reduce the accessibility of unqualified persons to the inside of the EVSE Door To prevent unauthorized access to the inside of the EVSE Beacon To indicate the state of the EVSE Type plate To sh...
Page 15: ...acon with integrated LED indicator The beacon shows the status of the EVSE Table 1 Indications of the lights LED color LED status Status of the EVSE Error Idle Preparation phase Charging Charge comple...
Page 16: ...power in case of emergency Note The placement of this button is customized for every configuration 2 5 Options 2 5 1 Stop button A A Stop button The stop button is used to stop the charge session Not...
Page 17: ...urity breaches unauthorized access interference intrusion leakage and or theft of data or information The manufacturer is not liable for damages and or losses related to such security breaches any una...
Page 18: ...igh voltage and high current electrical installations Make sure that there is sufficient space around the EVSE to safely do maintenance and installation work Identify a site operator who is responsibl...
Page 19: ...Preliminary requirements Make sure that the EVSE is connected to an earthed metal permanent electrical system Alternatively install an equipment earthing conductor with circuit conductors Connect this...
Page 20: ...wner s sole responsibility to provide and continuously ensure a secure connection between the product and Owner s network or any other network as the case may be The Owner shall establish and maintain...
Page 21: ...ove the EVSE 5 Make sure that the space around the EVSE cannot get blocked Think of snow or other objects Refer to the space requirements in section 6 7 6 Make sure that maintenance is done on the EVS...
Page 22: ...EVSE shows the progress on the beacon 4 4 3 Stop a charge session 1 Push the stop button or obey the instructions of the EV Note The charge session stops automatically when the battery is full or the...
Page 23: ...ssary apply wax on the front for extra protection and gloss 6 If there was rust and you want it not to appear again apply a rust preventive primer Ask the manufacturer for specifications and instructi...
Page 24: ...the contact rails from hard ice crusts 6 If there was rust and you want it not to appear again apply a rust preventive primer Ask the manufacturer for specifications and instructions 4 5 4 Do a check...
Page 25: ...procedure 1 Try to find a solution for the problem with the aid of the information in this document 2 If you cannot find a solution for the problem contact the manufacturer Refer to section 1 12 Trou...
Page 26: ...PU 150 Overnight Brand HVC Type PU Power rating 150 kW Type of charging Overnight 6 2 Cleaning specifications Parameter Specification Cleaning agent pH value between 6 and 8 Non abrasive tool Non wov...
Page 27: ...le X1 Compensation on the X axis Y1 Compensation on the Y axis Z1 Maximum height of the EV with the pantograph Parameter Specification D 2 E 2 F 2 G 2 X1 1000 mm Y1 500 mm Z1 4500 mm 6 5 Bulk charge s...
Page 28: ...r Specification mm Width X dimension 600 Depth Y dimension 250 Height Z dimension 450 6 6 3 Power supply box Parameter Specification mm Width X dimension 600 Depth Y dimension 210 Height Z dimension 4...
Page 29: ...uired for air inlet on the side Y1 Total depth Y2 Space to open the power cabinet door Y3 Space for air outlet Setting with power cabinets side by side Parameter Specification mm X1 1000 n x 1170 wher...
Page 30: ...box X1 Space required on the sides Y1 Space to open the control box door Z1 Space required over the control box Z2 Space required under the control box Parameter Specification mm X1 100 Y1 900 Z1 600...
Page 31: ...quired under the power supply box Parameter Specification mm X1 500 Y1 900 Z1 600 Z2 600 6 8 Ambient conditions 6 8 1 Control box Parameter Value Ingression protection IP65 Operating temperature 35 C...
Page 32: ...ature 10 C to 70 C Maximum allowed pressure decrease 300 Pa Storage conditions Indoor dry Relative humidity 5 95 non condensing Airflow 1450 m3 h Altitude Max 2000 m above sea level 6 9 DC output spec...
Page 33: ...Technical data 6AGA000007 0604 EN 001 33...
Page 34: ......