background image

 

 

 

 

ABB AB / Jokab Safety

 Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden 

www.abb.com/jokabsafety 

Original instructions 

Sense7-series 

Non-contact coded safety switch 

 

 

Summary of Contents for Sense7 Series

Page 1: ...ABB AB Jokab Safety Varlabergsv gen 11 SE 434 39 Kungsbacka Sweden www abb com jokabsafety Original instructions Sense7 series Non contact coded safety switch...

Page 2: ...AFETY will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete dete...

Page 3: ...l description 5 Safety regulations 5 Function description 5 3 Connections 6 Connection 6 Cable configurations 6 Pin configurations 6 4 Installation and maintenance 7 Installation and maintenance 7 Mai...

Page 4: ...nstallation personnel Prerequisites It is assumed that the reader of this document has knowledge of the following Basic knowledge of ABB Jokab Safety products Knowledge of safety devices and safety lo...

Page 5: ...application must be considered In case of failure to comply with the instructions or standards especially when tampering with and or modifying the product any liability is excluded Function descriptio...

Page 6: ...rcuits are closed when the guard is closed and the actuator present Cable configurations ACTUATOR RECEIVER 1 RECEIVER 2 POWER RED 24VDC BLUE 0VDC BLACK IN WHITE OUT YELLOW IN GREEN OUT ORANGE IN BROWN...

Page 7: ...switch and the LED s on the safety relay are illuminated when the switch is closed and are extinguished when the switch is open 5 Check that the machine stops and cannot be re started when each switch...

Page 8: ...ody The minimum safety distance is calculated according to the formula S K x T C Where S minimum safety distance mm K approach speed of a human body 1600 mm s T the total time from opening of the guar...

Page 9: ...2TLC172249M0201 rev B 9 www abb com jokabsafety 2013 04 10 5 Application examples Application example...

Page 10: ...2TLC172249M0201 rev B 10 www abb com jokabsafety 2013 04 10...

Page 11: ...1NO LED Sense7Z 2TLA050056R4120 2 m cable 2NC 1NO LED Stainless Steel Sense7Z 2TLA050056R5120 5 m cable 2NC 1NO LED Stainless Steel Sense7Z 2TLA050056R6120 10 m cable 2NC 1NO LED Stainless Steel Sense...

Page 12: ...6 operations at 100mA load Recommended setting gap 5 mm Switching Distance target to target Sao 10 mm close on Sar 20 mm open off Tolerance to misalignment 5 mm in any direction from 5 mm setting gap...

Page 13: ...47 5 3 1999 A1 2005 EN ISO 13849 1 Up to PL e cat 4 depending on system architecture EN 62061 Up to SIL3 depending on system architecture Safety data PFHD B10d Proof test interval life MTTFd 2 52 x 10...

Page 14: ...2TLC172249M0201 rev B 14 www abb com jokabsafety 2013 04 10 8 EC Declaration of conformity ABB AB JOKAB SAFETY Varlabergsv gen 11 SE 434 39 Kungsbacka Sweden www abb com jokabsafety...

Page 15: ...1R0017 GJL1213001R0101 GJL1311001R0101 GJL1311001R8010 GJL1311201R0001 GJL1313001R0011 GJL1313001R0101 GJL1317201R0001 A40 30 10 84 AF09 30 01 11 AF460 30 11 68 1455 B14 250 EF45 30 ERG297 HSC2 20 1SA...