1
USER’S MANUAL
800L/2200L
This manual contains important safety instructions. Please follow all instructions during installation. Read this manual thoroughly before unpacking,
installing or operating.
Caution: Risk of Electric Shock
The UPS contains batteries. The output outlets may be electrically live even when the UPS is disconnected from the AC mains.
The UPS contains potentially hazardous voltages. Do not open the units as there are no user serviceable parts. All maintenance and servicing
should be performed by qualified service personnel.
Risk of electric shock, Battery Circuit is not isolated from AC input, hazardous voltage may exist between battery terminals and ground. Test
before servicing and use insulated tools.
NOTE:
The UPS is designed to be for use with computer loads only.
Caution
:
Do not connect a laser printer to the UPS.
A laser printer draws significantly more power than other types of equipment and may overload the UPS.
SETUP
1
Inspection
Inspect the UPS upon receipt.
Notify the carrier and dealer if there
is damage. The package is
recyclable; save it for reuse or
dispose of it properly.
Inspect accessories:
①
Power cable 1PCS
USER MANUAL 1PCS
2
Choose an installation location
- Avoid locations that are excessively humid, near water,
near heat sources or in direct sunlight
- Allow 1inch (2.5cm) clearance on each side of the UPS.
3
Connecting Equipment and Power to the UPS
4
Connect Modem/ Phone / Network for Surge Protection (Optional)
5
Connect Interface Device
6
Turn ON/OFF the UPS
Turn on the UPS: Press the UPS
On/OFF Switch for approx. 3
seconds, then the Buzzer sounds
twice, the UPS will start-up.
Turn off the UPS: Press the UPS
On/OFF Switch for approx. 3
seconds, then the Buzzer sounds
twice, the UPS will shutdown.
7
Cold Start Function
When the UPS is OFF and no utility input
power is present, use the “Cold Start”
feature to apply power to the loads from
UPS‘s battery. Press the “ON/OFF” switch
until the UPS beeps.
8
Software Download and Installation
Please follow steps below to download and install monitoring software:
1. Go to the website http://www.ablerex.com.sg/downloads.html
2. Depending on the computer OS, select Emily software (for Win 7&8 OS, select Emily2) and click download.
3. Follow the on-screen instructions to install the software.
4. When the computer restarts, the monitoring software automatically search and connects to the UPS.
FRONT PANEL EXPLANATIONS
800L / 1000L
–LED FRONT
PANEL (STANDARD)
Symbol
LED Color
Description/function
1500L/1800L/2200L
– LED
FRONT PANEL (STANDARD)
Symbol
LED Color
Description/function
N/A
Turn-on/Turn-off Switch
N/A
Turn-on/Turn-off Switch
Green
Lit: Line mode
Flashing: Battery mode
Green
Lit: Line mode
Dim: Abnormal input
voltage and frequency
Red
Lit: System malfunction
or abnormal
N/A
Load
Yellow
Lit: Battery mode
Flashing: Battery Low
N/A
Battery
Green
Load Percentage/
Battery Capacity
Red
Lit: System malfunction
or abnormal
REAR PANEL EXPLANATIONS
800L/1000L REAR PANEL
1. AC Input Outlet
2. Fuse
3. Output Connector:
4x IEC Outlets or
3x Universal Outlets or
1x Schuko Outlet or
4x Thailand Outlets
4. USB (Standard) or
RS232 (Optional)
5. Modem/Network
Surge protection
(Optional)
1500L/1800L/2200L REAR PANEL
1. AC Input Outlet
2. Fuse
3. Output Connector:
6x IEC Outlets or
or 4x Universal Outlets
or 2x Schuko Outlets
or 6x Thailand Outlets
4. USB (Standard) or
RS232 (Optional)
5. Modem/Network
Surge Protection (Optional)
6. Fan
Step1: Connect the UPS to the
AC mains.
Step2: Connect the equipment
to the UPS output outlets.
Step3: Switch on the AC Mains,
follow by the UPS then the
equipment last.
*Plug the UPS into the AC Mains
to charge for 8 hours before
using the UPS.
- For modem/phone line protection,
connect equipment to the RJ11
port using RJ11 cable.
- For surge protection, connect
equipment to the RJ45 port using
Ethernet/RJ45 cable.
The UPS is equipped with
two interface ports: a USB
port (Standard) and a 9-pin
RS232 port (Optional)
allowing advanced
communication network
between the UPS and a
computer (network).
1
2
3
4
5
1
2
3
4
5
6