background image

 

 

PROBOIL.2X user & installation guide v1e-2 

 

 

 

PROBOIL.2X

 

User & Installation Guide

 

 

 

                                  

www.proboil.co.uk 

        See top of boiler unit for contact details 

 

 

 

Please read these instructions carefully before 

installation or use and retain for future reference. 

 

You must install the tap and filter before the boiler.

 

 

 

We have a policy of continued product and quality development and improvement.  

Accordingly, we reserve the right to amend the specification at any time. All errors and omissions excepted. 

Summary of Contents for PROBOIL.2X

Page 1: ...Please read these instructions carefully before installation or use and retain for future reference You must install the tap and filter before the boiler We have a policy of continued product and qua...

Page 2: ...NK 18 1 3 TROUBLESHOOTING 21 1 3 1 BOILER SCREEN AND INTERFACE 21 1 3 2 WATER TEMPERATURE 21 1 3 3 WATER DRIPPING FROM THE SPOUT END WHEN THE HANDLE IS IN THE OFF POSITION 22 1 3 4 WATER FLOW RATE STR...

Page 3: ...must be carried out by authorised persons having knowledge and practical experience of the appliance in particular as far as safety and hygiene are concerned The PROBOIL system contains no user servic...

Page 4: ...e event of any suspected problem you should immediately cease usage isolate the water supply disconnect the power and contact the service agent noted on the top of the boiler WARNING This appliance mu...

Page 5: ...ct to your system and accordingly will invalidate your warranty If you have specific or unusual incoming water conditions please contact the service number on the boiler for further advice This applia...

Page 6: ...n is reached Fig 2 and the maximum flow is achieved It is normal for the hot water to take a moment to dispense as the water may empty from the product after use 3 After use ensure to close the 98 wat...

Page 7: ...rther 10 minutes 5 Dispense the entire contents of the boiler as normal until the heated water stream is entirely cold then allow it to continue to run for 5 minutes 6 Turn on the standard cold tap an...

Page 8: ...The water inside the boiler tank will not exceed 98 to ensure compliance to local safety laws Standby Touch sensitive key switches the unit between on and standby modes press and hold for 1 5 seconds...

Page 9: ...life is exceeded the product will beep daily to serve as an audible reminder We also operate a free reminder service when you register online In the event that power is interrupted to the boiler the f...

Page 10: ...large bowl or pan or jug or small bucket A cloth A permanent pen 1 Remove the new filter from its packaging and remove any end dust caps plugs from both ends of the filter 2 Write todays date on the...

Page 11: ...pipe from both ends of the filter cartridge To do this you should push the collet see drawing towards the centre of the filter whilst simultaneously pulling the blue flexible pipe in the opposite dire...

Page 12: ...on fig 1 c Once the Tee valve is open air within the filter will purge spitting is normal at first and the water will start to flow from the filter exit d Run the water into the bowl until it runs cle...

Page 13: ...er to around 2 litres per minute This can be checked with a timer and kitchen measuring jug c Once adjusted turn off the cold filtered water tap handle Fig 3 17 Turn the 98 C water handle fully on not...

Page 14: ...tion 1 Press and hold the key for 1 5 seconds to activate this will turn the boiler into standby mode 2 Unscrew and remove the aerator housing 1 anti clockwise use rubber gloves if you need to get a b...

Page 15: ...with plenty of water and seek medical advice After contact with skin wash immediately with plenty of water If swallowed seek medical advice immediately and show this container or label Descaler Ingre...

Page 16: ...similar to remove it 9 Whilst taking care lift the PROBOIL 2X A unit out from the cabinet and place it on the countertop 10 Each bottle of PROBOIL descaling solution contains 200ml of descaling solut...

Page 17: ...r than a further 30 minutes maximum for the descaler liquid to work It is normal for an odour to be present during this time 21 Remove the aerator from the end of the spout see previous section for de...

Page 18: ...C tap handle on fully run for at least 3 litres or until the stream runs fully cold 3 Pull the mains power plug out from the socket on the left hand face of the boiler 4 Unscrew and detach the blue in...

Page 19: ...found in the boiler inlet B whilst the boiler is upside down 11 Use only a non aggressive infant sterilising solution for example Milton concentrate Always read the label regarding the dilution The to...

Page 20: ...s normal for an odour to be present during this time 18 Turn the boiler back into standby mode 19 Turn on the 98 C tap handle on fully keep the handle on for a minimum of 5 minutes 20 Turn the boiler...

Page 21: ...use only contact service number on top of unit 1 3 2 Water temperature Issue description Possible issue solutions Water temperature is lower or higher than expected Press the keys and check the targe...

Page 22: ...water only to confirm the incoming pressure Water is dripping intermittently from the centre or outer channel of the spout end aerator typically shortly after each use This is water retained within th...

Page 23: ...onnecting the inlet adaptor G do not overtighten The boiler could be leaking from between the outlet adaptor and the boiler outlet Remove the outlet adaptor J and check that flat rubber seal I is pres...

Page 24: ...rms The manufacturer may where appropriate provide replacement parts for your product or repair or replace all or part of your product at their discretion under this warranty Any associated or ancilla...

Page 25: ...304 Selectable in tank temperatures 98 Maximum with adjustable heating point adjustment on screen 75 85 90 95 96 97 98 C range Heat up time From 20 C full and cold tank to 98 C displayed in Apx 9 minu...

Page 26: ...2L Min Filter life Once installed recommended replacement schedule is 6 Months or use of capacity whichever is sooner filter life varies by location and usage pattern The filter life indicator bar and...

Page 27: ...D ASPT1180 D1 1 flexible blue inlet pipe 1 5M E ASPT1180 E1 1 Inlet pushfit connector F ASPT1180 F1 1 Inlet wingnut connector With integral flat rubber seal G ASPT1180 G1 1 Inlet meshed filter seal H...

Page 28: ...roduct will be a problem do not progress the installation without rectifying it first 5 Check the tap hole is no further than 1 meter away from the planned location of the boiler outlet 6 Check the co...

Page 29: ...ly socket is earthed YES NO The power socket is permanently accessible by the customer YES NO The power socket is 13A and switched YES NO The power socket is within 1 4 meters of the boiler installati...

Page 30: ...without a filtered cold water dispense option you should have 2 hoses without any connection a A outlet hose ending with a pushfit connection this will be the cold water output to the filter cartridge...

Page 31: ...d exchange it avoid the rear of the cabinet if possible Always write the installation date on the filter label in permanent pen and leave the label on view it will help your customer as a visual remin...

Page 32: ...ep installation guide in this guide with due care Key Description Drawing A PROBOIL 2X boiler unit B male boiler inlet with internal check valve C 3 8 male boiler outlet D mains power cable E flexible...

Page 33: ...e level horizontally we suggest centres of 90mm at a minimum height of 245mm from floor level in the cabinet The boiler must be fixed to secure point to prevent accidental tipping of the boiler unit T...

Page 34: ...desired minimum pipe length with a permanent pen We recommend cutting the blue flexible pipe E at least 200mm longer than the required minimum pipe length to allow the boiler to be serviced more easil...

Page 35: ...cissors or similar 17 Firmly and fully push the silicone outlet tube K onto the red 3 8 x 8mm boiler outlet connector J Ensure the red 3 8 x 8mm boiler outlet connector J stem is clean of dirt or grea...

Page 36: ...a fully cold state it is normal that the tap may drip slightly from the spout centre channel during heating this will self adjust with use 5 After the boiler reaches its READY state repeat steps 1 2 6...