background image

 
 

 

 

PT Series Pressure Transmitters

 

User Manual 

 
 

 
 
 

 
 
 

 

 
 
 

 

ABUS TECHNOLOGIES INC. 

Summary of Contents for PT Series

Page 1: ...PT Series Pressure Transmitters User Manual ABUS TECHNOLOGIES INC ...

Page 2: ... to personal injury or death Therefore comply fully with all Warning and Caution notices Information in this manual is intended only to assist our customers in the efficient operation of our equipment Use of this manual for any other purpose is specifically prohibited and its contents are not to be reproduced in full or part without prior approval of Technical Communications Department ABUS Techno...

Page 3: ... 1 Features 2 Technical Parameters 4 4 5 3 Dimensions 5 4 Ordering Details 6 5 Connections Output Characteristics 7 8 6 Installation Recommendation 9 7 7 Operation 1 Zero and Span Adjustment Procedure 2 Example for Usage 9 9 10 8 Maintenance Troubleshooting 10 10 9 Safety Precautions 11 10 Warranty 11 ...

Page 4: ...There are no internal soft sealing materials that may react with the media or deteriorate over time The compact case is also made of stainless steel and is available with environmental protection ratings PT Series industrial Pressure transmitter adopts high performance chips and deals with special amplified chip integrative configuration and smart profile They are widely used in field of hydraulic...

Page 5: ...re 1 5 x F S Adjustability Zero Span 10 using potentiometers inside Electrical Connections M12 connector Five Pin bendix connector Hirschman Type or Direct down lead Process Connection G1 4 M20 x 1 5 1 4NPT Customized On request Pressure Inlet All media compatible with stainless steel 316 Operating temperature 40 85 C 125 C for short durations Higher range on request Ambient temperature 20 80 C We...

Page 6: ...p Powered Indicator 0 W O Indicator Zero and Span Adjustment 1 With Internal Z S 0 W O Example PT20 10 D 1 W LPI PT 1 STANDARD RANGES FOR PT SERIES CODE GAUGE ABS PRESSURE CODE COMPOUND 01 1 00 bar 17 600 00 bar 02 1 60 bar 18 1000 00 bar 03 2 50 bar 19 1500 00 Bar 04 4 00 bar 20 1800 00 Bar 05 6 00 bar 06 10 00 bar COMPOUND 07 16 00 bar 41 1 0 6 bar 08 20 00 bar 42 1 1 0 bar 09 25 00 bar 43 1 2 0...

Page 7: ...ABUS TECHNOLOGIES INC 7 PT 5 CONNECTIONS WIRE SIGNAL OUTPUT EXCITATION 2 wire 4 20mA 12 36 Vdc 3 wire 0 10 Vdc 12 18 Vdc ...

Page 8: ...ABUS TECHNOLOGIES INC 8 PT Output Characteristics FOR PT20 12XXXX Pressure Transmitter C D A B C D ...

Page 9: ...Four Terminals will be found on top of which will be a rubber washer Remove the rubber washer gently 3 This next step is crucial and to be done very gently Holding the PT in the palm of the hand press down the four terminals and revolve the thread such that the terminals do not move at all This is necessary as the wiring inside the casing might get twisted and the device will be damaged 4 After th...

Page 10: ...tput Check the wiring configuration Check the input power supply 2 No variation in output Check for leakage at pressure port point Check the span set of Indicating Instrument 3 Pressure not holding at constant input pressure Check for leakage pressure point Check for the connections ensure they are properly tightened ...

Page 11: ...g 10 WARRANTY ABUS provides the original purchaser of this instrument a one 1 year warranty against defects in material and workmanship under the following terms The one year warranty begins on the day of shipment as stated on the sales bill During the warranty period all costs of material and labor will be free of charge provided that the instrument does not show any evidence of misuse For mainte...

Reviews: