background image

 

 

Access-IS  

18 Suttons Business Park, Reading 
Berkshire, RG6 1AZ, United Kingdom 
Tel: +44 (0) 118 966 3333 
Web: www.access-is.com 
Email: support@access-is.com

 

 

 

 

 

Product names mentioned 
herein are for identification 
purposes only and may be 
trademarks and/or 
registered trademarks of 
their respective 
companies. 

 

© Copyright 2020 

ALL RIGHTS RESERVED

 

Subject:

 LSR116 Manual

 

Revision:

 4.6

 

Issue Date:

 12/08/2020 

LSR116 

1D/2D IP67 Barcode Imager 

Product Manual 

Summary of Contents for LSR110

Page 1: ...om Email support access is com Product names mentioned herein are for identification purposes only and may be trademarks and or registered trademarks of their respective companies Copyright 2020 ALL RIGHTS RESERVED Subject LSR116 Manual Revision 4 6 Issue Date 12 08 2020 LSR116 1D 2D IP67 Barcode Imager Product Manual ...

Page 2: ...vision reception which can be determined by turning the equipment on and off the user is encouraged to correct the interference with one or more of the following measures a Reorient or relocate the receiving antenna b Increase the separation between the equipment and the receiver c Connect the equipment to an outlet on a circuit different from that to which the receiver is connected d Consult the ...

Page 3: ... software 9 3 9 Troubleshooting 9 3 10 Maintenance 10 4 Operating modes 11 4 1 Mode summary 11 4 2 Dumb mode 12 4 3 Host mode 13 4 4 Interactive mode 15 5 Command reference 17 5 1 Basic configuration 17 5 2 Prefix and suffix solutions 18 5 3 LSR116 illumination 19 5 4 Indicator control 21 5 5 Development commands 22 5 6 Triggering 24 5 7 Counter 25 A HID reports 26 A 1 Receive data 26 A 2 Send com...

Page 4: ...unit with a small footprint easily integrated into kiosks and gates Fully sealed water resistant housing suitable for integration in indoor or outdoor kiosks gates and turnstiles RS232 and USB serial or keyboard interface options Fully configurable output data formats Interactive mode allows host application to control reader functions Reads barcodes from mobile phones tablets and paper Omnidirect...

Page 5: ...of 5 EAN13 Code 3 of 9 Code 128 plus others 2D PDF417 QR Aztec DataMatrix plus others Media supported Reads barcodes from mobile phones tablets and paper MTBF 85 000 hours Approvals CE EMC Class B EN 55022 EN 55024 CE Low Voltage Directive EN 60950 1 IEC 62471 2006 Exempt Class FCC 47CFR Part 15 Subpart B Class A 2 1 Part numbers Product Part Number Serial connected LSR116 LSR116 S XX USB power in...

Page 6: ...32 port or a USB port depending on the product version Note The cable is sealed into the unit to prevent entry of water moisture and dust Cable length is 2 m for the serial and USB versions 3 2 1 Connection to RS232 Figure 2 Connection to RS232 3 2 2 Connection to a USB port Figure 3 Connection to USB The LSR116 USB obtains power from the USB port Serial and power cable connected to LSR116 device ...

Page 7: ...y the baud rate parity data bits and stop bits Note A serial LSR116 communicates directly with the COM port and does not require any additional drivers to be loaded 3 4 2 USB connection Connect a USB LSR116 device using one of three possible options These options are compatible with all Linux and Windows operating systems from XP onwards 3 4 2 1 Keyboard interface Virtual keyboard using Windows or...

Page 8: ...D drivers In this instance HID reports exactly 64 bytes in length are sent between the host and the LSR116 The implementation of this driver and the method of interaction will depend on the version of the host operating system You should refer to the HID programming guide for the operating system you are using Refer to HID reports on page 26 for the details of the HID reports used with the LSR116 ...

Page 9: ...the driver before connecting the LSR116 to the host 3 6 3 2 HID interface without the Access driver There is no additional driver required for this mode Connect the USB cable from the LSR116 to a USB port on the computer 3 7 Test the device Once you have connected the device and installed the relevant drivers if applicable you can test the device To do this wave a piece of paper in front of the gl...

Page 10: ...code that you are scanning If scanning a document ensure that the print quality is good If scanning a barcode on a mobile phone ensure that you set the screen backlight on the phone to its brightest setting 3 10 Maintenance 3 10 1 Cleaning Clean the glass with a lint free cloth If the glass is dirty wipe the glass with a lint free cloth moistened with isopropyl alcohol or use an alcohol wipe Do no...

Page 11: ...ce The LSR116 waits for up to two seconds for an Accept Reject Ignore command to activate indicators The host sends an Ignore command to reset the imager if no response from the indicators is required The imager and illumination do not reset until the LSR116 sensor fails to detect any media for 0 5 seconds The Ignore command requires version 1 0 21 or later of the firmware 4 1 3 Interactive mode N...

Page 12: ...t Command to LSR Media placed in front of LSR116 Imager activated and barcode scanned Illumination activated as defined in the settings Data sent as configured USB Serial No media detected for 0 5 seconds LSR116 resets Media Detected Imager and Illumination Activated Barcode Read Data Sent to Host Lights Good Read as Settings Instruct Reader Idle Imager and Illumination Deactivated Reader Idle ...

Page 13: ...6 Host mode process flow Media Detected Imager and Illumination Activated Barcode Read Data Sent to Host Imager and Illumination Deactivated Accept or Reject Lights Bad Read as Settings Instruct Lights Good Read as Settings Instruct Reject Accept Reader Idle Reader Idle Ignore Command or No Response within Timeout ...

Page 14: ...d to Host Host Command to LSR Media placed in front of LSR116 Imager activated and barcode scanned Illumination activated as defined in the settings Data sent as configured USB Serial Host decides to accept or reject the data Bad Read AISXXR1 Lights activated as defined in the Bad Read settings No media detected for 0 5 seconds LSR116 resets 4 3 1 3 Ignore Comments LSR Command to Host Host Command...

Page 15: ...me Figure 7 Interactive mode process flow Media Detected Message Sent Requesting Trigger Send Trigger Imager and Illumination Activated Trigger Barcode Read Data Sent to Host Accept or Reject Lights Bad Read as Settings Instruct Lights Good Read as Settings Instruct Imager and Illumination Deactivated Reject Accept Reader Idle Untrigger Force Trigger Reader Idle Force Untrigger Ignore Command ...

Page 16: ...the data Good Read AISXXR0 Lights activated as defined in the Good Read settings No media detected for 0 5 seconds LSR116 resets 4 4 1 2 Good Read initiated by host sending trigger command Comments LSR Command to Host Host Command to LSR Host sends a command to trigger the imager This could be due to a second sensor 0x16 0x74 0x0D Imager activated it remains activated until untriggered or a Good R...

Page 17: ...urns the current value To query the stored value Send the six character command with a instead of the parameter and the LSR116 will return the command with the stored setting Note the must be followed with For example 0x16 0x4D 0x0D AISINF returns the current illumination mode To list parameter options Send the six character command with a instead of the parameter and the LSR116 will return the co...

Page 18: ... 1 Host mode 2 Interactive mode AISTAM Triggers Auto mode Only used when AISOMD is set to 2 Interactive 0 0 Normal operation 1 Automatic untrigger when media removed DLYGRD Sets the delay between successful reading of one barcode and the reading of another barcode Each unit is equivalent to 1 millisecond 2000 0 25000 5 2 Prefix and suffix solutions These commands allow you to add a prefix and or s...

Page 19: ...lumination commands Command Description Default Parameters Range AISILL Adaptive illumination mode see page 20 2 0 Off Phone only 1 Off Paper only 2 On Paper optimised 3 On Phone optimised AISONT Illumination on time Applies to AISILL modes 2 and 3 only adaptive illumination on Each unit is equivalent to 100 milliseconds 8 0 200 AISOFT Illumination off time Applies to AISILL modes 2 and 3 only ada...

Page 20: ...llumination off time 2 Applies to AISILL modes 2 and 3 only adaptive illumination on Each unit is equivalent to 100 milliseconds 2 0 200 AISOF3 Illumination off time 3 Applies to AISILL modes 2 and 3 only adaptive illumination on Each unit is equivalent to 100 milliseconds 5 0 200 5 3 1 Adaptive illumination modes The illumination modes allow you to configure the device to provide the best lightin...

Page 21: ...val AISGIN Good Read indication stop Specifies when the Good Read indicator extinguishes 1 0 At media removal 1 Continues after media removal AISBDT Bad Read LED indicator duration Each unit is equivalent to 100 milliseconds 8 0 200 AISBDS Bad Read duration start Specifies when the Bad Read indicator illuminates 0 0 At Bad Read 1 At media removal AISBIN Bad Read indication stop Specifies when the ...

Page 22: ... mode AISOMD2 If this flag is set then the TRIG messages from the LSR116 are sent only on media detect and media removed regardless of commands from the host 0 0 Disabled 1 Enabled AISRDS Changes the configuration back to its default values Warning This command resets all parameters to their default values including any values specific to your stored configuration 1 AISFWV Returns the version of t...

Page 23: ...sor reset is 48 64 112 Table 7 Status LED commands Command Description Default Parameters Range AISLS1 Status LED function 4 0 None 1 Power on 2 Loader 3 Power on and loader 4 Power on except when triggered 16 Brownout detection Diagnostic 32 Brownout reset Diagnostic 48 Brownout status Detection or reset Diagnostic 64 Intelli sensor reset Diagnostic 128 Watchdog reset Diagnostic AISLS2 Status LED...

Page 24: ...ill wait before reading a new barcode 2000 1000 30000 milliseconds SNSSMO Sensor maximum on time Set to 0 to disable this feature Each unit is equivalent to 100 milliseconds 600 60 seconds If the infrared sensor detects media for more than the timeout for example because there is a sticker on the glass it is disabled allowing the imager to work in presentation mode 600 0 60000 5 6 1 Interactive mo...

Page 25: ...5 7 Counter These commands display the number of Good or Bad reads made by the device Table 10 Counter commands Command Description Default Parameters Range AISGRC Good Read counter Cannot be reset 0 AISBRC Bad Read counter Cannot be reset 0 ...

Page 26: ...identifier 62 Reserved 63 Data cont d A 1 1 Example HID input reports as sent by the device In this example the decoded barcode contained 60 bytes of data which the device split into two HID reports Note that byte 63 in 0x01 in the first report and 0x00 in the second report indicates whether to expect more data or not In the second packet the remaining 52 bytes of data are set to 0x00 Bit Byte 7 6...

Page 27: ... 0 0 A 2 Send commands To send commands to the LSR116 use a HID out report with the following structure Bit Byte 7 6 5 4 3 2 1 0 0 Report ID 253 1 Data length 2 Output data up to 62 bytes 63 A 2 1 Example output report to request firmware version This example requests the firmware version from the LSR116 Bit Byte 7 6 5 4 3 2 1 0 0 253 1 0x0B 2 0x16 0x4D 0x0D AISFWV1 63 ...

Page 28: ... with the following structure Bit Byte 7 6 5 4 3 2 1 0 0 Report ID 4 1 Activate Good Read light Green Activate Bad Read light Red Initiate barcode read trigger Prevent barcode read untrigger Note You can only use trigger and untrigger commands in Interactive mode Good Read and Bad Read indicator controls are only available in Host or Interactive modes ...

Page 29: ...n 14 0E SO Shift out X on 15 0F SI Shift in X off 16 10 DLE Data line escape 17 11 DC1 Device control 1 oft XON 18 12 DC2 Device control 2 19 13 DC3 Device control 3 oft XOFF 20 14 DC4 Device control 4 21 15 NAK Negative acknowledgement 22 16 SYN Synchronous idle 23 17 ETB End of transmit block 24 18 CAN Cancel 25 19 EM End of medium 26 1A SUB Substitute 27 1B ESC Escape 28 1C FS File separator 29...

Page 30: ...2 Two 51 33 3 Three 52 34 4 Four 53 35 5 Five 54 36 6 Six 55 37 7 Seven 56 38 8 Eight 57 39 9 Nine 58 3A Colon 59 3B Semicolon 60 3C Less than or open angled bracket 61 3D Equals 62 3E Greater than or close angled bracket 63 3F Question mark 64 40 At symbol 65 41 A Uppercase A 66 42 B Uppercase B 67 43 C Uppercase C 68 44 D Uppercase D 69 45 E Uppercase E 70 46 F Uppercase F 71 47 G Uppercase G 72...

Page 31: ...racket 92 5C Backslash 93 5D Closing bracket 94 5E Caret circumflex 95 5F _ Underscore 96 60 Grave accent 97 61 a Lowercase a 98 62 b Lowercase b 99 63 c Lowercase c 100 64 d Lowercase d 101 65 e Lowercase e 102 66 f Lowercase f 103 67 g Lowercase g 104 68 h Lowercase h 105 69 i Lowercase i 106 6A j Lowercase j 107 6B k Lowercase k 108 6C l Lowercase l 109 6D m Lowercase m 110 6E n Lowercase n 111...

Page 32: ...IS 2020 DEC HEX Symbol Description 118 76 v Lowercase v 119 77 w Lowercase w 120 78 x Lowercase x 121 79 y Lowercase y 122 7A z Lowercase z 123 7B Opening brace 124 7C Vertical bar 125 7D Closing brace 126 7E Tilde 127 7F DEL Delete ...

Page 33: ...ontent updates 4 1 25 03 2015 Typographic amendments 4 2 01 02 2016 Style and content updates 4 3 15 03 2016 Minor content changes 4 4 30 10 2018 Update to Approvals section 4 5 12 12 2019 Updates to Specifications and Part numbers sections Installation section changed to indicate that power supply must comply with LPS 4 6 12 08 2020 Added note to Command reference introduction about following com...

Reviews: