background image

Swimming Pool Heat Pump

TCPO 

0

7

 

01G - TCPO 

0

9

 

01G

 

TCPO 11

 

01G

T

ECHNICAL INFORMATION

INSTALLATION

PLUG & PLAY

ECOLOGICAL

 

GAS

RENEWABLE 

ENERGIES

TITANIUM

 

EXCHANGER

SILENT

 

HEATERS

ABS

COVER

Operation and Installation Manual

Summary of Contents for S Series

Page 1: ...Pool Heat Pump TCPO 07 01G TCPO 09 01G TCPO 11 01G TECHNICAL INFORMATION INSTALLATION PLUG PLAY ECOLOGICAL GAS RENEWABLE ENERGIES TITANIUM EXCHANGER SILENT HEATERS ABS COVER Operation and Installatio...

Page 2: ...ons 11 How to use the mode 13 Failure code checking 26 MAINTENANCE and TROUBLESHOOTING 28 PARAMETER CHECKING AND ADUSTMENT 28 Parameter list 29 ENVIRONMENTAL INFORMATION 31 DISPOSAL REQUIREMENTS 32 WI...

Page 3: ...anced titanium heat exchanger guarantees long life span of heat pump free from corrosion and rust By using of titanium heat exchanger the heat pump could be applied with all types of water treatment s...

Page 4: ...of water Consult the dealer from whom you purchased the unit or a specialized installer Install the unit securely in a place When insufficiently installed the unit could fall causing injury When insta...

Page 5: ...k injury or fire Do not install the unit in a place where there is a chance of flammable gas leaks If there is a gas leak and gas accumulates in the area surrounding the unit it could cause an explosi...

Page 6: ...DE PRODUCT BOX Before starting the installation please make sure that all parts are found inside the box The Unit Box Item Image Quantity Swimming pool heat pump 1 Operation and Installation Manual 1...

Page 7: ...Swimming Pool Heat Pump S series OVERVIEW OF THE UNIT Unit Dimension mm Operation and Installation Manual 6 2016 02...

Page 8: ...flow of ventilated air towards a sensitive noise zone such as room window Avoid positioning pool heat pump on a surface that can transmit vibrations to dwelling Try to avoid placing appliance under a...

Page 9: ...cal circuit is well connected all cables tightened correctly at terminals and intermediate circuit breaker insulated and earthed correctly 4 The installation requirements described previously are stri...

Page 10: ...TRIC SHOCK OR FIRE NEVER PRESS THE BUTTONS OF THE DIGITAL CONTROLLER WITH A HARD POINTED OBJECT THIS MAY DAMAGE THE DIGITAL CONTROLLER NEVER INSPECT OR SERVICE THE DIGITAL CONTROLLER YOURSELF ASK A QU...

Page 11: ...wer off with the power on press key Power on Power off 2 Temperature setting With power on by adjust or by increase or decrease the set temperature Flash Initial state Press For example Press Operatio...

Page 12: ...meters During failure checking and p arameter checking press any of them to exit checking SETTING AND CONFIRM Long press it for more than 6 seconds you can check and adjust the parameters Press the UP...

Page 13: ...re under is the parameter number Outdoor ambient temperature symbol the figure under is the temperature value Parameter value symbol the figure under is the parameter value Failure symbol Bottom area...

Page 14: ...heat pump will automatically change to heating or cooling your pool depending on t he actual tempera ture to reach the desired temperature No electric heating Cooling mode Select for the cooling mode...

Page 15: ...he incoming water is greater than or equal to the required temperature X 2 C the compressor will enter cooling mode The compressor stops when the temperature of the incoming water will be equal to the...

Page 16: ...to the temperature of the water current in our example 27 Your screen will display Good to know about the operation of the cooling mode When the temperature of the incoming water is greater than or e...

Page 17: ...up to the temperature of the water current in our example 25 Your screen will display Good to know about the operation of the heating mode When the temperature of the incoming water is less than or eq...

Page 18: ...Swimming Pool Heat Pump S series Water temperature setting When the heat pump is switched on just press or to adjust water temperature Operation and Installation Manual 17 2016 02...

Page 19: ...clock setting the symbol flashes Step 2 press to select hour and the corresponding value flashes Step 3 press or to adjust the hour value Step 4 press to select minute and the corresponding value fla...

Page 20: ...ep 1 press twice to start ON time setting Step 2 press to select hour and the corresponding value flashes Step 3 press or to adjust the hour value Step 4 press to select minute and the corresponding v...

Page 21: ...tep 2 press to select hour and the corresponding value flashes Step 3 press or to adjust the hour value Step 4 press to select minute and the corresponding value flashes Step 5 press or to adjust the...

Page 22: ...figure below NO represents the timer sequence If it shows on bottom it means timer invalid Below examples show hot to set heat pump to switch on at 9 10 and switch off at 12 30 and switch on again at...

Page 23: ...Swimming Pool Heat Pump S series The 2nd ON OFF timer setting Operation and Installation Manual 22 2016 02 Press to turn to hour value...

Page 24: ...Swimming Pool Heat Pump S series The 3rd ON OFF timer setting Operation and Installation Manual 23 2016 02...

Page 25: ...Swimming Pool Heat Pump S series Timer mode setting The default mode is timer recurrence Please refer to following steps to set one day timer Operation and Installation Manual 24 2016 02...

Page 26: ...p S series Timer cancelling To cancel the timer please refer to the instruction for timer setting and set it to be via the M key Please check below example for cancelling timer Operation and Installat...

Page 27: ...ng When a failure occurs it will show failure symbol on the screen Press 2seconds you can check the failure code You can press it again to check another failure code if more than one occurs Press or t...

Page 28: ...high setting water temp 5 Bad connect of pressure switch 6 The pressure switch failure 7 Main PCB damaged 1 Check if the water pump works in good condition or adjust water control valve 2 Discharge an...

Page 29: ...house owners This operation is reserved to facilitate future service and maintenance All parameters should not be changed casually especially by house owners How to check and adjust parameters Step 1...

Page 30: ...justable Adjustable Adjustable Adjustable Unvalid Unadjustable 2 Meet set temperature 3 Water switch breakdown 4 Antifreeze finishing then stop the machine 5 Defrosting preparation 6 Defrosting off 7...

Page 31: ...should be cleaned of contaminants leaves twigs etc before each new heating period These types of contaminants can be manually removed using compressed air or by flushing with clean water It may be nec...

Page 32: ...nnot be reached Please check whether The permissible operating conditions for the heat pump have been adhered to air temperatures too high or too low The air inlet or outlet area is blocked restricted...

Page 33: ...smantle the system yourself the dismantling of the system treatment of the refrigerant of oil and other parts must be done by a quali ed installer in accordance with relevant local and national legisl...

Page 34: ...t water temp protection for cooling mode PC First step anti freeze protection in Winter PC Second step anti freeze protection in Winter E4 High pressure protection P9 Low pressure protection Pd Water...

Page 35: ...witch P3 Inlet water temp sensor failure P4 Outlet water temp sensor failure P1 Coil temp sensor failure P7 Ambient temp sensor failure P2 Discharge air sensor failure P8 Too low outlet water temp pro...

Page 36: ...3 8 55 9 89 COP 6 04 6 08 6 02 Air 35 C Water 27 C Inlet Cooling capacity KW 4 86 7 36 8 79 Power input A 1 68 2 47 3 03 Current A 7 66 11 29 13 20 EER 2 91 2 98 2 90 Power supply 220 240V 50Hz Max po...

Page 37: ...Swimming Pool Heat Pump S series Operation and Installation Manual 3 2016 02...

Page 38: ...NOTES...

Page 39: ...NOTES...

Page 40: ...inua evoluzione tecnologica dei prodotti ci riserviamo il diritto di variare le specifiche tecniche in qualsiasi momento e senza darne preavviso Avec le souci d am liorer sa production le constructeur...