background image

ARTICULATED ARM OPENERS

FOR RESIDENTIAL

USER MANUAL

24V DC GEAR MOTOR

PAPILLON250 User Manual

Summary of Contents for PAPILLON250

Page 1: ...ARTICULATED ARM OPENERS FOR RESIDENTIAL USER MANUAL 24V DC GEAR MOTOR PAPILLON250 User Manual ...

Page 2: ...e electrical power supply by turning off the magneto thermic switch connected upstream and apply the hazard area notice required by applicable regulations 3 Make sure the existing structure is up to standard in terms of strength and stability 4 When necessary connect the motorized gate to reliable earth system during electricity connection phase 5 Installation requires qualified personnel with mec...

Page 3: ... that the gate moves smoothly and that 1 Hinges are properly positioned and greased 2 No any obstacle in the moving area 3 No frictions between two leaf gates and on the ground while moving 4 Installation reference to open the gate with 90 degree please refer the data table below A Distance between the gate hinge and the wall bracket B Distance between the gate hinge and the motor side C Distance ...

Page 4: ...g surface of the brackets to be installed is smooth vertical and rigid 3 Arrange the cables for power supply cable of the motors make sure power supply cable is connected to motor 4 Motor installation and setting for mechanical stopper in opened and closed position 2 Place the gate in the full closed position and fix the U shaped fixing plate on the wall 1 Remove the upper cover and mechanical sto...

Page 5: ...adjustment 6 1 Adjust the gate to full opened position and after the position decided fixe with corresponding mechanical stopper 6 2 Adjust the gate to full opened position and after the position decided make the pointer on the limit switch aligned with the pointer on the curved arm Red points shown on the figure below indicate the pointers 1 2 6 WiFi Device Ports P button Wi Fi Paring Press 1 sec...

Page 6: ... transmitter should be properly aligned 4 Power up the photocells and make sure the LED light on receiver and transmitter are ON Step 1 Step 2 Step 3 Step 4 Detection Method Sensing Range Input Voltage Contact Current Response Time Emitting Element Operation Indicator Dimensions Output Method Current Consumption Connection Method Housing Material Water Proof Safety Standard Through Beam MAX 15m AC...

Page 7: ...ED Display LED2 Push button or Key selector LED3 Photocell 1 LED 4 Photocell 2 UP SET SET DOWN RF LEARN RF LEARN LED2 LED4 LED3 11 Lit Lit Lat Lat M1 M1 M2 M2 5V S1 S2 GND Lmt1 Lmt2 GND Lmt3 Lmt4 GND GND Ph1 Ph2 PhVcc PhVcc GND DKey SKey 26 24 25 23 21 22 19 20 18 16 17 15 13 14 11 10 12 9 8 6 7 5 3 4 1 2 F1 ...

Page 8: ...107 R106 R105 R104 R103 R102 J5 SW1 RF LEARN RF1 MOV1 K5 K3 K2 K1 J4 J3 J7 J2 F1 DB1 J8 SW4 SET SW5 DOWN NC NO CO NC NO CO CO NO NC CO NO NC NC NO CO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 LED2 LED3 LED4 M1 Limit1 Limit2 GND M1 Motor1 Power Limit Switch M2 Limit4 Limit3 GND M2 Motor2 Power Limit Switch ANT GND J5 RF1 J4 J3 J7 J8 NC NO CO CO NO NC CO NO NC NC NO CO 1 2...

Page 9: ... CO NC NO CO CO NO NC CO NO NC NC NO CO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 LED2 LED3 LED4 M1 Limit1 Limit2 GND M1 Motor1 Power Limit Switch Antenna ANT GND J5 RF J4 J3 J7 J8 NC NO CO CO NO NC CO NO NC NC NO CO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 LED2 LED3 LED4 M1 5V S1 GND M1 Motor1 Power Hall sensor Figure 2 5 Figure 2 6 Figure 2 ...

Page 10: ...he desired command according to the following table Within 10s press the desired button on the remote that you want it to be memorized figure 1 2 Make sure that the LED display flash the OSC or PED three times The code is corresponding to the selected command figure 2 3 Repeat step 1 2 within 10s if there have other remotes to be memorized for the same type of command No need within 10s the memori...

Page 11: ...trol board for 10 seconds 2 You will see DKY first and Hold the RF Learn until you see DAL All memory is deleted DKY DKY RF LEARN figure 3 5 sec Blink 5 times DKY RF LEARN figure 4 10 sec DAL RF LEARN LED2 D Key S Key Key selector or the push button is activated LED2 will be on LED4 Ph1 LED4 will be on when Ph1 are triggered LED3 Ph2 LED3 will be on when Ph2 are triggered Antenna M2 M1 Lat Lit Lmt...

Page 12: ... default setting Press and Hold the UP SET DOWN button for 5s and panel restores back to default setting Note 1 LED Shows D G tells the system learning has be completed for Dual Gate installation 2 LED Shows S G tells the system learning has be completed for Single Gate installation A Dual Gate 1 Slave Gate Close 2 Master Gate Close 3 Master Gate Open 4 Slave Gate Open 5 Slave Gate Close 6 Master ...

Page 13: ...y show OPN for 2s and then change to Amp current indication When the gate is stopped the LED Display show STP until next commend has been made after 10s no further movement the LED turns to OFF When the gate is closing the LED Display show CLS for 2s and then change to Amp current indication LED display shows S01 means the panel did not detected the M1 M1 and M2 M2 both been connected before the s...

Page 14: ...factory setting is F1 1 1 The factory setting is F2 2 1 The factory setting is F3 2 1 The factory setting is F4 3 1 The factory setting is F5 3 1 The factory setting is F6 2 1 The factory setting is F7 1 Press UP SET for 3 seconds to get into the program setting display from F1 Press UP or DOWN to change setting item from F1 to FJ Press SET button again to get into the sub settings Press UP or DOW...

Page 15: ...Gate Function OFF 0 1 sec 0 2 sec 0 3 sec 0 4 sec 0 5 sec 0 6 sec 1 The factory setting is F8 1 1 Auto close mode activates when the gates move to the end position or stopped manually If the transmitter push button or the key selector is activated before the auto close counting the gate will close immediately 2 The factory setting is F9 0 1 Please see 5 3 photocell adjustment for photocell logic 2...

Page 16: ...ad automatic closing time Safefy Device2 Safety Edge Open not allowed OPEN CLOSE not allowed Reverse to open for 2 seconds Reverse to close for 2 seconds Position of Gate When safety devices are activated FA 3 Open Only Device Vehicle detector Type of Safety Device FULLY CLOSED FULLY OPENED STOP DURING MOVING CLOSING OPENING Safefy Device1 Photocell CLOSE No effect Reload automatic closing time Op...

Page 17: ... Papillon250 24Vdc motor Electromechanical worm gear 2500N 250 kg per leaf 2 5 meters per leaf 20o C 50o C 256 x 187 x 267mm 6 kg Model Main power supply Back up battery Receiver board Installation Operating Temperature Dimension CB19 230Vac 110Vac 50Hz 60Hz 2pcs of batteries for emergency operation 1 3A each 433 92MHz 200 transmitters memory Built in PCBA 20o C 50o C 275mm x 195mm x 102mm 190mm 2...

Page 18: ...d in between Disconnect the power supply 1 Clean and lubricate the screws the pins and the hinge with grease 2 Check the fastening points are properly tightened 3 Maintain the wire connection are in good condition Connect the power supply 1 Check the power adjustments 2 Check the function of the manual release 3 Check the function of photocells or other safety devise ...

Page 19: ...ARTICULATED ARM OPENERS USER MANUAL 17 ...

Page 20: ...ety Durability Solid material apply with lasting usage EZ Instal Easy installation and user friendly interface Silence Worm gear application give silence operation Manual release device with easy use and highly protection Key Release 34100 124 16 A ...

Reviews: