background image

Summary of Contents for HYGIEA

Page 1: ......

Page 2: ...ght Source 7 4 3 Changing the Lamp 8 4 4 Lamp Replacement Warning 9 5 How To Set The Unit 9 5 1 Main Function 9 5 2 Home Position Adjustment 16 6 Control By Universal DMX Controller 18 6 1 DMX512 Connection 18 6 2 Address Setting 19 6 3 DMX512 Configuration 19 7 Error Information 25 8 Troubleshooting 28 9 Fixture Cleaning 29 1A ...

Page 3: ... unit will be overheated Before operation ensure that you are connecting this product to the proper voltage in accordance with the specifications in this manual or on the product s specification label It s important to ground the yellow green conductor to earth in order to avoid electric shock Minimum ambient temperature TA 0 Maximum ambient temperature TA 40 Do not operate this product at a lower...

Page 4: ...age or malfunction Please contact the nearest authorized technical assistance center if needed Disconnect this product from its power source before servicing DO use the original packaging if the device is to be transported Hot lamp explosion hazard DO NOT open the unit within 15 minutes after switching off DO replace the bulb once it is damaged deformed or life expired Avoid direct eye exposure to...

Page 5: ...r Shutter Smooth dimming from 0 100 outstanding strobe effect with variable speed Color wheel 1 x color wheel with 14 colors plus white Gobo wheel 1 x static gobo wheel with 15 gobos plus open Control DMX Channel 14 12 Channels Protocols DMX512 RDM Firmware Upgrade via DMX link Construction Display LCD display Data In Out 3 pin XLR 5 pin XLR is optional Power In Out Power Connector in out Protecti...

Page 6: ...Features Standard mode Ra 70 8 facet prism 16 facet prism both of them can rotate in both directions Dimension Weight 268x194x401mm 10kgs 10 6 x7 6 x15 8 in 22 1lbs Photometric Diagram 5A ...

Page 7: ...ove down in the menu ENTER To perform the desired functions 3 DMX IN For DMX512 link use 3 pin XLR cable to link the unit and DMX controller 5 pin XLR is optional 4 DMX OUT For DMX512 link use 3 pin XLR cable to link the next units 5 pin XLR is optional 5 POWERCON IN To connect to supply power 6 POWERCON OUT To connect to the next fixture 7 FUSE T 3 15A Protect the unit from damage of over current...

Page 8: ...rn off the lamp first via control panel or DMX controller and let the unit run at least five minutes to cool down before switching off the mains supply Never handle the lamp or luminary when it is hot Do not touch the bulb with bare hands If this happens clean the lamp with denatured alcohol and wipe it with a lint free cloth before installation The lamp generates UV radiation Never operate the la...

Page 9: ... lamp To replace the lamp 1 Ensure that the fixture is detached from power and has cooled down completely It is a good idea to allow the fixture to run for 10 minutes after the lamp has been turned off so that the cooling fans have time to works 2 Loosen the screws A on the head of the fixture and open the fixture head covers 3 Adjust the centrifugal screw B Unplug the leads of the lamp and lift t...

Page 10: ...lash the message Lamp Timeout Use Replace Lamp Now for up to 10 minutes After 10 minutes the fixture will return to normal operation Attention Damages caused by the failure to replace the bulb in time are not subject to warranty 5 How To Set The Unit 5 1 Main Function Turn on the unit press the MENU button into menu mode and press the UP DOWN button until the required function is shown on the moni...

Page 11: ...10A ...

Page 12: ...cks out if DMX signal stops Hold fixture continues to obey the last command it received Via DMX if DMX signal stops or Manual the fixture will automatically read the DMX value in the Manual Test menu for operation after selecting this mode press the ENTER button to store Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode View DMX Value To select View DMX ...

Page 13: ...MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode Lamp Settings To select Lamp Settings press the ENTER button to confirm use the UP DOWN button to select Lamp On Off or Lamp ON with Power Lamp On Off To select Lamp On Off press the ENTER button to confirm Use the UP DOWN button to select Off lamp off or On lamp on press the ENTER button to store Press the MENU bu...

Page 14: ...lish or Chinese press the ENTER button to store Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode Fixture Test To select Fixture Test press the ENTER button to confirm use the UP DOWN button to select Auto Test or Manual Test Auto Test Select Auto Test press the ENTER button to confirm the unit will run built in programs to automatically test pan tilt co...

Page 15: ...and max temperature of the fixture s CPU A B C will show on the display press the MENU button to exit Fan State To select Fan State press the ENTER button to confirm fan state will show on the display press the MENU button to exit Firmware Version To select Firmware Version press the ENTER button to confirm firmware version will show on the display press the MENU button back to exit RDM UID To sel...

Page 16: ... ENTER button to confirm use the UP DOWN button to select No or Yes the unit will run built in program to reset effect to their home positions press the ENTER button to store Press the MENU button to exit All Reset To select All Reset press the ENTER button to confirm use the UP DOWN button to select No or Yes the unit will run built in program to reset all motors to their home positions press ENT...

Page 17: ...ing time of the fixture Select the LAMP HOURS menu to display the running time of the lamp Select the LAMP STATE menu to turn on off the lamp Select the PAN INVERT menu and the fixture will run the pan invert mode Select the TILT INVERT menu and the fixture will run the tilt invert mode Select the RESET DEVICE menu the WARM RESET COLD RESET option will be displayed When WARM RESET is selected the ...

Page 18: ... to offset the value from 0 to 255 press the ENTER button to store Press the MENU button to exit Color Enter offset mode select Color press the ENTER button to confirm the present position will blink on the display use the UP DOWN button to offset the value from 128 to 127 press the ENTER button to store Press the MENU button to exit Gobo Enter offset mode select Gobo press the ENTER button to con...

Page 19: ...signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 3 The DMX output and input connectors are pass through to maintain the DMX circuit when one of the units power is disconnected 4 Each lighting unit needs to have a DMX address to receive the data by the controller The address number is between 1 512 5 The end of the DMX...

Page 20: ...press the ENTER button to store Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode Please refer to the following diagram to address your DMX512 channel for the first 4 units Channel mode Unit 1 Address Unit 2 Address Unit 3 Address Unit 4 Address 14 channels 1 15 29 43 12 channels 1 13 25 37 6 3 DMX512 Configuration Please control the fixture by referring...

Page 21: ...11 012 015 016 019 020 023 024 027 028 031 032 035 036 039 040 043 044 047 048 051 052 055 056 059 060 063 064 127 128 189 190 193 194 255 COLOR Open Color 1 Color 2 Color 3 Color 4 Color 5 Color 6 Color 7 Color 8 Color 9 Color 10 Color 11 Color 12 Color 13 Color 14 Color Wheel Indexing Clockwise Rotation Fast to Slow Stop Counter Clockwise Rotation Slow to Fast 8 000 007 008 010 011 013 014 016 0...

Page 22: ...obo 9 Gobo Shaking Slow to Fast Gobo 10 Gobo Shaking Slow to Fast Gobo 11 Gobo Shaking Slow to Fast Gobo 12 Gobo Shaking Slow to Fast Gobo 13 Gobo Shaking Slow to Fast Gobo 14 Gobo Shaking Slow to Fast Gobo 15 Gobo Shaking Slow to Fast Counter Clockwise Rotation Fast to Slow Stop Clockwise Rotation Slow to Fast 9 000 007 008 128 129 255 PRISM No Effect Prism1 8 facet prism Prism2 16 facet prism 10...

Page 23: ...o Function Lamp Off No Function 12 Channels Mode2 CHANNEL VALUE FUNCTION 1 000 255 PAN 0 540 2 000 255 PAN FINE 3 000 255 TILT 0 220 4 000 255 TILT FINE 5 000 255 PAN TILT SPEED Fast to Slow 6 000 255 DIMMER 0 100 7 000 007 008 015 016 131 132 139 140 181 182 189 190 231 232 239 240 247 248 255 STROBE Close Open Strobe from Slow to Fast Open Fast Close Slow Open Open Fast Open Slow Close Open Rand...

Page 24: ...064 068 069 072 073 076 077 080 081 084 085 089 090 093 094 097 098 101 102 105 106 110 111 114 115 118 GOBO Open Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 Gobo 6 Gobo 7 Gobo 8 Gobo 9 Gobo 10 Gobo 11 Gobo 12 Gobo 13 Gobo 14 Gobo 15 Gobo 1 Gobo Shaking Slow to Fast Gobo 2 Gobo Shaking Slow to Fast Gobo 3 Gobo Shaking Slow to Fast Gobo 4 Gobo Shaking Slow to Fast Gobo 5 Gobo Shaking Slow to Fast Gobo 6 Gob...

Page 25: ...ISM No Effect Prism1 8 facet prism Prism2 16 facet prism 11 000 127 128 189 190 193 194 255 PRISM ROTATION 0 100 Clockwise Rotation Fast to Slow Stop Counter Clockwise Rotation Slow to Fast 12 000 129 130 139 140 149 150 159 160 169 170 179 180 199 200 209 210 229 230 239 240 255 FUNCTION No Function Lamp On Reset X Y Reset Effect No Function No Function No Function Reset All No Function Lamp Off ...

Page 26: ... Check if there is any damage to the circuit of the pan motor drive board 3 Pan Encode Error Check if the pan encoder is damaged Check if the pan encoder is in poor contact with the lead of the PCB board or disconnected 4 Tilt Reset Error Check if the position of the tilt mounting magnetic steel falls off or is damaged Check if there are other interference items in the tilt operating range Check i...

Page 27: ...connected Check if the gobo wheel motor is damaged Check if there is any damage to the circuit of the gobo wheel motor drive board 8 Prism Reset Error Check if the position of the prism mounting magnetic steel falls off or is damaged Check if there are other interference items in the prism operating range Check if the prism Hall elements is damaged Check if the prism Hall elements is in poor conta...

Page 28: ...is damaged 14 HeadFan1 Too Low Check if the fan is out of order Check if there are other interference items in the fan operating range 15 HeadFan1 Too High Check if the fan is out of order Check if the fan circuit on the motherboard breaks down 16 BaseFan1 2 Start Err Check if the fan is not running Check if the fan leads are installed in place or disconnected Check if the fan is damaged Check if ...

Page 29: ...leshooting A The unit does not work no light and the fan does not work 1 Check the connected power 2 Measure the voltage 3 Check the power indicator to see whether it can be lit up or not B Not responding to the DMX controller 1 Check whether the DMX connectors and the DMX cables are connected correctly 2 Check whether the DMX address is correctly set 3 If the intermittent DMX signal problem occur...

Page 30: ...fan if necessary 9 Fixture Cleaning It is absolutely essential that the fixture is kept clean to ensure the maximum light output and allow the fixture to function reliably throughout its life The fixture must be cleaned regularly to avoid dust dirt and smoke fluid residues building up on or within the fixture The cleaning frequency depends on the application environment Clean the fixture immediate...

Page 31: ...30A ...

Page 32: ...Innovation Quality Performance ...