Tel. +49 (0) 36965 819–0
Fax +49 (0) 36965 819–361
1
I n s t a l l a t i o n n o t e s
ACO H a u s t e c h n i k
Service-Line
0154.31.13 A
As per: 04/2010
This operating-/assembly instruction applies for the
ACO Showerdrain Lightline LED showerdrain illumina-
tion and contains important information! It must be
handed out to the end user who must keep it in a safe
place!
ACO ShowerDrain Lightline
Product description
The ACO ShowerDrain Lightline illumination system consists of two
accumulator-operated LED modules and a charging device. The LED
modules are fixed to the stainless steel design gratings with the
fixing pins included in scope of supply.
The LED modules start lighting when coming in contact with water.
After taking a shower, the modules still light up for approx. two mi-
nutes before they switch off automatically.
Fig. 1
Charging process prior to initial use
Prior to initial use, the LED modules must be fully charged. This pro-
cess may take up to 18 hours. It must be made sure that the metal
contacts of the LED modules are free from dust, dirt and moisture.
Charging process during use
Depending on frequency of use, the LED modules must be rechar-
ged every three months. Before the LED modules are inserted in the
charging device, they have to be cleaned with warm water and to be
completely dried thereafter. The metal contacts of the LED modules
must be free from dust, dirt and soap residues.
Inserting the LED modules in the charger
It must be paid attention that the modules are correctly inserted
in the charging device. Please take correct positioning from fig. 1.
Lamps of LED modules must always point downwards.
Caution!
The charging device may be damaged if LED modules are
incorrectly inserted.
Control lamps at the charging device
Charging lamps state
Normal blinking
Rapid blinking
Permanent lighting
Meaning
Charging of LED modules takes place
Accumulator voltage already intensely dropped
or accumulator damaged. The charging device
nevertheless tries to recharge this LED module.
If, during the charging process, the charging
device does not switch over to slow blinking
(normal charging) within one hour, the LED mo-
dule is defective and may no longer be used.
Charging process finished