background image

  

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for RCL-50

Page 1: ......

Page 2: ... 1 954 981 3333 or email service acrelectronics com Please be ready to provide the technician with the page number you wish to discuss If you have a question that is not covered in the manual please visit our website and access the Frequently Asked Questions FAQs section for further information or call our Technical Service Department The website address is www acrelectronics com If in the future ...

Page 3: ...SECTION 4 REMOTE CONTROL SYSTEM_________________________ 5 SECTION 5 URP 102 POINT PAD _____________________________ 5 SECTION 6 URC 102 Master Controller _________________________ 9 APPENDIX B BULB REPLACEMENT PROCEDURE _________________ 14 APPENDIX C PRODUCT COMPONENTS ________________________ 15 APPENDIX E WARRANTY USEFUL LIFE POLICY NOTICES _________ 18 PLEASE READ ALL WARNINGS CAUTIONS AND NO...

Page 4: ...quality raw materials and quality controlled manufacturing produce a superior product The Test Facility at ACR can reproduce some of the harshest environmental conditions known to man This assures that the products we produce can stand up to the tough marine environment With proper care and maintenance your searchlight will be in service for years to come ACR is proud to be ISO 9001 certified the ...

Page 5: ...s it attractive for recreational and commercial vessels The searchlight is totally enclosed and is made of rugged aluminum alloy It is gasketed and finished to be resistant to the weather Mounting Make sure the area is clean and dry The searchlight can be mounted where desired using appropriate length 3 16 diameter stainless steel fasteners four 4 nylon shoulder washers are supplied with the RCL 5...

Page 6: ...tion Generally the Point Pad should be mounted in a protected area Install the surface mount Point Pad by drilling three 3 holes in the dashboard location using the Point Pad surface mount template supplied Mount the Point Pad to the dashboard using the gasket washers and nuts supplied Use a sealant around the bolt holes to protect from moisture intrusion When the flush mount option is selected cu...

Page 7: ...th all RCL 100 50 searchlights and with the URC 101 Master Controller CAUTION The URP 102 Point Pad is not recommended for use with the first generation URC 100 Master Controllers Figure 2 Point Pad Connection Block Diagram URP 102 Point Pad URP 102 Point Pad URP 102 Point Pad URC 102 Master Controller Unit URC 102 Master Controller Unit Power Source Power Source RG 59 Coaxial Cable RG 59 Coaxial ...

Page 8: ...Arrows to raise or lower the Searchlight beam To activate the XRCiZ feature press and hold the ON OFF button for greater than 5 seconds The green LED indicates XRCiZ feature is enabled To deactivate the XRCiZ feature Press and hold the ON OFF button for greater than 5 seconds The red LED indicates XRCiZ feature is disabled An LED blinking red green indicates that the XRCiZ feature is now exercisin...

Page 9: ...Y1 03 0141D 8 Figure 4 URP 102 Point Pad Surface Mount Case Figure 5 URP 102 Point Pad Flush Mount Case ...

Page 10: ...our mounting location Use a sealant in fastener holes to prevent moisture intrusion General wiring scheme The RCL 50B has a unique wiring scheme Special attention must be paid to the following chart The Master Controller is supplied with an in line fuse holder on the orange power lead Use only 15 amp fuses in this fuse holder See Figure 9 for the master controller wiring diagram WARNING Failure to...

Page 11: ...e coax has been routed strip the insulation and crimp the F connectors in place Screw the F connectors to the master controller and the Point Pad Wiring to Power Supply The power source must be a fused 12 VDC 5 amp supply or 24 VDC 3 amp supply Following the wiring scheme in Table 1 use the supplied butt connectors to connect the Master Controller to the power source Refer to Table 2 for proper wi...

Page 12: ...Point Pad button will stop the current cycle and leave the searchlight to follow any additional commands To deactivate the XRCiZ feature press and hold the Point Pad on off button for greater than 5 seconds The red LED on the URC 102 Point Pad indicates that the XRCiZ feature is disabled NOTE LED feedback is not available when using RCL 100 or URC 101 Point Pads NOTE The searchlight should not be ...

Page 13: ...Point Pads 75 ohm TV Coaxial Cable 75 ohm TV Coaxial Cable T Connector or Optional 75 Ohm Splitter for Multiple RCL 100 Point Pads Ground Blue Orange Note Wiring must be in accordance with this diagram Improper wiring will damage components 12 VDC or 24 VDC Master Controller in line 15 amp fuse Power Source Fuse Figure 7 URC 102 Master Controller Wiring Diagram ...

Page 14: ...Y1 03 0141D 13 Figure 8 URC 102 Master Controller ...

Page 15: ...ACR dealer or through ACR Electronics The part numbers are P N 6002 for 12V units and P N 6010 for 24V units CAUTION Failure to follow replacement instructions carefully can result in damage to bulb and or light All part sales are final To replace the lamps 1 Disconnect unit from power source and allow bulb to cool 2 Remove three screws holding the front flange and glass in place 3 To remove the o...

Page 16: ... 0776 Washers 2 A1 05 0777 Warranty Card 1 A1 20 1019 Product Support Manual 1 Y1 03 0141 Mounting Templates 1 Y1 03 0138 1 Product No 1940 3 RCL 50B 24 V Searchlight Installation Kit includes Description Quantity ACR Part Number Searchlight RCL 50B 24 V 1 A3 06 0092 4 Kit Nylon Washers 4 1 A3 06 1940 Connector F 2 A1 03 0220 Cable Coaxial 15ft A2 07 0002 6 Master Controller URC 102 1 A3 06 2231 C...

Page 17: ...R Part Number Point Pad URP 102 with Surface Mount Case 1 A3 06 2230 Case Flush Mount 1 A1 18 1875 2 Gasket Surface Mount 1 A1 25 0140 1 Gasket Flush Mount 1 A1 25 0140 2 U Clamp 2 A1 17 1366 Nuts Nylon lock 2 A1 05 0776 Washers 2 A1 05 0777 Adapter Plate Flush mount 1 A1 18 1871 Adapter Plate Surface mount 1 A1 18 1892 Instruction Sheet Point Pad 1 Y1 06 0179 Mounting Templates 1 Y1 03 0138 1 Pro...

Page 18: ... 4 A1 03 0220 Instruction Sheet Point Pad 1 Y1 06 0179 Mounting Templates 1 Y1 03 0138 1 Product No 9283 3 Remote Control Installation Kit Includes Description Quantity ACR Part Number Master Controller URC 102 1 A3 06 2231 Connector In Line 8 A1 03 0222 Point Pad URP 102 with Surface Mount Case 1 A3 06 2230 Case Flush Mount 1 A1 18 1875 2 Gasket Surface Mount 1 A1 25 0140 1 Gasket Flush Mount 1 A...

Page 19: ...ars for the following products EPIRB PLB S VDR SSAS Useful Life Policy The typical service life of a properly maintained Product is limited to 12 years from date of manufacture Products that are 12 years and 1 month or older from date of manufacture will not be serviced by ACR or our Battery Replacement Centers A Product that is 12 or less years old from date of manufacture will be serviced as lon...

Page 20: ...ns EN 60945 2002 Immunity IEC 61000 4 2 1995 Electrostatic Discharge IEC 61000 4 3 1995 Radiated Immunity IEC 61000 4 6 1996 Conducted Immunity Power and I O Leads IEC 61000 4 11 1994 Voltage Dips and Interrupts Manufacturer ACR Electronics Inc European ACR Electronics Inc 5757 Ravenswood Road Representative European Office Fort Lauderdale FL 33312 1 Rose Cottages Pitmore Lane USA Sway Lymington H...

Reviews: