Product Overview

The ACTpro 100 and ACTpro 100PCB door expanders
work in conjunction with the ACTpro 2000 / 3000 
two door controllers.  They facilitate the expansion of 
the controller from two to a max of sixteen doors.  
Each ACTpro 100 or ACTpro 100PCB allows the 
addition of one extra door.  The ACTpro 100 has 
durable polycarbonate housing, is surface mounted  
and suitable for indoor use only.  The ACTpro 100PCB 
has no housing and fits easily into the ACTpro 200 or 
standard PSU boxes.

 

For details of the ACTpro 200 please see overleaf

Features include:

Single door expanders for ACTpro 2000 
and ACTpro 3000 controllers 

Maximum of 14 ACTpro 100 or ACTpro 100PCB 
door expanders to each ACTpro 2000 and 
ACTpro 3000

Programmable inputs and outputs

Auxiliary relay output 

Require 12 Volt DC supply

Supports entry/exit readers
ACTpro 100PCB has no casing allowing quicker
installation

Installation / Specification Guidelines

For indoor use only

The ACTpro 100 and ACTpro 100PCB are
compatible with all versions of ACTpro 2000 
and ACTpro 3000 controllers

ACTpro 200, ACTpro 100 and ACTpro 100PCB 
may be connected on the same network

ACT

pro 

100 / 100PCB 

Single Door Expander 

Access Control Technology  

Unit C1, South City Business Park, Tallaght, Dublin 24, Ireland.

t:

 353 (0) 1 466 2570.  

f:

 353 (0) 1 452 0427.  

e:

 sales@accesscontrol.ie.  

w:

 www.accesscontrol.ie

Ordering Information

ACTpro 100 Door Station

ACTpro 100

ACTpro 100 PCB Door Station

ACTpro 100PCB

Cabling Chart

From 

 

To

Cable

Restriction

Reader

ACTpro 100 or 

ACTpro 100PCB

ACTpro 2000 or

ACTpro 3000

Network RS485

Interface

Controller

ACTpro 2000 or

ACTpro 3000

PC Direct RS232

PC

8 core screen

Twisted screen 

pair Belden 9502 

or equivalent or 

Cat5

Twisted screen 

pair Belden 9502 

or equivalent or 

Cat5

Cable supplied

30m at 5 Volts

100m at 12 Volts

Maximum 1.4km

Maximum 30m

Maximum 30m

Product Specification

Operating Voltage: 

Consumption: 

 

Weight:   

 

 

      

Operating Temperature: 

Dimensions 

(HxWxD, mm): 

Mounting: 

 

Installation: 

 

12V DC

40 / 120 mA

414 grams 

      

-10 to +50 C

110 x 190 x 60

Surface

Indoor

12V DC

40 / 120 mA

80 grams 

      

-10 to +50 C

80 x 130 x 25

Inside PSU

Indoor




ACT

pro 

100

ACT

pro 

100 PCB

ACT

pro 

100

ACT

pro 

100PCB

ACTpro 200 door station 

with 3 Amp Monitered PSU

2000/3000

200

100

100

C

M

Y

CM

MY

CY

CMY

K

Reviews: