d. Connect  the  test  leads  to  the  circuit  under  test,  observing  proper

polarity.

e. Read  the  results  on  the  digital  display.  If  the  display  reads  overrange

(1.), switch to a higher range within the milliamps function.

3.DC 10 AMPS MEASUREMENT

a. Set the SELECTOR switch to the 

10 A

mps position.

b. Plug the 

BLACK 

test lead into the

 COM

mon input jack on the

multitester.

c. Plug the 

RED 

test lead into the 

10 A

mps input jack on the multitester.

d

.

Connect  the  test  leads  to  the  circuit  under  test,  observing  proper

polarity.

e. Read the result on the digital display.

4.RESISTANCE MEASUREMENT

a. Set the SELECTOR switch to the required resistance 

 (ohms)

position.

b. Plug the 

BLACK 

test lead into the 

COM

mon jack on the multitester.

c. Plug the 

RED 

test lead into the 

V

olts 

 (ohms) 

m

illi

A

mps input jack on

the multitester.

d. Connect the test leads to the circuit under test.
e. Read the result on the digital display. If the display reads overrange

(1.),  switch  to  a  higher  range  within  the  resistance  function.

5.DIODE CHECK

a. Set the SELECTOR switch to the diode

position.

b. Plug the 

BLACK

 test lead into the 

COM

mon input jack on the

multitester.

c. Plug the 

RED 

test lead into the

 V

olts 

 (ohms) 

m

illi

A

mps input jack on

the multitester.

d. Connect the test leads to the diode under test. The diode must be

removed from the circuit to achieve proper results.

e. Read the result on the digital display.
f. Reverse the test lead connections at the diode.
g. Read the result on the digital display.
h. A good diode will show a low reading with the test leads connected

one way, and infinity (1.) with the test leads connected the other

way. The low reading will typically be some three-digit number on

the display. The actual number is not critical.

FUSE REPLACEMENT:

All milliamp ranges of this miltitester are  fuse protected. Should you exceed

2 amperes of current flow in any of these ranges, the fuse may open. To

maintain safe operation of the multitester, replace it only with a 2 Amp, 250

Volt, 5mm x 20mm fast-acting glass fuse. Replace the fuse as follows:
1.Turn the SELECTOR switch OFF.
2.Remove the bottom case half.
3.Remove the battery.
4.Using a small blade screwdriver or other suitable tool, gently pry the

open fuse out of its holder.

5.Install  a  new  fuse.
6.Re-install the battery, and bottom case half.

REPLACEMENT PARTS

The following replacement parts are available for your multitester. Consult

your  retailer  or  the  manufacturer  for  assistance.

PART NUMBER

DESCRIPTION

0002-2274

Instruction Manual

0044-0108

2 Amp 250 Volt Fuse

0038-1748

Black Test Lead Assembly

0038-1749

Red Test Lead Assembly

DC Current

Range

Resolution

Accuracy

Voltage Burden

200µA

0.1µA

2000µA

1µA

250mV rms Max.

20mA

10µA

± (1.2% rdg + 2 dgts)

200mA

100µA

2000mA

1mA

± (1.5% rdg + 2 dgts)

700mV rms Max.

Overload protection: mA Input: 2A/250V fuse

DESCRIPTION AND SPECIFICATIONS

DESCRIPTION:  The Digital Multitester is a compact, hand-held, easy to use

precision instrument which is compatible both with home electrical applica-

tions, as well as the electrical systems used in modern passenger cars and

trucks. It may also be used to measure voltages in the computer control

circuits  of  computer-controlled  vehicles.

SPECIFICATIONS:

Display  – 

 3 1/2 digit, .5 inch LCD (Liquid Crystal Display)

Automatic Polarity Sensing

  

–

  Display shows a minus (-) sign on the DC

Volts  and  Amps  functions  when  lead  hookup  is  reversed.

Zero  adjustment

   

–

    Unit  automatically  zeroes  on  the  Volts  and  Amps

functions.

Overrange indication 

 

–

  Left side of display shows either “1” or “-1” when

range in a function is exceeded.

Operating temperature

  

–

  0°C - 35°C (32°F - 95°F), 0-80% R.H.; 35°C -

50°C (95°F - 122°F), 0-70% R.H.

Measurement  rate

   

–

    2.5  measurements  per  second,  nominal

Power –  

Nine (9) volt alkaline or carbon zinc battery

Battery life

  

–

Alkaline: 200 hours typical

Carbon zinc: 100 hours typical

Accessories

  

–

  Test leads (pair), instruction manual

FUNCTIONS AND DISPLAY:
The  analyzer  provides  the  following  functions  and  displays  them  as

indicated.

OFF - 

To preserve battery life always return the rotary switch to

 

OFF when

testing is complete.
Accuracies are ± (% r No. of digits) at 23°C ± 5°C (75°F ± 3°F), less

than 75% R.H.

SAFETY GUIDELINES

SAFETY EQUIPMENT
Fire  Extinguisher

Never work on your car without having a suitable fire

extinguisher handy. A 5-lb or larger CO

2

 or dry chemi-

cal unit specified for gasoline/chemical/electrical

fires is recommended.

Fireproof  Container

Rags and flammable liquids should be stored only in

fireproof, closed metal containers. A gasoline-soaked

rag should be allowed to dry thoroughly outdoors

before being discarded.

Safety  Goggles

We recommend wearing safety goggles when work-

ing on your car, to protect your eyes from battery acid,

gasoline, and dust and dirt flying off moving engine

parts.

NOTE:

 Never look directly into the carburetor throat

while the engine is cranking or running, as sudden

backfire can cause burns.

LOOSE CLOTHING AND LONG

HAIR (MOVING PARTS)

Be very careful not to get your hands, hair or clothes

near any moving parts such as fan blades, belts and

pulleys or throttle and transmission linkages. Never

wear neckties or loose clothing when working on

your car.

JEWELRY

Never wear wrist watches, rings or other jewelry

when working on your car.  You’ll avoid the possibil-

ity of catching on moving parts or causing an electri-

cal short circuit which could shock or burn you.

VENTILATION

The carbon monoxide in exhaust gas is highly toxic.

To avoid asphyxiation, always operate vehicle in a

well-ventilated area. If vehicle is in an enclosed area,

exhaust should be routed directly to the outside via

leakproof exhaust hose.

SETTING THE BRAKE

Make sure that your car is in 

Park

 or 

Neutral

, and that

the 

parking brake is firmly set.

 

CP7674 DIGITAL MULTITESTER

INSTRUCTION MANUAL

Your  Digital  Multitester  is  designed  for  both  home  and  automotive  use.  The  following  Safety

Guidelines are provided when it is used for engine or vehicle testing. To prevent accidents that

could  result  in  serious  injury  and/or  damage  to  your  vehicle  or  test  equipment,  carefully  follow

these safety rules and test procedures.

NOTE:

 Some vehicles have an automatic release on

the parking brake when the gear shift lever is re-

moved from the PARK position. This feature must be

disabled when it is necessary (for testing) to have the

parking brake engaged when in the DRIVE position.

Refer to your vehicle service manual for more infor-

mation.

HOT SURFACES

Avoid contact with hot surfaces such as exhaust

manifolds and pipes, mufflers (catalytic converters),

radiator and hoses.  Never remove the radiator cap

while the engine is hot, as escaping coolant under

pressure may seriously burn you.

SMOKING AND OPEN FLAMES

Never smoke while working on your car.  Gasoline

vapor is highly flammable, and the gas formed in a

charging battery is explosive.

BATTERY

Do  not  lay  tools  or  equipment  on  the

battery. Accidentally grounding the “HOT”

battery terminal can shock or burn you and

damage wiring, the battery or your tools

and  testers.  Be  careful  of  contact  with

battery  acid.  It  can  burn  holes  in  your

clothing and burn your skin or eyes.

When operating any test instrument from an auxiliary

battery, connect a jumper wire between the negative

terminal of the auxiliary battery and ground on the

vehicle under test. When working in a garage or other

enclosed area, auxiliary battery should be located at

least  18  inches  above  the  floor  to  minimize  the

possibility of igniting gasoline vapors

HIGH VOLTAGE

High voltage – 30,000 to 50,000 volts – is present in

the ignition coil, distributor cap, ignition wires and

spark plugs.  When handling ignition wires while the

engine is running, use insulated pliers to avoid a

shock.  While not lethal, a shock may cause you to

jerk involuntarily and hurt yourself.

JACK

The jack supplied with the vehicle should be used

only for changing wheels. Never crawl under car or

run engine while vehicle is on a jack.

VEHICLE SERVICE INFORMATION

The  following  is  a  list  of  publishers  who  have  service  manuals  for  your

specific vehicle. Write or call them for availability and prices, specifying the

make,  style,  model  year  and  VIN  (Vehicle  Identification  Number)  of  your

vehicle.

AFTERMARKET  VEHICLE  SERVICE  MANUALS

Motor’s Auto Repair

Manual

Hearst  Company

250 W. 55th Street

New York, NY 10019

ORIGINAL  EQUIPMENT  MANUFACTURERS'  VEHICLE  SERVICE  MANUALS

Chilton Book Company

Chilton  Way

Radnor, PA 19089

American Motors,

Chrysler  Corporation,

Nissan, North America

Dyment  Distribution

Services

20770 Westwood Drive

Strongsville, OH 44136

(216) 572-0725

Buick

Tuar Company

Post  Office  Box  354

Flint, MI 48501

Oldsmobile

Lansing Lithographers

Post Office Box 23188

Lansing, MI 48909

Toyota Motor

Corporation

Toyota  Service

Publications

750 W. Victoria St.

Compton, CA 90220-5538

CA residents:

1-800-443-7656

Outside CA:

1-800-622-2033

Cadillac,  Chevrolet,

Pontiac

Helm Incorporated

Post Office  Box 07130

Detroit, MI  48207

Ford  Publications  Dept.

Helm Incorporated

Post Office Box 07150

Detroit, MI 48207

Honda  Motor  Co.,  Ltd.

Helm Incorporated

Post Office Box 07280

Detroit, MI 48207

(313) 883-1430

Cordura Publications

Mitchell Manuals, Inc.

Post Office Box 26260

San Diego, CA. 92126

AC Volts

Accuracy

Overvoltage

Range

Resolution

(45Hz-450Hz)

Protection

200V

100mV

DC 750V

750V

1V

AC  750V

Input Impedance: 450K

± (1.2% rdg + 5 dgts)

DC Volts

Overvoltage

Range

Resolution

AccuracyProtection

200mV

100µV

DC 500V

AC  350V

2000mV

1mV

20V

10mV

DC 1100V

200V

100mV

AC   800V

1000V

1V

Input Impedance:  10m

± (0.75% rdg + 2 dgts)

DC 10A

Range

Resolution

Accuracy

Voltage  Burden

10A

100mA

± (1.5% rdg + 3 dgts)

300mV rms Max.

Overload protection: unfused up to 10A for 15 seconds

Resistance

Max.  Open

Range

Resolution

AccuracyCircuit  Voltage

200

0.1

2000

1

20K

10

± (1.0% rdg + 4 dgts)

3.2V

200K

100

2000K

1K

Diode Check

Use this test to check for open or shorted diodes. A good diode will show

a low reading with the test leads connected in one polarity, and a high reading

with the test leads connected in the other polarity. The low reading will be

typically some three-digit number on the display (for example: .673). The

actual number is not critical. The high reading should be infinity (1.).

PRECAUTIONS AND PREPARATION FOR

MEASUREMENT:

1.Be sure that a fresh nine (9) volt battery is correctly installed in the

multitester.

2.Compare the position of the selector switch with the anticipated test

result. In the case of voltage or current measurement, always select a

range which is high enough to handle the worst case result! Voltage or

current may be higher than you expect.

3.The 

BLACK 

test lead is always inserted in the 

COM

mon jack on the

multitester. The 

RED 

test lead must be inserted in either the 

V

olts

(ohms) 

m

illi

A

mps jack, or the 

10

 

A

mps jack depending on the test

being  performed. 

Incorrect  placement  of  the  RED  test  lead  may

damage  the  multitester,  the  circuit  under  test,  or  both!

4.

The  10  Amp  range  on  the  multitester  is  not  fused.  Exercise

extreme  caution!

5.Operate the multitester only in temperatures between 0°C and 50°C

(32°F - 122°F), and at 80% or less relative humidity.

6.Turn the SELECTOR switch  to the OFF position when testing is

completed.  If  the  multitester  will  not  be  used  for  an  extended  period  of

time, remove the internal nine (9) volt battery to avoid damage from

leakage.

7.Do not store the multitester in direct sunlight, or in areas of high

temperature or high humidity.

MEASUREMENT  PROCEDURES:

1.VOLTAGE MEASUREMENT

a. Set the SELECTOR switch to the required AC or DC voltage position.
b. Plug the 

BLACK 

test lead into the 

COM

mon input jack on the

multitester.

c. Plug the R

ED 

test lead into the 

V

olts 

 (ohms) 

m

illi

A

mps input jack on

the multitester.

d. Connect the test leads to the circuit under test, observing proper

polarity when measuring DC voltage.

e. Read the result on the digital display. If the display reads overrange

(1.), switch to a higher range within the appropriate AC or DC function.

2.DC MILLIAMP MEASUREMENT

a. Set the SELECTOR switch to the required DC milliamp position.
b. Plug the 

BLACK 

test lead into the 

COM

mon input jack on the

multitester.
c. Plug the 

RED 

test lead into the 

V

olts 

 (ohms) 

m

illi

A

mps input jack on

the multitester.

Reviews: