background image

           INSTALLATION INSTRUCTIONS

              ATB2 SERIES LUMINAIRES

American Electric Lighting a division of Acuity Brands Lighting

DRAWING NO. A72975   REV: A   (FRONT)

©2014 ACUITY BRANDS LIGHTING, INC. ALL RIGHTS RESERVED.

PART NUMBER 057-70-72975

WARNING

             DISCONNECT POWER BEFORE RELAMPING OR WIRING THE FIXTURE. 

        READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION

TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL 

         AND LOCAL ELECTRICAL/BUILDING CODES. FOR CODE INTERPRETATION, CONSULT LOCAL CODE AUTHORITY

RISK OF FIRE. PRODUCT FOR OUTDOOR INSTALLATION AND USE ONLY.

WARNING

CAUTION

!

!

!

WARNING

   ENSURE THAT ALL POWER IS 

DISCONNECTED PRIOR TO WIRING

!

MOUNTING / LEVELING

:

DETERMINE THE SIZE OF THE MAST ARM.  THIS LUMINAIRE IS 
DESIGNED TO ACCOMMODATE A MAST ARM FROM 1/1/4" TO 2" 
DIA. THE LUMINAIRE IS FACTORY SET TO MOUNT TO THE 1-1/4" 
ARM. TO MOUNT TO A 2" ARM, A MODIFICATION MUST BE MADE.
THE REAR OPENING MUST BE ENLARGED. KNOCKOUTS ARE 
CAST-IN AROUND THE REAR OPENING FOR THIS PURPOSE. TO 
REMOVE THIS EXCESS MATERIAL, STRIKE WITH A HAMMER OR 
GRASP WITH PLIERS AND BREAK OFF.

 CAUTION

OVER-TORQUING OF FITTER CLAMP BOLTS CAN 

  CREATE CRACKS IN THE HOUSING CAUSING 

    THE FIXTURE TO FALL TO THE GROUND.

!

WIRING:

PULL UP TERMINAL BLOCK COVER (OPTIONAL) AS SHOWN IN 
THE PICTURE. FEED THE SUPPLY WIRES THROUGH THE MAST
ARM, DRESS THEM SO THEY DO NOT INTERFERE WITH ANY
COMPONENTS AND SO THEY WILL NOT BE PINCHED IN THE
DOOR, AND CONNECT THEM TO THE PROPER TERMINALS ON
THE TERMINAL BLOCK. VERIFY THE SUPPLY VOLTAGE IS 
CORRECT AS NOTED ON THE NAMEPLATE LABEL. IF SUPPLIED,
PUSH DOWN THE TERMINAL BLOCK COVER TO KEEP 
TERMINALS COVERED.

OPTIONAL PHOTOCONTROL:

PLUG THE PHOTOCONTROL INTO THE RECEPTACLE ENSURING
GASKET IS FIRMLY SEATED. TWIST CLOCKWISE UNTIL IT LOCKS 
INTO POSITION.
IF PHOTOCONTROL RECEPTACLE ROTATION IS REQUIRED, LOOSEN
THE TWO PHILIPS HEAD RECEPTACLE SCREWS. ROTATE
RECEPTACLE, MAXIMUM OF 360° , THEN RE-TIGHTEN SCREWS
UNTIL SNUG, USING 

20-25 IN-LBS

 OF TORQUE.

IF PHOTOCONTROL RECEPTACLE ROTATION IS REQUIRED
FOR THE P5 / P7 OPTION, LOOSEN THE TWO PHILIPS HEAD 
RECEPTACLE SCREWS COMPLETELY. ROTATE RECEPTACLE 90°, 
180°, OR 270°, THEN RE-TIGHTEN SCREWS UNTIL SNUG, USING 

20-25 IN-LBS

 OF TORQUE.

WARNING

 FIXTURE MUST BE GROUNDED

   TO FUNCTION AS INTENDED

!

KNOCKOUT

FITTER BOLTS MAST ARM

TERMINAL 

BLOCK COVER

TERMINAL 

BLOCK

ANGLE LEVELING:

THIS LUMINAIRE IS DESIGNED TO ADJUST ± 5 DEGREES UP OR
DOWN SIDE. TO ADJUST THE LUMINAIRE TO THE UP SIDE, TIGHTEN
THE REAR FITTER BOLTS UNTIL GET THE DESIRED ANGLE, AND
THEN TIGHTEN THE FRONT FITTER BOLTS TO SECURE THE
LUMINAIRE. TO ADJUST TO THE DOWN SIDE TIGHTEN THE FRONT
FITTER BOLTS UNTIL GET THE DESIRED ANGLE, THEN TIGHTEN THE
REAR FITTER BOLTS TO SECURE THE LUMINAIRE.

TERMINAL BLOCK:

RECOMMENDED TORQUE FOR SCREWS 35 IN-LBS.

STANDARD MOUNTING

:

LOOSEN (DO NOT REMOVE) THE FITTER BOLTS. LIFT THE
LUMINAIRE INTO POSITION IN FRONT OF THE MAST ARM SUCH 
THAT THE MAST ARM ENTERS THROUGH THE OPENING AT THE 
REAR OF THE LUMINAIRE AND BETWEEN THE FITTER BRACKET 
AND THE LUMINAIRE HOUSING. TIGHTEN FITTER BOLTS 
TO 

10-12 FT-LBS

.