INSTALLATION INSTRUCTIONS
POST TOP LUMINAIRE 247 SERIES & TCL FULL CUTOFF (FC)
American Electric Lighting a division of Acuity Lighting Group, Inc. Granville, OH
DRAWING NO. A72084 REV -- (FRONT)
©2008 ACUITY LIGHTING GROUP, INC.
PART NUMBER 057-71-72084
OPENING & CLOSING THE HOOD:
OPENING & CLOSING THE HOOD:
1. UNSCREW THE CAPTIVE SCREW LOCATED ON TOP OF THE
1. UNSCREW THE CAPTIVE SCREW LOCATED ON TOP OF THE
COVER.
COVER.
2. REMOVE COVER AND DISCONNECT MOLEX CONNECTIONS.
2. REMOVE COVER AND DISCONNECT MOLEX CONNECTIONS.
NOTE: CHECK TO INSURE THAT THE WIRES ARE NOT PINCHED
NOTE: CHECK TO INSURE THAT THE WIRES ARE NOT PINCHED
AGAINST THE CASTING DURING RE-INSTALLATION OF THE
AGAINST THE CASTING DURING RE-INSTALLATION OF THE
COVER.
COVER.
FULL CUTOFF COVER REMOVAL & INSTALLATION:
FULL CUTOFF COVER REMOVAL & INSTALLATION:
11.. TO OPEN THE FIXTURE HOOD, LOCATE THE CLOSURE SCREW
TO OPEN THE FIXTURE HOOD, LOCATE THE CLOSURE SCREW
LOCATED ON THE STREET SIDE OF THE FIXTURE. (SEE
LOCATED ON THE STREET SIDE OF THE FIXTURE. (SEE
FIGURE 1.)
FIGURE 1.)
2. UNSCREW THE CAPTIVE CLOSURE SCREW. YOU WILL
2. UNSCREW THE CAPTIVE CLOSURE SCREW. YOU WILL
KNOW
KNOW T
THE SCREW
HE SCREW IS
IS COMPLETELY DISENGAGED FROM
COMPLETELY DISENGAGED FROM
THE HOOD
THE HOOD WHEN
WHEN THE SCREW CAN MOVE FREELY UP AND
THE SCREW CAN MOVE FREELY UP AND
DOWN.
DOWN.
3. OPEN THE HOOD.
3. OPEN THE HOOD.
4. TO CLOSE THE FIXTURE, SIMPLY CLOSE THE
4. TO CLOSE THE FIXTURE, SIMPLY CLOSE THE HOOD AND RE-
HOOD AND RE-
TIGHTEN THE CAPTIVE CLOSURE SCREW.
TIGHTEN THE CAPTIVE CLOSURE SCREW.
NOTE FOR OPTIONAL
NOTE FOR OPTIONAL TRIGGER LATCH: TO OPEN THE UNIT
TRIGGER LATCH: TO OPEN THE UNIT
SIMPLY PULL
SIMPLY PULL TRIGGER SIMULTANEOUSLY WITH YOU
TRIGGER SIMULTANEOUSLY WITH YOUR
R INDEX
INDEX
FINGER WHILE
FINGER WHILE PUSHING UP ON THE HOOD WITH YOUR
PUSHING UP ON THE HOOD WITH YOUR THUMBS.
THUMBS.
CLOSE THE UNIT BY
CLOSE THE UNIT BY CLOSING THE HOOD AND PRESSING
CLOSING THE HOOD AND PRESSING DOWN
DOWN
UNTIL THE TRIGGER LATCH ENGAGE.
UNTIL THE TRIGGER LATCH ENGAGE.
DISCONNECT POWER BEFORE RELAMPING OR WIRING THE FIXTURE.
HOUSING MUST BE GROUNDED TO REDUCE POTENTIAL OF ELECTRICAL SHOCK
READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION
WARNING
!
TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL
APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES. FOR CODE INTERPRETATION,
CONSULT LOCAL CODE AUTHORITY
RISK OF FIRE. PRODUCT FOR OUTDOOR INSTALLATION AND USE ONLY.
WARNING
CAUTION
!
!
CLOSED HOOD - STREE
CLOSED HOOD - STREETT SIDE VIEW
SIDE VIEW
FIGURE 1
FIGURE 1
FIGURE 2
FIGURE 2
OPEN HOOD - TOP VIEW
OPEN HOOD - TOP VIEW
LOWER
LOWER
HOUSING
HOUSING
COVER
COVER
CAPTIVE
CAPTIVE
SCREW FOR
SCREW FOR
COVER
COVER
CUPOLA CAP
CUPOLA CAP
CUPOLA BASE
CUPOLA BASE
CUPOLA LENS
CUPOLA LENS
ADJUST PHOTO-
ADJUST PHOTO-
CONTROL BY LIFTING
CONTROL BY LIFTING
& TURNING CUPOLA
& TURNING CUPOLA
SIMULTANEOUSLY
SIMULTANEOUSLY
HOOD
HOOD
CLOSURE
CLOSURE
SCREW
SCREW
BOSS
BOSS
LOWER HOUSING
LOWER HOUSING
MIN POLE OD 2.375”
MIN POLE OD 2.375”
MAX POLE OD 3”
MAX POLE OD 3”
COVER
COVER
LAMP SOCKET
LAMP SOCKET
LOCATED WITHIN
LOCATED WITHIN
HOOD
HOOD
SET SCREWS (3)
SET SCREWS (3)
LADDER REST (2)
LADDER REST (2)
-OPTIONAL-
-OPTIONAL-
NEMA
NEMA
LABEL HERE
LABEL HERE
-OPTIONAL-
-OPTIONAL-
TRIGGER
TRIGGER
LATCH
LATCH
-OPTIONAL-
-OPTIONAL-