background image

Operator’s Guide for Rugged-UPS

TM 

1252 Series 

 
 
 

91-0120 Rev. B                 1 

 

© Acumentrics Corporation 2007-2008                         

 

 

 

 
 
 
 
 
 

1252 Rugged-UPS

 Series 

 
 
 
 

 

 
 

 

 

Summary of Contents for Rugged-UPS 1252 Series

Page 1: ...Operator s Guide for Rugged UPSTM 1252 Series 91 0120 Rev B 1 Acumentrics Corporation 2007 2008 1252 Rugged UPS Series...

Page 2: ...ne if additional product information updates are available The latest revision of the manual is also available at www acumentrics com Rugged UPS is a registered trademark of Acumentrics Corporation Co...

Page 3: ...Panel Rugged UPS 14 Rugged UPS Series Model Numbers and Options 14 Acumentrics Part Numbering System 14 Setup 15 SNMP Capability and Operation 15 Start Up 20 Extended Run Modules 20 Operation 21 Reset...

Page 4: ...Operator s Guide for Rugged UPSTM 1252 Series 91 0120 Rev B 4 Acumentrics Corporation 2007 2008 Inspection 29 Cleaning 29 Troubleshooting Procedures 29 END 31...

Page 5: ...ile sealing electronic components from the damaging effects of moisture airborne particles and other contaminates in the operating environment The Rugged UPS 1252 is an ON LINE Power Factor Corrected...

Page 6: ...s Do NOT obstruct the air intake in the front of the unit or the exhaust outlet at the rear of the Rugged UPS 1252 Sufficient airflow through the Rugged UPS is vital to its operation This UPS has an i...

Page 7: ...for AC Input optional DC Input AC Output optional DC Output with Battery Pack ACG1252R 18B Features options that are present in this manual that do NOT correspond with your device should be disregarde...

Page 8: ...nearby personnel ATTENTION Refer to the Operator s Guide for more information This symbol is intended to alert the user to the presence of important operating and maintenance instructions accompanying...

Page 9: ...ance and packaging the equipment securely to avoid shipping damage using the original packaging If this packaging is no longer available Buyer shall contact the Customer Service Department for instruc...

Page 10: ...ecifications Continuous Output Power 1250 VA 1000W AC Output Voltage 115 VAC 5 AC Output Frequency 60Hz 5 AC Output Waveform Sinusoidal Total Harmonic Distortion 1 5 with resistive load Environmental...

Page 11: ...diagnostic tests whenever the product is initially turned ON and periodically during operation During operation the Overtemp and or Overload indicators will illuminate if a fault is detected If this o...

Page 12: ...for at least 5 seconds to supply power to the Rugged UPS and enable the audible alarms Briefly hold the switch in the OFF position to turn the Rugged UPS off To disable the audible alarm briefly hold...

Page 13: ...tion to indicate the operating point is close to tolerance This indicator is NOT illuminated when the AC source drops below 80 VAC causing the Rugged UPS to switch to external DC If external DC is una...

Page 14: ...nector used by the manufacturer to program units The AC Input Breaker will trip when the current exceeds the UPS s capacity Refer to the Rear Panel photo and callouts below Rugged UPS Series Model Num...

Page 15: ...of a 10 100 Base T network interface using a standard RJ45 connector SNMP v3 protocol is supported with DHCP enabled The interface card has its own MAC address which is included with the documentatio...

Page 16: ...mentations Read upsObjects 1 upsIdent 1 upsIdentName 5 String A string identifying the UPS Read upsObjects 1 upsIdent 1 upsIdentAttachedDevices 6 String A string identifying the devices attached to th...

Page 17: ...ry voltage Read upsObjects 1 upsBattery 2 upsBatteryTemperature 7 int The ambient temperature at or near the UPS Battery casing Read upsObjects 1 upsInput 3 upsInputLineBads 1 int A count of the numbe...

Page 18: ...psAlarmTable 2 upsAlarmEntry 1 upsAlarmTime 3 Stamp The value of sysUpTime when the alarm condition was detected If the alarm condition was detected at the time of agent startup and presumably existed...

Page 19: ...wer is lost Read upsObjects 1 upsAlarm 6 upsWellKnownAlarms 3 upsAlarmTempBad 5 OID A temperature is out of tolerance Read upsObjects 1 upsAlarm 6 upsWellKnownAlarms 3 upsAlarmInputBad 6 OID An input...

Page 20: ...are absolutely necessary The On Internal DC indicator will be illuminated Monitor the battery status via the Battery Status indicators Indicators identify the present capacity of the battery pack and...

Page 21: ...ower is unavailable The internal battery pack allows for short term power backup in case of loss of external power which allows the user to shut down the system being powered in an orderly manner Sinc...

Page 22: ...aterials from storage and repackage the equipment reversing the sequence of instructions used for unpacking Follow standard shipping procedures for your organization Operation under extreme heat In ho...

Page 23: ...e unit and are opto isolated and driven by RS 232 transceivers The simple signal mode allows remote turn on off by the user supplying logic high true levels to the pins listed in table 1 This can be a...

Page 24: ...urned Please note that the commands are case sensitive The first command you must enter to start is G this puts the unit into smart mode You will also need the following information Baud rate 2400 Dat...

Page 25: ...gged UPSTM 1252 Series 91 0120 Rev B 25 Acumentrics Corporation 2007 2008 Legend Signifies Pin Signifies Pin socket AC Input Pin Out Functionality Plug Part Number MS3476W14 4S A B D C To line To Grou...

Page 26: ...oration 2007 2008 AC Output Pin Out Functionality Warning DO NOT USE THIS CABLE IN A 230VAC APPLICATION Plug Part Number MS3476W14 4P Optional DC Input Pin Out Functionality Plug Part Number CA3102E20...

Page 27: ...on 2007 2008 Optional DC Output Pin Out Functionality Plug Part Number MS3476L14 04P Optional Extended Run Pin Out Functionality Plug Part Number CA3102E20 14SBF80 A D B C Not Used Not Used Black Nega...

Page 28: ...Supplementary Recharge Intervals Storage Temperature Recharge Interval Below 20 C 68 F Every six months Between 20 C and 30 C 68 F and 86 F Every three months Over 30 C 86 F Storage to be avoided The...

Page 29: ...e g paper towels on the device Troubleshooting Procedures The following paragraphs explain the Troubleshooting Procedures used in this Section and list all unit level troubleshooting categories and ar...

Page 30: ...erloading UPS Flip the Main Power Switch to the ON position 6 Audible alarm continuously sounds with the Overtemp indicator illuminated UPS internal heat sink temperature is critically high Ensure UPS...

Page 31: ...Operator s Guide for Rugged UPSTM 1252 Series 91 0120 Rev B 31 Acumentrics Corporation 2007 2008 END...

Reviews: