Instruction Manual

 

 

ADEL system srl

 Via L. Barchi 9/B, 42100 Reggio Emilia  (Italy) – Tel. ++39-0522-345518 

Fax. ++39-0522-345551 – Internet: www.adelsystem.com – e-mail: info@adelsystem.it 

 

  

CBI123A_R8 Eng.doc 

CBI123A – CBI123A/S – CBI123ARJ 

Intelligent Battery Charger 

Thank you for having chosen one of our products for your work. We are certain that it will give the utmost satisfaction and be a notable 

help on the job. 

General Description:  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Application 

CBI battery charger is a range of microprocessor-power supplies witch correctly charge sealed lead-acid batteries at all time 
maximizing performance and life span. 
Charge the battery in multi-stage principle, Fast and Trickle and automatically the device, check the battery efficiency in a lifetime to 
prevent any risk of damage to the battery and allow leaving the charger permanently connected. Before begin the operations of 
installation consult the manual. 

Mains Characteristic 

 

Nominal Input Voltage: 115 - 230 Vac 

 

OUTPUT 1: for connection to Battery  

 

OUTPUT 2: for connection to Load   

 

Fast and trickle battery charge In according to DIN 41773 

 

Signaling: replace battery, low battery, mains or buffering 

 

Overload and short circuit protections 

 

Safety isolation in according with EN 60950 

 

Output 12 Vdc 6 A  50° C also without mains 

 

Degree of protection IP20 

 

Rail DIN mounting 

Vac Input 

Mains or  
Backup 

OUTPUT N°2 

Load Vdc Output 

Charging Level 

 

 

OUTPUT N°1 

Battery module 

Low Battery or 
Battery replacement 
 

Battery Type  
Configuration Jumper 

Monitor Led 

Auxiliary 

Output 

(CBIXXX/ARJ)

 