00 

 

 

 

 
 
 
 
 
 
 

Instruction manual 

Industrial router & firewall 
IRF3000 series 

 
 
 
 

 

Translation of the original 

instruction manual  

Version 1.1 

 

Updated 2023-01-11

 

Summary of Contents for IRF3000 Series

Page 1: ...00 Instruction manual Industrial router firewall IRF3000 series Translation of the original instruction manual Version 1 1 Updated 2023 01 11 ...

Page 2: ... 10 3 1 Safety instructions 11 3 2 Operating location 11 3 3 Damage due to improper use 11 3 4 Warranty repairs 12 3 5 Intended use 12 3 6 Improper use 12 3 7 Safety instructions 12 3 8 Safety instructions on mobile radio 13 3 9 Calculation example for the transmission power EIRP 14 3 10 Notes on using the device according to UL approval 15 4 Introduction 16 4 1 Equipment versions 16 4 2 Event log...

Page 3: ...rt card reader and slot for SIM card 24 7 Commissioning 25 7 1 Connecting the device to a laptop or PC 25 7 2 Configuration of the network adapter of the PC 25 7 3 Calling up the device web interface 26 7 4 Front LEDs 27 7 5 Operating mode related LED status displays 28 7 5 1 Boot up 28 7 5 2 Resetting to default settings 28 7 5 3 Firmware update 28 8 Technical data 29 9 Service support 30 9 1 ADS...

Page 4: ...r basic understanding and may differ from the actual design The operator operating company is independently responsible for compliance with and observance of any subsequently introduced technical innovations or new legal requirements as well as for all usual obligations of the operator operating company The original version of this instruction manual was written in German All non German versions o...

Page 5: ...ents are decisive to device setup and operation This instruction manual contains information for installation commissioning and operation of the device along with technical data of the device hardware Technical data sheet see download area Website You can download drivers software user manuals leaflets and flyers from the Download area of our website www ads tec com ...

Page 6: ... hazard Source of hazard Measures to prevent hazard 2 2 Graduation of risk level The signal word classifies the hazard Instructions for preventing the hazard are identified by an arrow 2 3 Explanation of used symbols DANGER Indicates an imminent danger If not avoided death or severe injury will result WARNING Indicates a possible danger If not avoided death or severe injury could result CAUTION In...

Page 7: ...be returned to the point of sale or a disposal system Label on electrical and electronic devices Electrical and electronic devices must not be disposed of with household waste but must rather be taken to a collection point for waste electrical equipment Such a collection point is generally operated by public waste management authorities i e by municipalities Symbol for the protective earth connect...

Page 8: ...d party trademarks used are hereby acknowledged In the case of infringement of trademark rights ADS TEC reserves the right to exercise all rights 2 7 Copyright This instruction manual is protected by copyright For the authorised user simple usage rights are granted within the scope of the intent of the contract Any modified use or exploitation of the provided content particularly duplication modif...

Page 9: ... cables used for device connection must also be compliant with these requirements It is therefore necessary to employ BUS and LAN cables with shielded connectors and these must be installed as per the instructions contained in the instruction manual Devices with FCC marking on the type plate Compliance with the requirements of the FCC USA Class A digital device This device has been tested and foun...

Page 10: ...to prevent electrostatic discharges on components If the device is opened up by an unauthorised person the user may be subject to hazards and the warranty is invalidated General information Installation commissioning and operation may only be performed by qualified and trained personnel The safety instructions and the instruction manual are to be observed by all persons who work with the device At...

Page 11: ...onmental conditions are maintained at all times Use in non specified environments i e on board ships in explosive atmospheres or at extreme elevations is prohibited See also chapter 8 Technical data ATTENTION Damage caused by condensation To prevent short circuits and malfunctions caused by the formation of water condensate the device may only be turned on after it has reached the specified ambien...

Page 12: ...nufacturer s declaration are necessary e g applications with explosion hazard medical technology shipping industry The device must not be put into operation in the case of transport damage or nonconformity with the specifications and if necessary must be taken out of operation in the case of changing conditions In the case of improper use ADS TEC shall not accept responsibility or liability for in...

Page 13: ...tentional startup WARNING Communication via wireless connections cannot be guaranteed The device must not be used for applications in which people could be injured or objects damaged due to interference of the wireless connection WARNING Risk of lightning strikes if the antenna is installed in an exposed position Check whether lightning protection is required at the installation location protectio...

Page 14: ...nical qualifications Per the requirements of the U S Federal Communications Commission FCC and the Canadian ISED Industry Canada the antenna gain including power losses must not exceed the following values when operating in North America LTE Band 2 1850 1910 MHz 6 dBi Band 4 1710 1755 MHz 6 dBi Band 5 824 849 MHz 6 dBi Band 7 2500 2570 MHz 9 dBi Band 12 699 716 MHz 6 dBi Band 13 777 787 MHz 6 dBi ...

Page 15: ...or devices with a UL marking on the type plate the following applies Indoor use only The communication cables may only be installed inside a building or a maximum of 42 7 m 140 feet outside buildings The device contains an internal fuse at the voltage input This fuse and all other internal components must not be replaced by service personnel but only by the manufacturer ...

Page 16: ... 4G LTE optional GPS GNSS Digital I Os IRF34x1 4 x RJ45 EU or EMEA US 2 I 1 O IRF38x1 8 x RJ45 x 5 I 4 O 4 2 Event log If the firewall is not disconnected from the power supply an event log saves all events The event log can be read out both locally and via a central syslog server 4 3 Mobile radio modem optional The integrated LTE modem enables mobile radio connections 4 4 Scope of delivery Please...

Page 17: ...d under the following conditions Failure to observe any one of these conditions will invalidate the warranty of the device ADS TEC cannot be held liable for any damages arising from improper use and handling See also chapter 8 Technical data Ambient temperature in operation 30 70 C for storage 40 85 C Humidity in operation 5 90 without condensation for storage 5 90 without condensation ...

Page 18: ...IRF3000 series Instruction manual v1 1 18 ads tec Industrial IT GmbH Heinrich Hertz Str 1 72622 Nürtingen Germany 5 Installation 5 1 External device dimensions IRF34x1 ...

Page 19: ...IRF3000 series Instruction manual v1 1 19 ads tec Industrial IT GmbH Heinrich Hertz Str 1 72622 Nürtingen Germany 5 2 External device dimensions IRF38x1 ...

Page 20: ...t rail and remove the screwdriver 3 The top hat rail locking mechanism springs back to its original position 4 Check that the IRF is seated securely on the top hat rail To release the device from the top hat rail proceed in the reverse order When removing take care not to damage the top hat rail adapter of the device 5 4 Optional accessory Attaching the VESA holder Screw the mounting plate directl...

Page 21: ...Heinrich Hertz Str 1 72622 Nürtingen Germany 5 5 Optional Attaching antennas Screw the mobile communications antennas to the antenna connections WWAN AUX MAIN directly or via an SMA extension cable IRF38 only Screw the SMA cable of the GPS antenna to the GNSS connection ...

Page 22: ...o IEC 60950 1 For devices with UL Certification NEC Class 2 Voltage 24 VDC 20 Short circuit current 8 A Devices with UL certification Underwriter Laboratories USA For the power supply of the device a power adapter acc to NEC Class 2 must be used LPS Limited Power Source Only use copper conductors to connect the power supply Schematic diagram for the wiring of digital input no 1 Recommendation for ...

Page 23: ...ial common for the data signals D Inverted data signal D Non inverted data signal 6 3 Digital I O 2 The digital I O 2 are electrically isolated from the power supply of the device Pin Signal V Power supply 24 VDC 20 DI2 Digital input 2 DO2 Digital output 2 GND Reference potential Schematic diagram 6 4 Digital I O 3 5 These electrically isolated inputs and outputs are only available with IRF38 Pin ...

Page 24: ...ust be inserted into the top slot SC SIM2 A microSD card with up to 2048 GB can be inserted into the left slot as a memory expansion Insert the cards the right way round as shown in the figure The configuration data of a device can be stored on the smart card If service is required the saved configuration can be transferred to the new device The setup procedure does not need to be repeated Complex...

Page 25: ...twork adapter of the PC Recommendation for use The procedure described in the following was prepared using the Microsoft Windows operating system as an example If you are using another operating system the paths and properties described here may vary On your PC laptop Open the properties of your network adapter used for establishing the connection and enter the following IP address 192 168 0 100 T...

Page 26: ...ddress and then confirm with Enter http 192 168 0 254 Once the IP address has been entered with success the login prompt appears The default settings are User name admin Password admin Confirm your entries by clicking on OK The device web interface then appears Follow the instructions of the commissioning wizard Hint If you cannot establish a connection check the proxy and local firewall settings ...

Page 27: ...he device is ready for operation STAT Status The device is not supplied with voltage Error during the boot up process recovery image VPN No VPN tunnel is active The tunnel activated via VPN key is active WWAN No mobile radio connection active Network search 1 Hz Login declined 2 Hz Firmware update of the radio module 5 Hz Logged in offline Logged in standby dial on demand Logged in online Legend L...

Page 28: ...to the boot up process and held down for approx 10 seconds during the boot up process The PWR LED flashes rapidly while resetting to factory settings As soon as the PWR LED illuminates constantly it is possible to access the web interface 7 5 3 Firmware update A firmware update can be performed via the web interface The PWR LED flashes rapidly during a firmware update of the firewall The actual up...

Page 29: ...tal inputs and outputs I O IRF34 2I 1O IRF38 5I 4O VPN Big LinX OpenVPN IPSec Operating modes IP router two subnets IP router extended up to 8 subnets Transparent Bridge Mobile WWAN Optional EU or EMEA US Dimensions See dimensional drawings in chapter 5 Protection class IP20 tested by ADS TEC not evaluated by UL Overvoltage Category I as per DIN EN 60664 1 max 1500 V Pollution Degree 2 as per IEC ...

Page 30: ...se specific configurations and software installations please contact them as ads tec will not be able to answer such questions ADS TEC does not provide support services for any device that was not purchased directly from ADS TEC In this case maintenance and support is provided by the partner company 9 1 ADS TEC support The ADS TEC support team is available for inquiries from direct customers betwe...