background image

Stand:31.10.2014 

 

 

User Manual 

Industrial PCs 
OPC6012/6015

 

 

 

 

 

 

 

Version 

2.0

 

Summary of Contents for OPC6012

Page 1: ...Stand 31 10 2014 User Manual Industrial PCs OPC6012 6015 Version 2 0 ...

Page 2: ...Industrial PCs OPC6012 6015 2 ads tec GmbH Heinrich Hertz Str 1 D 72622 Nürtingen Product Portfolio Copyright ads tec GmbH Heinrich Hertz Str 1 D 72622 Nürtingen Germany ...

Page 3: ...Operating instructions 10 2 1 Operating location 10 2 2 Damage due to improper use 10 2 3 Warranty repair 10 2 4 Treatment and disposal of lithium batteries 11 2 5 Notes on safety 12 3 Mounting 13 3 1 External Device Dimensions for OPC6012 13 3 1 Installation Layout for OPC6012 14 3 2 External Device Dimensions for OPC6015 15 3 3 Installation Layout for OPC6015 16 4 Commissioning 17 4 1 Available ...

Page 4: ...SD 28 7 2 External drives 28 8 Software driver installation 29 8 1 Installing the operating system 29 8 2 Touch screen driver installation 30 8 3 Configuration Center 31 8 4 Automatic brightness adaptation 32 8 5 USB Lock function 33 8 6 ON OFF pushbutton configuration 34 8 7 Exemplary RFID application 35 8 8 Soft keyboard 36 8 9 Screen Mob 36 8 10 Soft keyboard installation 37 9 Technical details...

Page 5: ... services in the area of automation data and system technology ads tec puts entire solutions for automation into practice from the planning to the commissioning and has particularly specialised in manipulation and material manipulation technology The Data Technology division develops and manufactures PC based solutions and holds a wide range of industrial PCs thin clients and embedded systems avai...

Page 6: ...vers and user manuals Note The service CD menu automatically starts if the autostart option for removable media is activated The service CD was created by using Adobe Flash The service CD menu is even available if the Flash Player is not installed Pos 3 D atentechni k Allgemei ne Hinweise Erl äuter ung zu den ver wendeten Symbolen Erläuter ung zu den verwendeten Symbolen 0 mod_1158752779484_6 doc ...

Page 7: ...hts of the intellectual property in terms of trademarks brand names and patents Windows Windows CE are registered trademarks of Microsoft Corp Intel Pentium Atom Core 2 are registered trademarks of Intel Corp IBM PS 2 and VGA are registered trademarks of IBM Corp CompactFlash is a registered trademark of the Compact Flash Association RITTAL is a registered trademark of Rittal Werk Rudolf Loh GmbH ...

Page 8: ...od_1263309234182_6 doc 6984 1 7 STANDARDS This device complies with the requirements and protective aims of the following EC regulations This device meets the test requirements for granting the CE sign according to the European test standards EN 61000 6 4 and EN 61000 6 2 This device complies with the test requirements in accordance with DIN EN 60950 VDE0805 IEC950 Safety of Information Technology...

Page 9: ... rotating mass storage medium hard disc etc and with an embedded operating system Windows CE 6 0 XP embedded for stationary use with a standard Ethernet Platform including a hard disc Equipped with a hard disc for stationary use e g in the manufacturing department using a standard operating system Pos 10 D atentechni k Allgemeine Hi nweise Li eferumfang Li eferumfang für VMT 60xx Serie 2 mod_12632...

Page 10: ...leads e g power leads interface cables may only be connected if the device is switched off in order to avoid damaging the device 2 1 OPERATING LOCATION The control system is designed for use inside a switching cabinet You must ensure compliance with the specified environmental conditions Using the device in non specified environments for example on board ships or in areas that might contain explos...

Page 11: ...osion should the wrong type of battery be used Warning Do not put lithium batteries into a fire do not solder on the cell body do not recharge them open them short circuit them do not reverse their polarity or heat them up over 100 C dispose of them properly and protect lithium batteries from direct sun light humidity and condensation Lithium batteries may only be replaced by the same type or by a...

Page 12: ...isconnected from the power supply and protected from accidental switch on Note Always adhere to the safety measures applicable when handling components at risk of being destructed by electrostatic discharges EN 61340 5 1 EN 61340 5 2 Pos 16 D atentechni k Montage Montageskizzen Außenabmessungen des Ger äts M ontageskizze Außenabmessungen für VMT 6012 1 mod_1226561943192_6 doc 4171 ...

Page 13: ...Industrial PCs OPC6012 6015 13 ads tec GmbH Heinrich Hertz Str 1 D 72622 Nürtingen 3 MOUNTING 3 1 EXTERNAL DEVICE DIMENSIONS FOR OPC6012 ...

Page 14: ... OPC6012 6015 14 ads tec GmbH Heinrich Hertz Str 1 D 72622 Nürtingen 3 1 INSTALLATION LAYOUT FOR OPC6012 Pos 17 echni k Inbetriebnahme Systemmer kmal e Inbetriebnahme für VMT 60xx Serie 2 mod_1263217785475_6 doc 6944 ...

Page 15: ...Industrial PCs OPC6012 6015 15 ads tec GmbH Heinrich Hertz Str 1 D 72622 Nürtingen 3 2 EXTERNAL DEVICE DIMENSIONS FOR OPC6015 ...

Page 16: ... OPC6012 6015 16 ads tec GmbH Heinrich Hertz Str 1 D 72622 Nürtingen 3 3 INSTALLATION LAYOUT FOR OPC6015 Pos 17 echni k Inbetriebnahme Systemmer kmal e Inbetriebnahme für VMT 60xx Serie 2 mod_1263217785475_6 doc 6944 ...

Page 17: ... in order to be able to use them 4 1 AVAILABLE INTERFACES Note If the case is connected with earth potential at the provided PE contact e g by connecting the PE contact with the device plug the electrical insulation is no longer given This also applies if the device is installed by using a metal retainer clip If you want to have the device electrically insulated from the power supply you have to u...

Page 18: ...audio output Level 1 Right mouse key function Level 2 The volume can be increased with devices equipped with an audio output Shift key SHIFT for activating the second keyboard level This key must be pressed simultaneously with the desired function key Note If the software keyboard is not installed only the functions for display settings and volume control are active The controller display will not...

Page 19: ...ivated which requires pressing two keys at the same time e g Alt F4 these keys have to be pushed one after another at the soft keyboard and the special keys Shift Alt and Ctrl must always be pushed first Due to differences in programming of a large variety of software we cannot ensure that the soft keyboard works properly with all software programmes When deactivating the soft keyboard the previou...

Page 20: ...TOUCH SCREEN The control system is equipped with a touch screen monitor The touch screen monitor is internally connected with the USB interface The driver software required for using the touch screen is integrated in the corresponding operating system or can alternatively be installed from the enclosed service CD Pos 23 D atentechni k Bedienung Status Anzeig en SYS LED SYS LED für VMT60xx Serie 2 ...

Page 21: ...The current consumption of this device depends on the equipment version e g if a heater or WLAN etc is installed Switch on current 7A 1ms Standby current consumption 0 25mA Regular operation 1 3A without heater without any additional load on the USB ports and without delivering the 5V supply for the scanner Note The power supply can be protected with a slow blow fuse of up to 4A Note The typical p...

Page 22: ...thod of installation that ensures appropriate insulation How to proceed if a PE system is used You must adhere to the following figure in order to ensure a correct installation of the PE system Pos 28 D atentechni k Schnittstell en Lautsprecher Lautsprecher für VMT 60xx 1 mod_1228482989111_6 doc 4247 ...

Page 23: ...rs Note The volume can be set up by using the device front keys When activating the described key combinations the volume level is modified If the soft keyboard is installed the system volume is additionally displayed by a display bar Pos 29 D atentechni k Schnittstell en USB Anschluss U SB Anschl uss für VMT 60xx 2 mod_1260457598122_6 doc 6860 ...

Page 24: ...h SSD is integrated a maximum of 7 USB mass storage devices can be connected Note The USB interfaces can be individually locked by using the Lock USB software tool USB CONNECTION IN THE FRONT PANEL One USB interface can be accessed from the front The interface is located under a plastic cover underneath the display The cover has a tab on the right hand side which is used for opening The plastic co...

Page 25: ... the monitor the use of the external keyboard for control purposes is limited The keyboard must be connected before switching the device on because the keyboard interface is initialised in the process of booting If the keyboard is plugged in while the device is running without having had the keyboard connected while booting it will not be functional Pos 31 D atentechni k Schnittstell en Netzwerkan...

Page 26: ...hould they not be installed on the device PIN NUMBER SIGNAL NAME 1 TX 2 TX 3 RX 4 NC 5 NC 6 RX 7 NC 8 NC Pos Datentechni k Schnittstell en Funknetzwer kkarte Funknetzwer kkarte für VMT Seri e 1 mod__6 doc 32600012463645135395856 Note The device has two separately integrated network controllers of the Realtek RTL 8111c Family PCIe Gigabit Ethernet type Note PXE booting is only possible by using the...

Page 27: ...5V power supply e g for operating a serial barcode scanner The COM 5V switch in the service slot of the device must be put in the ON position in order to use this function A subsequent restart of the computer might be required in order to properly activate this function PIN NUMBER SIGNAL NAME 1 DCD 2 RxD 3 TxD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI oder 5V DC max 1 A Note This interface is not electri...

Page 28: ...ne Laufwerke Exter ne Laufwer ke für OPC 5112 5115 5117 IPC 1100 CPC PLC OTC ITC VMT Serie 0 mod_1158926656205_6 doc 563 7 2 EXTERNAL DRIVES By default no drive for removable media CD floppy disk is integrated in the device Instead the system provides a USB interface to which an external drive can be connected In this case you d have to ensure that the used device is suitable for industrial enviro...

Page 29: ...by using one of the existing interfaces An external keyboard is required for installation 8 1 INSTALLING THE OPERATING SYSTEM The device does not have any integrated CD drive The installation of the operating system can therefore only be carried out by using the USB interface Procedure for installation The boot drive in the system Bios must be switched to USB in order to boot the device from the U...

Page 30: ...tions and acknowledge the licence terms and conditions Once the installer has completed the installation shut down the computer and restart it subsequently After restarting the touch screen monitor has to be calibrated If the driver does not automatically start activate the setup menu via Start Settings Control panel Elo Touchscreen Via the Calibration data menu calibrating the touch screen monito...

Page 31: ...which ads tec applications are installed on the device Additionally you can start any of these applications from the Configuration Center by double clicking on it INFORMATION In the Information section device specific data like the device type the firmware version and the serial number are listed The information you ll find here must be indicated whenever you need to contact the support department...

Page 32: ...her of both modes Note The threshold for Day Night mode has to be determined individually by the user for each device The day mode is enabled as soon as the ambient brightness is high enough The display brightness should be set to a slightly higher level than at night The night mode is enabled if the ambient brightness level is low The display brightness can be set to a lower level in this mode Th...

Page 33: ... be output in the event that a USB port is locked or not Additionally the locking process can be logged in the event log PASSWORD PROTECTION In order to avoid any unauthorised access to the USB Lock programme the settings made can be provided with password protection In this case the settings can only be modified if the password was entered correctly USB INTERFACES The desired USB ports can indivi...

Page 34: ...FF pushbutton configuration allows to change the behaviour of the ON OFF pushbutton REGULAR MODE The ON OFF pushbutton switched the device on and off SECURE MODE The ON OFF pushbutton only switches the device on The switch off function is disabled Note If the secure mode is used the device can only be shut down by the software ...

Page 35: ...ngen 8 7 EXEMPLARY RFID APPLICATION The exemplary RFID application was developed in order to test the function of the RFID reader Note Function only for devices with RFID possible Note In the Interfaces section of the manual you can find more information about the topic of RFIDs ...

Page 36: ...be adapted All changes must be confirmed by pushing the Save button 8 9 SCREEN MOB The Screen Mob application was developed in order to disable the touch screen of the device for a certain period of time This function can be used for cleaning the touch screen Pos 39 D atentechni k Softwar e Trei ber Install ati on Softkeyboar d Softkeytastatur für alle Ger ät ohne i nternes Laufwer k CD D VD 0 mod...

Page 37: ...ector of external drive at the device Switch on PC insert driver CD into drive after booting Start installer from the service CD Follow on screen instructions install the driver select the language and confirm the restart of the computer Note You can make further changes to the basic settings of the soft keyboard if required More information about this topic you ll find in the Readme file in the i...

Page 38: ...15W chipset incl integrated graphic controller Graphic memory max 8 MB shared Mass storage 2 x Flash SSD over interal USB Connection 1 x Flash SSD over interal USB Connection 2 5 Automotive Harddisk 40 GB UDMA 2 5 SSD PATA 2 GB Interfaces COM 1 RS232 connectable 5V power supply for scanner 1 x PS 2 Mouse Keyboard 2 x USB 2 0 1 x USB 2 0 in Front panel disconnectable Network 2 x Ethernet 10 100 100...

Page 39: ...ns and software installations they can only be answered by the system manufacturer For devices not directly purchased from ads tec we don t deliver any support The support is delivered by our associate companies in these cases 10 1 ADS TEC SUPPORT The ads tec support team is available for direct clients from Monday to Friday from 08 30 AM to 05 00 PM using the following phone number Phone 49 0 702...

Page 40: ...Industrial PCs OPC6012 6015 40 ads tec GmbH Heinrich Hertz Str 1 D 72622 Nürtingen 11 CE CONFORMITY DECLARATION Glossar y OPC6012 Glsar y ...

Page 41: ...Industrial PCs OPC6012 6015 41 ads tec GmbH Heinrich Hertz Str 1 D 72622 Nürtingen OPC6015 End of bill of materi als ...