ETHERNET SWITCH OPTION MODULE
P/N 1200766L1
For more detailed documentation, visit us online at
Quick Start Guide
Quick Start Guide, 61200766L1-13A, August 2002
Technical Support 1-888-4ADTRAN (1-888-423-8726)
Copyright
2002 ADTRAN, All Rights Reserved
S
PECIFICATIONS
Interface Type:
(8) 10BaseT/100BaseTX interfaces with auto MDI/MDIX
crossover on all interfaces
Flow Control:
Back-pressure flow control on all half-duplex interfaces
Pause-frame flow control on full-duplex interfaces
Environmental
Specifications:
Operating Temperature: 0°C to 45°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95% non-condensing
Compliance:
FCC Part 15, Class A
UL 60950, 3rd Edition
EN 60950
ETSI 300 386
N
ETWORK
C
ONNECTION
P
INOUT
Pin
Name
Description
1
TX1
Transmit Positive
2
TX2
Transmit Negative
3
RX1
Receive Positive
4, 5
UNUSED
—
6
RX2
Receive Negative
7, 8
UNUSED
—
500 Series
ETHERNET SWITCH
LINK/SPEED
1
2
4
3
5
6
8
7
I
NSTALLATION
I
NSTRUCTIONS
1.
Remove the cover plate from the appropriate option slot in the ATLAS
550 Base Unit.
2.
Slide the Ethernet Switch Option Module into the option slot until the
module is firmly positioned against the front of the chassis.
3.
Secure the thumbscrews at both edges of the module. Tighten with a
screwdriver.
4.
Connect the cables to the associated device(s).
5.
Complete installation of remaining modules and Base Unit as specified
in the Installation chapter of the ATLAS 550 System Manual.