background image

job

Aid 

2 M

D

ESCRIPTION

The GPON Indoor UPS Power Cable (Power Cable) connects an 
Indoor GPON ONT to the Uninterruptible Power Supply (UPS).

I

NSTALLATION

Before installing the equipment, inspect the Power Cable. If 
damage has occurred during shipping, file a claim with the 
carrier, and then contact ADTRAN Customer Support. For more 
information, refer to the warranty.

Required Tools

3/32 inch flat-head screw driver

Wire Cutter/Stripper

Installation Steps

To install the Power Cable, complete the following steps:

1. Route the Power Cable from the UPS to the ONT.
2. Strip approximately 1 inch of the outer insulation from the 

end of the Power Cable.

3. Strip approximately 1/4 inch of insulation from the ends of 

each wire in the Power Cable.

4. Remove the Power connector from the UPS.
5.  Refer to the table and figure below for the cable pinout.

Cable 

Connector

Cable

Connector 

Pin

Wire 

Color

Description

1

Red

+12V

2

White

ON Battery

3

Orange

Battery Missing

4

Green

Signal Return

5

Black

12V Return

6

Brown

Replace Battery

7

Blue

Low Battery

8

N/A

No Connect

1

5

2

6

3

7

4

8

GPON

Indoor UPS Power Cable

6. Using a small flat-head screwdriver, loosen the setscrew on 

the top of the UPS Power Connector.

7. Insert the bare wire into the opening on the UPS Power 

Connector.

8. While holding the wire in place, tighten the setscrew until 

the wire is secure.

9. Repeat steps 6 to 8 until all wires are connected.

10. Connect the Power Cable to the 

UPS

 port on the ONT.

11. Connect the UPS power connector to the UPS.

M

AINTENANCE

The Power Cable does not require routine hardware maintenance 
for normal operation. ADTRAN does not recommend that repairs 
be attempted in the field. Repair services may be obtained by 
returning the defective unit to ADTRAN. Refer to the warranty 
for further information.

ON/OFF

PWR

UPS

LAN1

LAN2

LAN

RESET

Product P/N: 1287402G1

Issue Date: January 2015

Document P/N: 61287402G1-22A

Documentation for ADTRAN Carrier Networks products is available for 

viewing and download directly from the ADTRAN Support Community 

website. 
Go to: 

https://supportforums.adtran.com/welcome

Registration is required.
ADTRAN offers training courses on our products, including customized 

training and courses taught at our facilities or at customer sites.
For inquiries, go to:

 http://adtran.com/training

The following documents provide additional information for this product:

Total Access 324 Indoor 3rd Generation SFU ONT Job Aid
Total Access 334 Indoor 3rd Generation SFU ONT with RF Job Aid