61190851L2-5, Issue 2

61190851L2-5C

Section 61190851L2-5C

Issue 3, May 2013

CLEI # T1TSRPHF _ _

HDSL 851 Remote Installation Kit

Installation and Maintenance

Trademarks:  Any brand names and product names included in this document are

trademarks, registered trademarks, or trade names of their respective holders.

1. GENERAL

This practice provides installation and operation

procedures for the ADTRAN HDSL 851 Remote

Installation Kit.  The HDSL 851 Remote Installation

Kit is designed for use with the ADTRAN HDSL 852

Central Office Installation Kit, part number

1190852L2.  

Figure 1

 is an illustration of the HDSL

Remote Installation Shelf.  This kit can house any

standard T200 or T400 card and thereby support any

number of technologies to include T1, HDSL,

HDSL2, DDS, ISDN, TR-DDS, TR-ISDN, FT1, and

others.  This practice is written around the HDSL

application.

Revision History

Issue 2 revises ordering guide tables.

Issue 3 removes the carrying case.

Features

The HDSL 851 Remote Installation Kit, part number

1190851L2, includes the following features:

• Compact construction installation unit.
• Optional adapter for 239/439 size repeaters.
• Span powered.
• Connections for local power.
• Bantam to alligator connections.

Adapter Insert

A separately purchased adapter insert configures the

T200/400 form factor to accommodate the following

mechanics:

• Insert T200/400 to 239/439 form factor

P/N 1190851L22

Figure 1.  HDSL 851 Remote Installation Shelf

TABLES

Table 1.

Line Units ................................................. 5

Table 2.

Specifications ........................................... 8

Table 3.

Ordering Guide for the Remote Shelf ...... 8

Table 4.

Ordering Guide for the CO Shelf ............. 8

FIGURES

Figure 1. HDSL 851 Remote Installation Shelf ...... 1

Figure 2. HDSL Circuit Simulation ........................ 2

Figure 3. Front Panel Features ................................ 3

Figure 4. Rear Panel Features.................................. 3

Figure 5. Test Cable ................................................ 5

Figure 6. Testing HDSL Live Units ........................ 5

Figure 7. Adding a Repeater to HDSL Circuit ........ 6

Figure 8. Accessing an HDSL Circuit from the

Remote End .............................................. 6

Figure 9. T1 BERT Testing of an HDSL Circuit .... 7

Figure 10. Adapter Insert Installation........................ 8

CONTENTS

1.

GENERAL.......................................................... 1

2.

OPERATION...................................................... 2

3.

TESTING............................................................ 5

4.

SPECIFICATIONS ............................................ 8

5.

MAINTENANCE ............................................... 9

6.

WARRANTY AND CUSTOMER SERVICE ... 9

CAUTION:

RISK OF ELECT

RICAL

SHOCK.  MAXI

MUM

VOLTAGES UP 

TO

-200 VDC MAY

 BE

PRESENT ON T

ELECOM

CIRCUITS.

1190851L2

HDSL 851 

REPEATER/

REMOTE

ESD

GND

RPTR. C.O.

CABLE PAIRS

RPTR. TO REM

OTE

CABLE PAIRS

LP1 LP2

LP1 LP2

REMOTE

CABLE PAIRS

DS1

LP1 LP2

LP1 LP2

RPTR

IN

OUT

Summary of Contents for HDSL 851

Page 1: ...ion unit Optional adapter for 239 439 size repeaters Span powered Connections for local power Bantam to alligator connections Adapter Insert A separately purchased adapter insert configures the T200 400 form factor to accommodate the following mechanics Insert T200 400 to 239 439 form factor P N 1190851L22 Figure 1 HDSL 851 Remote Installation Shelf TABLES Table 1 Line Units 5 Table 2 Specificatio...

Page 2: ...ge is noted file a claim with the carrier then notify ADTRAN See Warranty and Customer Service The Remote Installation Kit is shipped complete with remote shelf and dual bantam to alligator cables Front Panel Features The HDSL Remote Installation Kit front panel features remote and repeater unit slots four dual bantam jacks a repeater selection button and two ground lugs for ESD ground and earth g...

Page 3: ...ring is not available the unit can be locally powered by applying 48 Vdc to connectors on the back of the unit Preventing ESD Damage To prevent damage caused by electrostatic discharge ESD follow these precautions when using the HDSL Installation Kit 1 Install the ground cable between ground and the bottom ground lug on the front of the HDSL Installation Kit 2 When working with HDSL line units mak...

Page 4: ...L circuit 4 To remove an HTU R remove the patch cord connecting the line unit to the HDSL circuit Pull the ejector lever on the bottom of the HTU R or grasp the line unit by its front panel and gently pull it from the slot observing ESD precautions Installing Test Cables The HDSL Installation Kit is connected to the HDSL circuit by installing test cables between the installation kit s LP1 and LP2 ...

Page 5: ...01 L2 LBK ALM DSX DSL TX RX TX RX M O N E Q HTU CM AMI UFRM SF EN EN 1 2 3 4 5 CAUTION RISKOFELECTRICAL SHOCK MAXIMUM VOLTAGES UPTO 200 VDCMAYBE PRESENTONTELECOM CIRCUITS 1190852L2 HDSL852 COPOWER REMOTE LP1 LP2 DS1 TX RX ESD GND DSX 1 LBO B8ZS FRM ESF NIU LB DIS LB TIMEOUT DIS 533 399 266 133 0 EXT 1246001 L2 LBK ALM DSX DSL TX RX TX RX M O N E Q HTU CM AMI UFRM SF EN EN 1 2 3 4 5 Patch Cables CO...

Page 6: ...1190851L2 HDSL 851 REPEATER REM OTE ESD GND RPTR C O CA BLE P AIR S RPT R TOREMOTE CA BLEPA IRS LP1 LP2 LP1 LP2 REMOTE CA BLE PA IRS D S1 LP1 LP2 LP1 LP2 RPTR IN OUT To perform this procedure access to the cable span at a midpoint such as a cross connect must be obtained The steps are as follows WARNING On a live HDSL circuit potentially dangerous voltage may be present on the loop 1 and loop 2 si...

Page 7: ...the BERT tester s DS1 transmit jack must be connected to the installation kit s DS1 TX jack and the tester s DS1 receive jack to the installation kit s DS1 RX jack 2 Install a test cable to connect the HDSL Installation Kit to the HDSL circuit For an end to end test make the connections at both ends of the cable span Connect the HDSL Installation Kit LP1 signal jack to the loop 1 twisted pair Conn...

Page 8: ... 852 CO Shelf Table 4 provides a list of products for the CO Installation Kit Table 2 Specifications r e w o P e g a t l o V s p m A c d V 8 4 A 2 0 l a t n e m n o r i v n E e r u t a r e p m e t g n i t a r e p O e r u t a r e p m e t e g a r o t S C 0 5 o t 0 F 2 2 1 o t 2 3 C 0 7 o t 0 4 F 8 5 1 o t 0 4 l a c i s y h P n o i s n e m i D t h g i e W 5 h g i h 2 1 7 p e e d 2 1 6 e d i w 2 1 b l...

Page 9: ...ADTRAN Sales Pricing Availability 800 827 0807 ADTRAN Technical Support Pre sales Applications Post sales Technical Assistance 800 726 8663 Standard hours Monday Friday 7 a m 7 p m CST Emergency hours 7 days week 24 hours day ADTRAN Repair CAPS Return for Repair Upgrade 256 963 8722 Repair and Return Address Contact CAPS prior to returning equipment to ADTRAN ADTRAN Inc CAPS Department 901 Explore...

Page 10: ...C 5 2 L 1 5 8 0 9 1 1 6 3 e u s s I 5 2 L 1 5 8 0 9 1 1 6 0 1 ...

Reviews: