Quick Start Guide, 61700144G1-13B, September 2011
1
N
ET
V
ANTA
640 S
ERIES
1700144G1
4
Copyright © 2011 ADTRAN, Inc. All Rights Reserved.
G
ETTING
S
TARTED
Two configuration methods are available for your NetVanta 640 Series unit:
•
Web-based graphical user interface (GUI)
•
Command line interface (CLI)
The GUI lets you configure the main unit settings and provides online guidance and explanations for each
setting. However, using the ADTRAN Operating System (AOS) CLI may be necessary for more advanced
configurations.
A
CCESS
THE
GUI
You can access the GUI from any Web browser on your network by following these steps:
1.
Connect the unit to your PC, using an Ethernet cable connected to the
ETH 1
port on the front of the unit.
2.
Set your PC to obtain an IP address automatically using Dynamic Host Configuration Protocol (DHCP), or
change your PC to a fixed IP address of
10.10.10.2
. To change your PC’s IP address, or to set the PC to
use DHCP, navigate to
Computer
>
Control Panel
>
Network Connections
>
Local Area Connection
>
Properties
>
IP (TCP/IP)
and select either
Use this IP address
or
Obtain an IP address
automatically
(this means you are using DHCP). If you are specifying an IP address, enter these
parameters:
IP Address:
10.10.10.2
Subnet Mask:
255.255.255.0
Default Gateway:
10.10.10.1
You do not need to enter any domain naming system (DNS) server information. After the information is
entered, select
Ok
twice, and close the Network Connections dialog box. If you cannot change the PC’s
IP address, you will need to change the unit’s IP address using the CLI. (Refer to the next two sections for
instructions.)
3.
Enter the unit’s IP address in your browser’s address line. The default IP address is
10.10.10.1,
but if you
changed the unit’s IP address enter that address in the browser line.
4.
You will then be prompted for the user name and password (the default settings are
admin
and
password
).
5.
The initial GUI screen appears. You can access initial setup information by selecting
Config Wizard
from
the menu on the left.
A
CCESS
THE
CLI
Access the AOS CLI using the
CONSOLE
port or a Telnet session. To establish a connection to the unit’s
CONSOLE
port, you need the following items:
•
PC with VT100 terminal emulation software
•
Straight-through serial cable with a DB-9 (male) connector on one end and the appropriate interface for
your terminal or PC communication port on the other end
It is best to only use the Config Wizard for new installations because some existing
settings can be lost or reset when using this wizard.
You can find VT100 terminal emulation software on most PCs by navigating to
Start
>
Programs
>
Accessories
>
HyperTerminal
>
HyperTerminal
. When you have opened
a HyperTerminal session, enter the settings described in Step 4.
N
ET
V
ANTA
640 S
ERIES
D
EFAULTS
R
ESTORING
F
ACTORY
D
EFAULTS
On units that have a console port, you cannot restore the factory defaults, but must rather erase the device’s
configuration and then reconfigure the unit to operate correctly for your network. To erase the unit’s current
configuration, follow these steps:
1.
Access the unit’s CLI and enter
enable
at the
>
prompt.
2.
Enter
erase startup-config
at the
#
prompt. The device will have a blank configuration upon reboot.
3.
Enter
reload
at the
#
prompt to begin restarting the device. When prompted to save configuration, enter
no
. When prompted to reboot, enter
yes
.
4.
Upon reboot, you will have to reconfigure the unit using the
CONSOLE
port. Follow the steps outlined
here or in the technical note,
Accessing the Web Interface in AOS
(ADTRAN’s Knowledge Base article
1788) available online at
.
Feature
Default Value
IP Address
10.10.10.1
User Name
admin
Password
password
HTTP Server
Enabled
Event History
On
IP Routing
Enabled