THYRO-S

 

THYRISTOR-SCHALTER  Thyro-S 1S...H 1  Thyro-S 1S...H RL1
THYRISTOR-SWITCH 

Thyro-S 1S...H 1  Thyro-S 1S...H RL1

  

AUGUST 2015

          

8000029341 DE/EN - V7

Summary of Contents for Thyro-S 1S H 1 Series

Page 1: ...1 THYRO S THYRISTOR SCHALTER Thyro S 1S H 1 Thyro S 1S H RL1 THYRISTOR SWITCH Thyro S 1S H 1 Thyro S 1S H RL1 AUGUST 2015 8000029341 DE EN V7...

Page 2: ...2...

Page 3: ...1 THYRO S THYRISTOR SCHALTER Thyro S 1S H 1 Thyro S 1S H RL1 THYRISTOR SWITCH Thyro S 1S H 1 Thyro S 1S H RL1 AUGUST 2015 8000029341 DE EN V7...

Page 4: ...ice on the following hotline Advanced Energy Industries GmbH Emil Siepmann Stra e 32 D 59581 Warstein Tel 49 0 2902 763 558 www advanced energy com COPYRIGHT No part of these operating instructions ma...

Page 5: ...as follows the use of the product other than for the intended use the residual product risk as well as operating errors and their consequences The information given below must be understood in this r...

Page 6: ...planned reach the Thyristor switch or load On principle this can lead to the Thyristor switch or load being damagad TRANSPORT Thyristor switches are only to be transported in their original packaging...

Page 7: ...by a skilled electrician The electrical regulations which are locally valid are to be adhered to CAUTION The Thyristor switch contains dangerous voltages Repairs may only be carried out by qualified...

Page 8: ...itional indications using type S H RL1 17 2 4 1 Error indication relay K1 17 2 5 Additional monitoring using type S H RL1 17 2 5 1 Thyristor short circuit monitoring 17 2 5 2 Load monitoring undercurr...

Page 9: ...37 8 2 Commissioning 37 8 3 Service 37 8 4 Checklist 38 9 Type overview 39 9 1 Typ 1S H 1 39 9 2 Typ 1S H RL1 39 10 Technical data 40 11 Dimensional drawings 42 Dimensional drawing Thyro S 1S 16H 30H...

Page 10: ...Fig 6 Operation Thyro 1S H RL 1 29 Fig 7 User surface Thyro Tool Family 31 Fig 8 Connecting diagram Thyro S 1S H 1 33 Fig 9 Connecting diagram 2x Thyro S 1S H 1 34 Fig 10 Connecting diagram Thyro S 1...

Page 11: ...exactly to avoid damage or destruction of Thyro S or parts thereof REMARK This is where remarks on technical requirements and additional informa tion is given which the user must observe ACCIDENT PRE...

Page 12: ...ructions are available and observed operating conditions and specifications are observed protective installations are used maintenance personnel are immediately notified or Thyro S is imme diately put...

Page 13: ...on of use GUIDELINES The CE mark on the device confirms adherence to the general EC guidelines for 2006 95 EEC low voltage and for 2004 108 EEC electromagnetic compatibility if the instructions on ins...

Page 14: ...echnical changes within the present operating instructions without obligation to notification Advanced Energy is not obliged to update these operating instructions constantly LOSS OF WARRANTY Our supp...

Page 15: ...ever voltages or currents need to be controlled in processing technology With its good coupling ability to process and automation technology high control precision and simple handling Thyro S is also...

Page 16: ...tages 0 43 x Unom Load circuit monitoring Indication relay 1 3 TYPE KEY The type name of the thyristor switches is based on the construction of the power unit Thyro S 1S Thyristor switch with 1 phase...

Page 17: ...per mode default setting 1 2 every 2 mains full wave DC free 1 3 every 3 mains full wave DC free 1 5 every 5 mains full wave DC free 2 1 1 DIGITAL SET POINT INPUTS The Thyristor switch Thyro S is equi...

Page 18: ...NOTE The devices may only be operated up to the undervoltage limit if he electronics are supplied by an ext 24 V voltage If the undervoltage limit is undercut the pulse lock is activated and realy K1...

Page 19: ...ccurring in the controller or load circuit Indications are given via LED LOAD FAULT and via the K1 relay The device continues to run during errors as standard can be config ured using the Thyro Tool F...

Page 20: ...n the operating modes 1 2 1 3 and 1 5 The load monitoring is supplied with the default configuration OFF left stop R205 0 For all other configurations If the load current falls below the level set the...

Page 21: ...be used TAB 1 LOAD MONITORING NO OF PARALLEL LOAD RESIS TANCES E G NUMBER ILOAD NOM ITYPE CONTROLLER RESISTANCE INCREASE IN CASE OF FAULT RECOM MENDED SETTING FOR POTI R205 POTI REVOLU TIONS CA 1 100...

Page 22: ...rolled by Thyro S independently With 1 2 operation each 2 cycle is switched with 1 3 and 1 5 operation half cycles are switched with alternating polarity so that while switched on the load is supplied...

Page 23: ...l Family No special setting is necessary here Further information is contained in chapter 5 3 3 DIAGNOSIS STATUS INDICATION Faults can occur in the load circuit and in the controller itself or from th...

Page 24: ...limit On Off On only with H RL1 Faulty parameter flash value invalid On Flash fast Flash fast Undervoltage On On On Thyristor short circuit On Flash slow Flash slow only with S H RL1 LED STATUS Off L...

Page 25: ...e value with device types H RL 1 in the range of 15 to 10 If the mains voltage here is smaller than 15 then with these types the additional 24 V supply is needed The permitted frequency range of the m...

Page 26: ...c signal It can for example be gated by 24 V DC If a voltage of more than 3 V is available at this input then the Thyro S is switched on below 3 V it is switched off Between terminals X22 1 input and...

Page 27: ...cal Data Connector Data power circuit only for HF modules F1 integrated semi conduc tor fuse F2 1 6 A A D converter Connection for option bus module Refer to operation inst ructions of bus module e g...

Page 28: ...on to bus module TxD connection to bus module Bus module recognition Earth Pos power supply unstabilised usable as source for terminal 1 Control signal On 3 V L2 N mains connection synchronisation vol...

Page 29: ...27 4 7 BLOCK DIAGRAM 1S H RL1 In the block diagram the functions of type H RL1 are shown The central control element is a e controller FIG 4 BLOCK DIAGRAM...

Page 30: ...arth Pos power supply 15 35 V usable as source for terminal 1 Control signal ON 3 V 24 V additional control voltage input AC DC RM 3 5 24 V additional control voltage input AC DC L2 N mains connection...

Page 31: ...H RL1 LED GREEN ON LED GREEN Diagnosis LED RED LOAD FAULT Without function Thyro Tool Mode chapter 3 1 Operating mode chapter 3 1 Operating mode Load monitoring LOAD FAULT chapter 2 3 S1 4 S1 3 S1 2...

Page 32: ...ith one bus module e g Profibus DP Modbus RTU CANopen or DeviceNet The bus module connection configuration is identical for all available bus modules Further information can be obtained from the opera...

Page 33: ...ntroller is present see 5 2 This makes visual readings parameter viewing and fault diagnosis possible If Thyro S is not operated in Thyro Tool mode certain parameters can be changed In Thyro Tool mode...

Page 34: ...or Thyro P must be used Thyro S can be employed in single phase switch and in three phase switches which can be transposed to single phase switches e g star connections with MP conductor or N conduct...

Page 35: ...33 FIG 8 CONECTION DIAGRAM THYRO S 1S H 1...

Page 36: ...34 FIG 9 CONNECTING DIAGRAM 2X THYRO S 1S H 1...

Page 37: ...35 FIG 10 CONNECTING DIAGRAM THYRO S 1S H RL1...

Page 38: ...36 FIG 11 CONNECTING DIAGRAM 2X THYRO S 1S H RL1...

Page 39: ...ding to local electricity board regulations grounding screw for protective conductor connection on fastening adapter is provided The grounding also serves EMV devices Y capacitor 4 7 nF For Thyro S wi...

Page 40: ...power supply where applicable Supply available but no load current Check mains voltage Switching on signal digital set point X22 1 versus X22 3 3 Check load circuit for interruptions Check flashing L...

Page 41: ...RAW FUSE F1 DIMENSIONS IN MM KG 9 2 TYPE 1S H RL1 Thyristor switches with incorporated semiconductor system bus inter face additional 24 V d c a c control voltage supply relay indication and load curr...

Page 42: ...t setting 1 2 every 2 mains full wave DC free 1 3 every 3 mains full wave DC free 1 5 every 4 mains full wave DC free Digital set points inputs connection signals The Thyro S has 2 set point inputs Th...

Page 43: ...rew Conductor cross sect 16 A Lasche M4 Lasche M4 6 mm2 max 30 A Lasche M4 Lasche M4 6 mm2 max 45 A M 6 M 6 50 mm2 max 60 A M 6 M 6 50 mm2 max 100 A M 6 M 6 50 mm2 max 130 A M 8 M 10 95 120 mm2 170 A...

Page 44: ...42 11 DIMENSIONAL DRAWINGS THYRO S 1S 16H 30H THYRO S 1S 45H 60H...

Page 45: ...43 THYRO S 1S 100H THYRO S 1S 130H 170H...

Page 46: ...44 THYRO S 1S 280H...

Page 47: ...32 additionally required Order no 6000016474 RS232 data line Order no 8000019086 Adapter cable USB1 1 to RS 232 Order no 2 000 000 841 Bus module Profibus DP Order no 2 000 000 842 Bus module Modbus R...

Page 48: ...N ISO 9001 UL registration file no E 135074 with consideration to Canadian National Standard C 22 2 No 14 95 UL Markings Tightening torque in pound inches see Chapter 10 Technical data Use 75 C Copper...

Page 49: ...50 178 Tab 2 Air pressure 900 mbar 1000 m above NN Safe isolation up to 500 V mains voltage EN 50 178 Chap 3 Air and creeping distances according casing mains potential 5 5 mm to EN 50178 Tab 2 and 3...

Page 50: ......

Page 51: ......

Page 52: ......

Page 53: ...Advanced Energy Industries Inc All rights reserved Advanced Energy and Thyro S are trademarks of Advanced Energy Industries Inc World Headquarters 1625 Sharp Point Drive Fort Collins CO 80525 USA 970...

Page 54: ......