OVERVIEW

 

The  AND Call Button Kit (AND-BTN-
KIT-1)  includes  a  momentary  push 
button with wall plate.  The button 
connects  to  the  general  purpose 
input of an AND device. 

 

NOTE:

 LEGACY DEVICE 

COMPATIBILITY CONSIDERATION   

Older  devices  with  a  MAC  address 
less  than  20:46:F9:05:30:00  require 
an  AND-PIA-2  card  (AND-PIA-2D  for 
IPSIGNL-RWB  or  IPCDS-RWB)  to 
interface with the button, except for 
the  ZONEC2  which  can  directly 
connect to the button.  Contact AND 
tech  support  (

tech@anetd.com

)  for  

more 

information 

or 

help 

determining product compatibility. 

WIRING

 

Warning:  Remove  power  prior  to 
installation to avoid possible damage 
of components. 

 

Use 18 - 22 AWG stranded or solid 
core  wire  for  connection  between 
the  button  and  the  AND  device.  
Strip the device end of the wires to 
8mm.  Connect the wires to the two 
inputs  on  the  GPIO  0  terminal  of 
the device by pushing down on the 
terminal  tabs  and  inserting  the 
wires  into  the  terminal  holes.  
Polarity  of  the  wires  does  not 
matter.  Strip and connect wires at 
other end of run to screw terminals 
of  button.    To  trigger  the  input 
sensing, press the button. 

 

 

Summary of Contents for AND-BTN-KIT-1

Page 1: ...ith the button except for the ZONEC2 which can directly connect to the button Contact AND tech support tech anetd com for more information or help determining product compatibility WIRING Warning Remove power prior to installation to avoid possible damage of components Use 18 22 AWG stranded or solid core wire for connection between the button and the AND device Strip the device end of the wires t...

Page 2: ...rector y file and save the settings If using a configuration file add the following tag GPIO_callback url http 10 10 3 4 8089 directo ry file min_update_period_ms 250 3 Reboot the device In this example when the input changes state the device will execute an HTTP GET to 10 10 3 4 port 8089 of the following format parameters detailed below GET directory file address 2046f9 010203 gpinputid 0 state ...

Page 3: ...eckbox next to the device s with the monitored input in the Listen for trigger source list at the bottom of the screen 8 Fill out the remaining details of the Alert such as a scrolling message and audio file as well as the devices to receive the alert in the Output devices list if desired 9 Select OK to save the Alert IPClockWise will now respond to the input as configured PUSH TO TALK OPERATION Y...

Page 4: ...Push to Talk 1 parameter to the extension or SIP ID of the phone or third party device to call when pressing the button Save the settings If configuring the device using a configuration file add or modify the push_to_talk_ip1 parameter in the SIPConfig tag SIPConfig push_to_talk_ip1 2450 See related third party documentation for details on setting up a SIP extension on the AND device 2 Reboot the ...

Reviews: