background image

User Manual

ACP-1000MB

1U 19” Rackmount 
Industrial Chassis

Summary of Contents for ACP-1000MB

Page 1: ...User Manual ACP 1000MB 1U 19 Rackmount Industrial Chassis...

Page 2: ...rmission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable How ever Advantech Co Ltd assumes no responsibility for its use nor for any infringe ments of t...

Page 3: ...and current rating marked on the product 11 All cautions and warnings on the equipment should be noted 12 If the equipment is not used for a long time disconnect it from the power source to avoid bei...

Page 4: ...e harsh and demanding conditions typical of indus trial environments Whether your new Advantech equipment is destined for the labo ratory or the factory floor you can be assured that your product will...

Page 5: ...y available 3 If your product is diagnosed as defective obtain an RMA return merchandise authorization number from your dealer This allows us to process your return more quickly 4 Carefully pack the d...

Page 6: ...ACP 1000MB User Manual vi...

Page 7: ...3 1 LED indicator functions 10 3 2 Replacing the Cooling Fan 11 3 3 Replacing the Filter 11 Figure 3 1 Replacing the filter 11 3 4 Replacing the Power Supply 11 Chapter 4 Alarm Board 13 4 1 Alarm Boa...

Page 8: ...module 18 Table 4 12 CN1 CN2 Temperature sensor connector 19 Table 4 13 SW1 Thermal sensor I D setting 19 Appendix A Exploded Diagram 21 A 1 Exploded Diagram 22 Figure A 1 Exploded diagram 22 Appendi...

Page 9: ...pter 1 1 General Information This chapter provides general information about the ACP 1000MB Sections include Introduction Specifications Power Supply Options Environment Specifications Dimension Diagr...

Page 10: ...arm notification of system status This ultra thin server with 1U form factor delivers rack space optimization without sacrificing performance expandability serviceability or manageability 1 2 Specific...

Page 11: ...ange 5 V 16 A 3 3 V 14 A 12 V 9 A 12 V 0 7A 5 V 0 2 A 5 Vsb 1 5 A 5 V 2 A 12 V 1 A 5 V 0 1 A 12 V 0 1 A 5 Vsb 0 1 A UL TUV CB CCC 100 000 hours 25 C Table 1 2 Environmental specifications Environment...

Page 12: ...ACP 1000MB User Manual 4 1 5 Dimension Diagram Figure 1 1 Dimension diagram Unit mm inch...

Page 13: ...Chapter 2 2 System Setup This chapter introduces the instal lation process Sections include Installing the Motherboard Installing an Add on Card Installing Disk Drives...

Page 14: ...I O shielding onto the rear plate first Then fasten the motherboard onto the chassis 3 Return the card holder to its original position and fasten it 4 Connect the 20 pin or 24 pin ATX power connector...

Page 15: ...process is as follows 1 Remove the I O bracket attached to the rear plate of the chassis Insert an add on card into the slot on the riser card Figure 2 1 Installing add on card 2 4 Installing Disk Dr...

Page 16: ...power cable to IDE kit 4 To install the FDD remove the front cover of the 3 5 bay first Then insert the FDD into its proper location and secure it with the screws provided 5 To install the internal 3...

Page 17: ...Chapter 3 3 Operation This chapter introduces the sys tem operation information Sections include The front panel Replacing the cooling fan Replacing the filter Replacing the power supply...

Page 18: ...t side of the front panel indicate system health and activity Refer to Table 3 1 for the LED definition summary When the system power is on the power LED is always Green When the power LED is RED it i...

Page 19: ...eplace the filter periodically The filter is located on the front panel To remove and clean the filter simply unscrew the filter cover Then replace the filter with a new one Figure 3 1 Replacing the f...

Page 20: ...ACP 1000MB User Manual 12...

Page 21: ...hapter 4 4 Alarm Board This chapter introduces the alarm board and thermal sensor specifi cations Sections include Alarm Board Layout Alarm Board Specifications Thermal Sensor Sensor I D Number Settin...

Page 22: ...larms and LED indicators The alarm module sounds an audible alarm whenever 1 Any power supply module of the redundant power supply fails 2 One of the system cooling fans fails 3 The internal temperatu...

Page 23: ...ected from the motherboard Output Signals One LED board connector One buzzer output 4 2 1 Connectors Pin Definitions Table 4 1 CN1 Auxiliary external power connector standard mini 4 Pin power connecto...

Page 24: ...V signal Pin 13 N A Pin 6 HDD_1 Pin 14 3 3 V signal Pin 7 Power Good Pin 15 5 Vsb signal Pin 8 Power Fail Table 4 7 CN26 HDD LED connector Pin 1 HLED_ACT Pin 2 N A Table 4 8 FAN1 FAN7 Fan connectors P...

Page 25: ...OFF OFF 4 default OFF OFF ON OFF 5 ON OFF ON OFF 6 OFF ON ON OFF 7 ON ON ON OFF Note Connect the fan connectors in the correct sequence if two fans are set on SW1 the correct method is to connect the...

Page 26: ...chas sis see Figure 4 2 Figure 4 2 Thermal sensor location Refer to Figure 4 3 for a diagram of the thermal sensor module layout Figure 4 3 Thermal sensor module The default sensor I D number is 1 Use...

Page 27: ...sensor connector Pin 1 5 V Pin 3 T_SDAT Pin 2 T_SCLK Pin 4 GND Table 4 13 SW1 Thermal sensor I D setting Sensor I D No SW 1 1 SW 1 2 SW 1 3 SW 1 4 1 default OFF OFF OFF ON 2 OFF OFF ON ON 3 OFF ON OFF...

Page 28: ...ACP 1000MB User Manual 20...

Page 29: ...Appendix A A Exploded Diagram...

Page 30: ...ACP 1000MB User Manual 22 A 1 Exploded Diagram Figure A 1 Exploded diagram...

Page 31: ...Appendix B B Motherboard Options...

Page 32: ...ech ATX motherboards described below Contact your local sales representative for more detailed information Table B 1 ATX motherboard options Model Name Bus PCI PCI ISA ISA AGP SATA AIMB 750 2 PCI X 64...

Page 33: ...25 ACP 1000MB User Manual Appendix B Motherboard Options...

Page 34: ...tions are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of...

Reviews: